1. Introduction
The Hti HT-18 is a portable thermal imaging camera designed for various applications, including electronic manufacturing, energy auditing, fire fighting, medical treatment, and agriculture. It features a 3.2-inch full-color screen, a 220x160 infrared resolution, and a 0.3 million pixel visible light camera for detailed image capture and analysis. This manual provides essential information for the safe and effective use of your device.
Video: Product overview demonstrating the Hti HT-18 Thermal Imaging Camera's features and use cases.

Image: Examples of Hti HT-18 Thermal Imaging Camera applications in electronic manufacturing, energy, fire fighting, medical treatment, and agriculture.
2. Safety Information
Please read and understand all safety warnings and instructions before using this product. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Do not point the camera directly at strong light sources (e.g., the sun, lasers) as this may damage the infrared sensor.
- Keep the device dry. Do not expose it to rain or moisture.
- Do not operate the device in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust.
- Use only the specified charging cable and power adapter.
- Do not attempt to open or modify the device. Refer all servicing to qualified personnel.
- Keep out of reach of children.
3. Package Contents and Device Components
3.1 Package Contents
Upon unpacking, please verify that all items listed below are present and in good condition:
- 1 x Hti HT-18 Thermal Imaging Camera
- 1 x Micro USB Cable
- 1 x User Manual
- 1 x Carry Pouch
- 1 x Carry Pouch Strap
- 1 x Cardboard Package Box

Image: Hti HT-18 Thermal Imaging Camera package contents.
3.2 Device Overview
Familiarize yourself with the main components and controls of the HT-18 camera:

Image: Hti HT-18 Thermal Imaging Camera with labeled components: protective cover, visible light camera, infrared imaging sensor, image capture key, On/Off key, Menu Key, Select Key, Enter Key, Navigation Key (Up, Down, Left, Right).
- Protective Cover: Covers the lenses when not in use.
- Visible Light Camera: Captures standard visual images.
- Infrared Imaging Sensor: Detects infrared radiation to create thermal images.
- Image Capture Key: Triggers image capture.
- On/Off Key: Powers the device on or off.
- Menu Key: Accesses the main menu.
- Select Key: Used to select options within menus.
- Enter Key: Confirms selections.
- Navigation Keys (Up, Down, Left, Right): Navigates through menu options and adjusts settings.

Image: Front view of the Hti HT-18 Thermal Imaging Camera with protective cover open.
4. Initial Setup
4.1 Charging the Device
The HT-18 camera is powered by built-in rechargeable 18650 batteries. Before first use, ensure the device is fully charged.
- Connect the Micro USB cable to the camera's USB port.
- Connect the other end of the USB cable to a suitable USB power adapter (not included) or a computer's USB port.
- The charging indicator will show the charging status.
- Once fully charged, disconnect the cable.
4.2 Powering On/Off
- To Power On: Press and hold the On/Off key until the screen illuminates.
- To Power Off: Press and hold the On/Off key until the screen turns off.
5. Operating Instructions
5.1 Basic Operation
Once powered on, the camera will display a live thermal image. Use the navigation keys to move the measurement spot on the screen.

Image: Hti HT-18 Thermal Imaging Camera with screen displaying a thermal image and labeled controls.
5.2 Menu Navigation and Settings
Press the Menu Key to access the device settings. Use the Navigation Keys to scroll through options and the Select Key to choose an option. Press Enter to confirm changes.

Image: Screenshots demonstrating Hti HT-18 functions: checking images, applying color palettes, measuring objects (emissivity settings), and time setting.
Key Menu Options:
- Color Palette: Choose from 5 types of palettes (Rainbow, Iron Red, Cold Color, Black & White, White & Black) to visualize temperature differences.
- Emissivity: Adjust the emissivity value (0.1 to 10.0) for accurate temperature measurement of different materials.
- Automatic Power-off Time: Set the device to automatically power off after 5 minutes, 20 minutes, or disable this feature.
- Time Setting: Adjust the device's internal clock.
- Image Check: Review captured images.

Image: Examples of different color palettes available on the Hti HT-18: Rainbow, Iron oxide red, Cold color, Black & white, White & black, and Visible light camera mode.
5.3 Capturing Images
To capture a thermal image, aim the camera at the target and press the Image Capture Key. Images are saved to the built-in 4GB SD card in JPG format.

