Hantek DSO8102E / DSO8202E

Contents

Hantek DSO8102E / DSO8202E Handheld Oscilloscope User Manual

Model: DSO8102E / DSO8202E | Brand: Hantek

1. Introduction

The Hantek DSO8102E/DSO8202E is a powerful and portable 6-in-1 handheld device designed for a wide range of electronic testing and measurement applications. It integrates the functionalities of a digital oscilloscope, signal generator, spectrometer, and multimeter, making it an indispensable tool for engineers, technicians, and hobbyists. This manual will guide you through the proper use and maintenance of your device.

2. Safety Information

Please read and understand all safety instructions before operating the device. Failure to follow these instructions may result in electric shock, fire, or damage to the device.

  • Always use the provided power adapter and accessories.
  • Do not operate the device in wet or damp conditions.
  • Avoid exposing the device to extreme temperatures or direct sunlight.
  • Do not attempt to open or modify the device. Refer all servicing to qualified personnel.
  • Ensure proper grounding when connecting to circuits.
  • Verify voltage and current limits before making any measurements.

3. Package Contents

Carefully unpack your Hantek DSO8102E/DSO8202E and check for the following items:

Contents of the Hantek DSO8102E/DSO8202E package
Figure 3.1: Package contents, including the device, probes, power adapter, and carrying bag.
  • Hantek DSO8102E/DSO8202E Handheld Oscilloscope
  • Oscilloscope Probes (x2)
  • Multimeter Test Leads
  • Power Adapter
  • USB Cable
  • Carrying Bag
  • User Manual (this document)
  • Software CD (if applicable)

4. Device Overview

Familiarize yourself with the physical components and controls of your device.

4.1 Front Panel

Front view of the Hantek DSO8102E/DSO8202E Handheld Oscilloscope
Figure 4.1: Front view of the Hantek DSO8102E/DSO8202E, showing the display, control buttons, and input terminals.

The front panel features the main display, function buttons (F1-F4), navigation keys, mode selection buttons (SCOPE, DMM, AWG, MENU), and input terminals for oscilloscope probes and multimeter leads.

4.2 Rear Panel

Rear view of the Hantek DSO8102E/DSO8202E Handheld Oscilloscope
Figure 4.2: Rear view of the device, showing the battery compartment and ventilation.

The rear panel typically houses the battery compartment and ventilation slots. The kickstand for desktop use is also located here.

4.3 Side Panel

Side view of the Hantek DSO8102E/DSO8202E Handheld Oscilloscope, showing ports
Figure 4.3: Side view of the device, highlighting USB and power input ports.

The side panel includes the USB port for data transfer and firmware updates, and the power input jack for charging and external power supply.

5. Initial Setup

5.1 Powering On/Off

  1. To power on the device, press and hold the power button (usually located on the front panel) until the screen illuminates.
  2. To power off, press and hold the power button again until the device shuts down.
  3. Connect the power adapter to charge the internal battery or for continuous operation.

5.2 Connecting Probes

  1. For oscilloscope functions, connect the BNC end of the oscilloscope probes to the CH1 and CH2 input jacks on the front panel.
  2. Attach the ground clip of the probe to the circuit's ground.
  3. For multimeter functions, insert the test leads into the appropriate input terminals (e.g., VΩmA for voltage/resistance/current, COM for common ground).

6. Operating Instructions

The Hantek DSO8102E/DSO8202E offers multiple measurement modes. Use the mode selection buttons to switch between functions.

Angled view of the oscilloscope showing a waveform on the screen
Figure 6.1: Oscilloscope mode displaying a waveform.

6.1 Oscilloscope Mode

  1. Press the 'SCOPE' button to enter oscilloscope mode.
  2. Connect the probes to the circuit under test.
  3. Use the 'Vertical' (VOLTS/DIV) and 'Horizontal' (SEC/DIV) controls to adjust the waveform display.
  4. The 'Trigger' controls allow you to stabilize the waveform. Use 'AUTOSET' for automatic setup.
  5. Use the 'Measure' button to display automatic measurements like Vpp, Vrms, Frequency, etc.

6.2 Multimeter Mode

  1. Press the 'DMM' button to enter multimeter mode.
  2. Select the desired measurement function (Voltage, Current, Resistance, Capacitance, Diode, Continuity) using the function buttons or menu.
  3. Connect the test leads to the circuit according to the measurement type.
  4. Read the measurement value on the display.

6.3 Signal Generator Mode (AWG)

  1. Press the 'AWG' button to enter signal generator mode.
  2. Select the desired waveform type (Sine, Square, Triangle, etc.) and adjust parameters like frequency, amplitude, and offset using the controls.
  3. Connect the signal generator output to the circuit where the signal is needed.

6.4 Spectrometer Function

The spectrometer function allows for frequency domain analysis. Refer to the on-screen menu and specific instructions for detailed operation of this advanced feature.

6.5 Product Demonstration Video

Video 6.1: A demonstration of the Hantek Handheld Oscilloscope's various features and operational aspects.

7. Maintenance

7.1 Cleaning

Wipe the device with a soft, dry cloth. For stubborn dirt, use a slightly damp cloth with mild detergent. Do not use abrasive cleaners or solvents.

7.2 Storage

When not in use, store the device in its carrying bag in a cool, dry place away from direct sunlight and extreme temperatures. Ensure the device is powered off before storage.

7.3 Battery Care

Although the battery is not demountable, it is important to charge the device regularly to maintain battery health. Avoid completely discharging the battery for extended periods.

8. Troubleshooting

ProblemPossible CauseSolution
Device does not power onLow battery or power adapter issueConnect to power adapter and charge. Ensure power adapter is working.
No waveform displayed in oscilloscope modeProbes not connected correctly, signal too small/large, or trigger settings incorrectCheck probe connections. Adjust VOLTS/DIV and SEC/DIV. Use 'AUTOSET'.
Multimeter readings are inaccurateIncorrect test lead connection, wrong measurement range, or faulty leadsVerify lead connections and selected function. Check test leads for damage.
Device freezes or becomes unresponsiveSoftware glitchPerform a hard reset by holding the power button for 10 seconds. If issue persists, check for firmware updates.

9. Specifications

FeatureSpecification
Brand NameHantek
Model NumberDSO8102E/DSO8202E
HANTEK ModelDSO8102E/DSO8202E
Band Width100-349MHz
Real Time Sampling Rate1GSa/S
Record Length2M
Max Waveform Capture Rate30,000wfm/s
Digital Channels2
Display Resolution640*480 Pixels
Display Size5.0 - 6.9 Inches
Battery IncludedNo
IS Battery DemountableNo
PackageYes
CertificationCE
DIY SuppliesElectrical
OriginMainland China

10. User Tips

  • Many users appreciate the reliability and versatility of this device, often repurchasing it if their original unit is lost or damaged. Consider its value and take appropriate measures for safekeeping.
  • For optimal performance, ensure the device's firmware is up to date. Check the manufacturer's website for the latest versions.
  • Utilize the 'AUTOSET' function frequently in oscilloscope mode for quick and accurate waveform display, especially when dealing with unknown signals.

11. Warranty and Support

Hantek provides a standard warranty for its products. For specific warranty terms, technical support, or service inquiries, please refer to the official Hantek website or contact their customer service directly. Keep your purchase receipt as proof of purchase for warranty claims.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.