1. Product Overview
The TEKIVI 6839C is a high-precision LCD digital display voltage and electricity indicator designed for universal use with ternary lithium, lithium iron, and lead-acid batteries. It provides real-time voltage, battery percentage, and temperature readings, making it an essential tool for monitoring battery status in various applications.

Figure 1: Front view of the TEKIVI 6839C meter displaying voltage, battery percentage, and temperature.
This meter features a high-definition color screen with a wide viewing angle for clear visibility. It is suitable for a wide range of DC voltage systems from 8V to 100V.
2. Specifications
2.1. Product Parameters
- Voltage Measurement Range: DC 8 - 100V
- Operating Current: ≤ 20mA
- Screen Type: Color LCD (wide viewing angle)
- Detection Accuracy: ± 1%
- Scan Speed: 1 scan/500ms
- Static Power Consumption: < 2mA
2.2. General Specifications
- DIY Supplies: Electrical
- Power Supply: DC
- Display Type: Digital Only
- Battery Included: No
- High-concerned chemical: None
- Origin: Mainland China
3. Setup and Installation
3.1. Package Contents
- TEKIVI 6839C Intelligent Electricity Meter
- Connecting Wires (pre-attached)
3.2. Wiring Instructions
The meter comes with two pre-attached wires for connection to your battery system:
- Red Wire: Connect to the positive (+) terminal of your DC power source/battery.
- Black Wire: Connect to the negative (-) terminal of your DC power source/battery.
Caution: Ensure correct polarity when connecting the wires to avoid damage to the device or battery system. Disconnect power before making any connections.

Figure 2: Rear view of the meter showing the connecting wires.
3.3. Mounting
The meter can be integrated into a panel or mounted in a suitable location. Refer to the dimensional drawings in Section 8 for precise cutout requirements if panel mounting.
4. Operating Instructions
4.1. Basic Operation
- Power On/Off: On the home page, short-press the power button (usually the single button on the right side) to turn the display on and off.
- Entering Setup Mode: Press and hold the SET button (the same single button) for 2 seconds to enter the setup mode.
4.2. Mode Setting Instructions
Once in setup mode, you can navigate through various menus to configure the meter for your specific battery type and preferences.
4.2.1. Ternary Lithium Battery Settings (Menu 1)
- From the main page, press and hold the button for 2 seconds to enter settings. The display will show "L-003" (default for 3 strings).
- On the "L-003" page, press and hold the button for 2 seconds; the value "03" will flash.
- Short-press the button to select the number of battery strings (from 03 to 22 strings).
- After selecting, press and hold the button for 2 seconds to confirm (the value will become solid).
- Press and hold the button for 2 seconds again to return to the main page (settings complete), or short-press to go to the next settings page.

Figure 3: Ternary Lithium Battery Setting (L-mode). (Illustrative product image)
4.2.2. Iron-Lithium Battery Settings (Menu 2)
- From the main page, press and hold the button for 2 seconds to enter settings. Short-press the button to switch to the "F-003" page (default for 3 strings).
- On the "F-003" page, press and hold the button for 2 seconds; the value "03" will flash.
- Short-press the button to select the number of battery strings (from 03 to 26 strings).
- After selecting, press and hold the button for 2 seconds to confirm (the value will become solid).
- Press and hold the button for 2 seconds again to return to the main page (settings complete), or short-press to go to the next settings page.

Figure 4: Iron-Lithium Battery Setting (F-mode). (Illustrative product image)
4.2.3. Lead-Acid Battery Settings (Menu 3)
- From the main page, press and hold the button for 2 seconds to enter settings. Short-press the button to switch to the "P-12" page (default for 12V).
- On the "P-12" page, press and hold the button for 2 seconds; the value "12" will flash.
- Short-press the button to select the battery voltage (12V, 24V, 36V, 48V, 60V, 72V, 84V).
- After selecting, press and hold the button for 2 seconds to confirm (the value will become solid).
- Press and hold the button for 2 seconds again to return to the main page (settings complete), or short-press to go to the next settings page.

Figure 5: Lead-Acid Battery Setting (P-mode). (Illustrative product image)
4.2.4. Custom Voltage Settings (Menu 4)
This mode allows setting custom high and low voltage thresholds (DC 8V to 100V) with power-off memory.
- From the main page, press and hold the button for 2 seconds to enter settings. Short-press the button to switch to the custom voltage setting page (display shows "VOL: 88.8V C-" and "88.8"). The top row is high voltage, bottom row is low voltage.
- Press and hold the button for 2 seconds; the first value (high voltage) will flash.
- Short-press the button to select the desired high voltage value.
- Press and hold the button for 2 seconds again; the high voltage value will become solid, and the second value (low voltage) will flash.
- Short-press the button to select the desired low voltage value.
- After setting both values, short-press the button to confirm and enter the next settings page, or press and hold for 2 seconds to return to the main page.

