1. Introduction
This manual provides essential information for the safe and efficient use of your ZODOLAMP Reflector LED Spotlight. Please read this manual thoroughly before installation and operation, and keep it for future reference.
2. Important Safety Instructions
WARNING: Failure to follow these safety instructions may result in fire, electric shock, injury, or property damage.
- DANGER: The edges of the product may be sharp. Be careful not to scratch your hands during handling and installation.
- ATTENTION: Do not scratch your hands.
- Ensure all screws and other accessories are tightened securely before use.
- Always disconnect power before installing, cleaning, or servicing the fixture.
- Installation should be performed by a qualified electrician in accordance with local electrical codes.
- Do not operate the fixture if it is damaged.
- Keep away from flammable materials.
- This product is designed for outdoor use with an IP66 rating, but ensure all connections are properly sealed.
Manufacturer: Zhongshan Kuzhimi Technology Co., Ltd.
3. Package Contents
- 1 x ZODOLAMP Reflector LED Spotlight (selected wattage)
- Integrated mounting bracket
- (No other specific items mentioned, assume basic fixture)
4. Setup and Installation
The LED spotlight features an integrated adjustable bracket for versatile mounting.

Figure 4.1: Various installation methods including wall-mounted, ground-mounted, ceiling/suction-mounted, and high-pole mounted.
4.1 Mounting
The adjustable bracket allows for flexible positioning. Secure the bracket to a stable surface using appropriate hardware (not included) for your chosen installation method:
- Wall-mounted: Attach the bracket to a vertical surface.
- Ground-mounted: Position the fixture on a horizontal surface.
- Ceiling/Suction-mounted: Secure to an overhead structure.
- High-pole mounted: Attach to a pole for elevated lighting.

Figure 4.2: The integrated bracket can be adjusted to direct light as needed.
4.2 Wiring
Ensure power is OFF at the circuit breaker before proceeding with wiring. The fixture comes with a three-wire cable:
- Red wire: Connect to the Live (L) wire.
- Blue wire: Connect to the Neutral (N) wire.
- Yellow wire: Connect to the Ground (GND) wire.

Figure 4.3: Wiring connections: Red to Live, Blue to Neutral, Yellow to Ground. Ensure all connections are secure and waterproof.
After wiring, ensure all connections are properly insulated and sealed, especially for outdoor installations, to maintain the IP66 waterproof rating.
5. Operating Instructions
Once properly installed and wired, restore power to the circuit. The LED spotlight will illuminate. There are no complex controls; operation is typically managed via the main power switch of the circuit it is connected to.
6. Maintenance
- Cleaning: Periodically clean the tempered glass cover with a soft, damp cloth to ensure optimal light output. Do not use abrasive cleaners.
- Inspection: Regularly check the mounting hardware and wiring connections for any signs of wear, corrosion, or loosening.
- Waterproof Seal: Ensure the waterproof rubber plug and all seals are intact to maintain the IP66 rating.
7. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Light does not turn on | No power supply; Loose wiring; Faulty fixture | Check circuit breaker; Verify wiring connections; Contact support if fixture is faulty. |
| Light is dim or flickers | Insufficient power; Voltage fluctuation; Faulty LED chip | Ensure stable power supply; Check voltage; Contact support. |
| Actual wattage lower than stated | Product discrepancy; Power supply issues | Verify power supply voltage; Use a power meter to measure actual consumption; Contact seller/manufacturer. |
8. Specifications
| Feature | Specification |
|---|---|
| Brand | ZODOLAMP |
| Item Type | Flood Lights |
| Power Options | 50W, 100W, 200W, 300W, 400W, 500W |
| Voltage | 220 V AC (Note: Low-voltage 12-85V DC/AC variants may exist) |
| Power Source | AC |
| Light Source | LED bulbs (COB light source) |
| Luminous Flux | 60-249 Lumens (per COB, varies by wattage) |
| Light Color Options | Warm Light (3500K), White Light (6500K) |
| Protection Level | IP66 (Waterproof and Dustproof) |
| Material | Thickened Iron Shell, High-Transparency Tempered Glass Mask |
| Style | Contemporary |
| Certification | CE |
| Bulbs Included | Yes |
| Origin | Mainland China |
8.1 Dimensions (Approximate)
| Wattage | Height (cm) | Width (cm) |
|---|---|---|
| 50W | 15 | 20 |
| 100W | 18 | 25 |
| 200W | 22 | 32 |
| 300W | 26 | 35 |
| 400W | 30 | 43 |
| 500W | 31 | 46 |

Figure 8.1: Visual representation of dimensions for various wattage models.

Figure 8.2: Visual representation of dimensions for 400W and 500W models.
9. User Tips
- Verify Power Output: Some users have reported discrepancies between the stated wattage and actual power consumption. If precise power output is critical for your application, consider using a power meter to verify the actual wattage drawn by the fixture after installation.
- Optimal Placement: Utilize the adjustable bracket to fine-tune the light direction for optimal coverage and to minimize glare.

Figure 9.1: Example of energy monitoring data showing actual power consumption (e.g., 135W for a potentially higher-rated fixture).

Figure 9.2: Example of using a multimeter and clamp meter to measure voltage and current, which can be used to calculate actual power.
10. Warranty and Support
For warranty information, technical support, or service inquiries, please contact your seller or the manufacturer directly.
Manufacturer Contact:
- Zhongshan Kuzhimi Technology Co., Ltd.
- Tel: 86-17728378089
- Mail: 2481653770@qq.com
- Address: A309, Building 1, Jiapule Technology Park, No. 8, Qianjin 2nd Floor, Tanzhou Town, Zhongshan City, Guangdong Province, China