Image: Thermal images captured by the Hti HT-18 showing a human palm, an industrial park, a human body, a thermos, and hand temperature.
5.4 Data Transfer
Captured images can be transferred to a computer or other devices via the Micro USB 2.0 cable.
- Connect the camera to your computer using the provided USB cable.
- The camera will appear as a removable storage device.
- Browse the device's storage to access and copy your images.

Image: Hti HT-18 Thermal Imaging Camera connected to a computer via Micro USB for data transfer.
6. Maintenance
6.1 Cleaning
- Wipe the device body with a soft, damp cloth. Do not use abrasive cleaners or solvents.
- For the lens, use a lens cleaning cloth and specialized lens cleaning solution. Avoid touching the lens surface with bare hands.
6.2 Storage
- Store the camera in its carry pouch in a cool, dry place when not in use.
- Avoid extreme temperatures and high humidity.
- If storing for an extended period, ensure the battery is partially charged (around 50%) and recharge it every few months to maintain battery health.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Device does not power on | Low battery; Device malfunction | Charge the device fully. If problem persists, contact support. |
| Thermal image is blurry or unclear | Dirty lens; Out of focus range | Clean the infrared lens. Ensure the target is within the 0.5m shortest focus length. |
| Inaccurate temperature readings | Incorrect emissivity setting; Environmental factors | Adjust emissivity for the target material. Minimize environmental interference (e.g., reflections). |
| Cannot transfer images to computer | Faulty USB cable; Driver issue; Corrupted SD card | Try a different USB cable. Ensure the camera is powered on and connected correctly. Check computer's device manager. |
8. Specifications
| Feature | Specification |
|---|---|
| Display Screen | 3.2'' Full-Color Screen |
| Image Resolution (Infrared) | 220 × 160 |
| Visible Image Resolution | 0.3 Million Pixel |
| Thermal Sensitivity | 0.07°C |
| Temperature Measurement Range | -20~300°C (-4~572°F) |
| Measurement Precision | ±2.5°C or ±2.5% |
| Wavelength Coverage | 8-14um |
| Field Angle / Shortest Focus Length | 27°×35° / 0.5m |
| Emissivity | Adjustable from 0.1 to 10.0 |
| Focus Mode | Fixed |
| Image Capture Frequency | 8Hz |
| View Option | Full thermal and full visible vision with 25% step length |
| Storage Medium | Built-in 4GB SD Card |
| Image Format | JPG |
| Power Supply | Built-in Rechargeable 18650 Batteries |
| USB Interface | Micro USB 2.0 |
| Automatic Power-off Time | 5 minutes / 20 minutes / Not power off automatically |
| Dimensions (L×W×H) | 90 × 105 × 223mm |
| Weight | 289g |
| Work Temperature | 0°C to 50°C |
| Storage Temperature | -40°C to 80°C |
| Humidity | <85% RH |

Image: Side view of the Hti HT-18 Thermal Imaging Camera showing temperature range and resolution.

Image: Comparison of thermal imaging resolution between HT-19 (320x240) and HT-18 (220x160) models.
9. User Tips
- Adjust Emissivity: For the most accurate temperature readings, always adjust the emissivity setting to match the material you are inspecting. Different surfaces radiate heat differently.
- Utilize Hot/Cold Spot Tracking: The thermal point and cold point temperature marks on the display can help quickly identify the hottest and coldest areas in an image, guiding your inspection.
- Experiment with Color Palettes: Different color palettes can highlight temperature variations more effectively depending on the application. Try various palettes to find the one that best suits your current task.
- Regular Data Backup: Periodically transfer your images from the camera's internal storage to a computer to prevent data loss and free up space.
10. Warranty and Support
10.1 Warranty Information
The Hti HT-18 Thermal Imaging Camera comes with a 1-year warranty from the date of purchase, covering manufacturing defects. This warranty does not cover damage caused by misuse, accidents, unauthorized modifications, or normal wear and tear. Please retain your proof of purchase for warranty claims.
10.2 Technical Support
For technical assistance, troubleshooting, or service inquiries, please refer to the contact information provided by your retailer or the official Hti support channels. Ensure you have your product model and serial number ready when contacting support.