Figure 6: Custom Voltage Setting (C-mode). (Illustrative product image)
4.2.5. Backlight Settings (Menu 5)
The factory default backlight is always on.
- From the main page, press and hold the button for 2 seconds to enter settings. Short-press the button to switch to the "bL" page (display shows "00 SET bL").
- Press and hold the button for 2 seconds; "00" will flash.
- Short-press the button to select backlight duration: "00" (always on), 10, 20, 30, 40, 50, 60, 70, 80, or 90 seconds.
- After selecting, press and hold the button for 2 seconds to confirm (the value will become solid).
- Press and hold the button for 2 seconds again to return to the main page (settings complete), or short-press to go to the next settings page.

Figure 7: Backlight Setting (bL-mode). (Illustrative product image)
4.2.6. High and Low Pressure Alarm Settings (Menu 6)
Configurable high and low voltage alarms.
- From the main page, press and hold the button for 2 seconds to enter settings. Short-press the button to switch to the alarm settings page (display shows "VOL: 88.8V AL" and "88.8"). The top row is high pressure (voltage), bottom row is low pressure (voltage).
- Press and hold the button for 2 seconds; the first value (high voltage alarm) will flash.
- Short-press the button to select the desired high voltage alarm value.
- Press and hold the button for 2 seconds again; the high voltage alarm value will become solid, and the second value (low voltage alarm) will flash.
- Short-press the button to select the desired low voltage alarm value.
- After setting both values, short-press the button to confirm and enter the next settings page, or press and hold for 2 seconds to return to the main page.

Figure 8: High and Low Pressure Alarm Setting (AL-mode). (Illustrative product image)
4.2.7. Voltage Calibration Setting (Menu 7)
Important: This product is factory-calibrated. Non-professionals should NOT use this function. Unauthorized operation will affect voltage accuracy. Contact the manufacturer if calibration is required.
- From the main page, press and hold the button for 2 seconds to enter settings. Short-press the button to switch to the electronic calibration function page ("CL").
- On the "CL" page, press and hold the button for 2 seconds; the displayed voltage will flash.
- Press and hold the button for 2 seconds again to complete automatic calibration and return to the main page. Calibration is complete.

Figure 9: Voltage Calibration Setting (CL-mode). (Illustrative product image)
4.2.8. SOC Mode Setting (Menu 8)
Important: Users cannot set this function. Please contact the manufacturer for SOC mode configuration.
- From the main page, press and hold the button for 2 seconds to enter settings. Short-press the button to switch to the SOC settings page ("So").
- On the "So" page, press and hold the button for 2 seconds. Select "ON" or "OF" (OFF) on the right.
- Press and hold the button for 2 seconds to confirm.
- Press and hold the button for 2 seconds again to return to the main page (settings complete), or short-press to go to the next settings page.

Figure 10: SOC Mode Setting (So-mode) - OFF. (Illustrative product image)

Figure 11: SOC Mode Setting (So-mode) - ON. (Illustrative product image)
4.2.9. Restore Factory Settings (Menu 9)
Important: Non-professionals should NOT use this function, as it will restore all product parameters to factory defaults and may affect product use.
- From the main page, press and hold the button for 2 seconds to enter settings. Short-press the button to select the factory reset page ("rF").
- On the "rF" page, press and hold the button for 2 seconds. The three "8"s on the left will flash, then turn into three "0"s.
- Press and hold the button for 2 seconds to restore factory settings. The three "0"s will light up steadily, indicating the factory reset is complete.
- Press and hold the button for 2 seconds to return to the main page (settings complete), or short-press to go to the next settings page (Menu 1).

Figure 12: Factory Reset Setting (rF-mode). (Illustrative product image)
5. Maintenance
- Cleaning: Use a soft, dry cloth to clean the display and casing. Do not use abrasive cleaners or solvents.
- Environmental Conditions: Avoid exposing the device to extreme temperatures, direct sunlight, high humidity, or corrosive environments.
- Connections: Periodically check wiring connections to ensure they are secure and free from corrosion.
6. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| No display/Device not powering on | Incorrect wiring polarity, loose connections, power source outside voltage range, device fault. | Check red wire to positive, black wire to negative. Ensure connections are secure. Verify battery voltage is within 8-100V DC. |
| Incorrect voltage/percentage reading | Incorrect battery type/string setting, device fault. | Verify the meter is configured for the correct battery type (Ternary Lithium, Iron-Lithium, Lead-Acid) and number of strings/voltage. Avoid voltage calibration unless you are a professional. |
| Display flickering or unstable | Unstable power supply, loose connection. | Ensure power supply is stable. Check all wiring connections for tightness. |
7. User Tips
- Simple Installation: Users have noted the ease of installation. Ensure correct polarity for quick setup.
- Clear Display: The meter provides a clear and accurate display of charge level, voltage, and temperature.
- Compact Size: The device is surprisingly small, which can be beneficial for space-constrained applications. Handle with care during installation.
8. Dimensional Drawings
Below are the precise dimensions of the TEKIVI 6839C Intelligent Electricity Meter for mounting and integration purposes.

Figure 13: Dimensional drawing of the 6839C meter. Dimensions: 68.78mm (Length) x 38.8mm (Width) x 14.3mm (Height).
9. Product Video
Watch this video for a visual overview of the TEKIVI 6839C Intelligent Electricity Meter.
Video 1: TEKIVI 6839C Product Showcase.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your original point of purchase or the manufacturer directly. Please refer to the official user manual PDF for additional details: TEKIVI 6839C User Manual (PDF).