diymore Voltage Current Meter

Contents

Diymore DC 6-200V 20A Multi-Function Digital Voltage Current Meter

User Instruction Manual

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of your Diymore DC 6-200V 20A Multi-Function Digital Voltage Current Meter. This device is designed for precise measurement of electrical parameters in DC circuits, including voltage, current, power, energy consumption, time, and impedance. It also features alarm functions for overvoltage, undervoltage, and overload conditions.

For a more detailed guide, please refer to the official PDF manual: Diymore Voltage Current Meter PDF Manual

2. Safety Information

WARNING: Electrical shock hazard. Always exercise caution when working with electrical circuits.

  • Ensure the power supply is disconnected before installation or wiring.
  • This device is designed for DC circuits only. Do NOT connect to AC power.
  • Ensure positive and negative terminals are correctly identified and separated during wiring to prevent damage to the meter and connected equipment.
  • Installation should be performed by qualified personnel if you are unsure about electrical wiring.
  • Do not exceed the specified voltage and current ratings of the meter.

3. Features

  • Electrical parameter measurement function: Measures voltage, current, power, energy consumption, time, and impedance.
  • Voltage alarm function: Backlight and voltage flashing prompt when exceeding the set voltage alarm threshold (overvoltage/undervoltage settable).
  • Overload alarm function: Backlight and power flashing prompt when exceeding the set power alarm threshold.
  • Clearing function: Buttons for clearing power and time data.
  • Power failure data saving function: Retains measured data even after power loss.
  • Backlight function: Adjustable backlight for improved visibility.

4. Specifications

Parameter Value
Measuring Voltage DC 6-200V
Measuring Current 0-20A
Measuring Power 0-4KW
Measured Energy Consumption 0-99999KW
On Load Timing 0-999 hours (zero overflow)
Measuring Impedance 0-999 Ω (out of range display '---')
Overload Alarm Settable
Voltage Alarm Overvoltage and undervoltage can be set
Wiring Type Fence terminal
Installation Method Embedded
Module Size (L*W*H) 68mm * 68mm * 22mm
Product Net Weight 58g
Panel Opening (L*W) 63mm * 63mm

5. Package Contents

The package includes:

  • Monitor x1 (Diymore DC 6-200V 20A Multi-Function Digital Voltage Current Meter)

6. Setup and Installation

The meter is designed for embedded installation. Ensure you have a panel opening of 63mm x 63mm for mounting.

6.1 Physical Dimensions

Front view of the meter with screen dimensions
Figure 1: Front view with screen dimensions (e.g., 41mm, 68mm, 48mm).
Back view of the meter with overall module dimensions
Figure 2: Back view with overall module dimensions (68mm x 68mm x 22mm).

6.2 Wiring Instructions

Important: When wiring, positive and negative terminals must be separated. AC power cannot be input to this device.

Wiring diagram on the back of the meter
Figure 3: Wiring diagram on the back of the meter.

Connect the meter using the fence terminals on the back as follows:

Internal circuit board with connected wires showing input and output connections
Figure 4: Example of internal wiring connections.
  1. Input Positive (DC 6-200V): Connect the positive terminal of your DC power source (within 6-200V) to the designated input positive terminal on the meter.
  2. Input Negative: Connect the negative terminal of your DC power source to the designated input negative terminal.
  3. Output Positive: Connect the positive terminal of your load to the designated output positive terminal.
  4. Output Negative: Connect the negative terminal of your load to the designated output negative terminal.

Ensure all connections are secure and properly insulated.

7. Operating Instructions

The meter features a single button for various operations and settings.

7.1 Key Functions

  1. Short Press: Briefly press the key to switch between display modes for power, energy consumption, time, and impedance.
  2. Double Quick Press: Quickly press the key twice to turn the backlight on or off.
  3. Press and Hold (6 seconds): Press and hold the key for 6 seconds to enter the setting mode.
  4. Press and Hold (3 seconds, in setting mode): Press and hold the key for 3 seconds to move to the next setting group.
  5. Press and Hold (2 seconds, in setting group): Hold the key for 2 seconds within a setting group to automatically jump to the next item within that group.
  6. Automatic Exit: If no operation is performed for 10 seconds in setting mode, the meter will automatically exit and save the current settings.

7.2 Display Modes

The meter cycles through different display modes with a short press of the button:

Meter display showing Voltage, Current, and Time (H:M)
Figure 5: Displaying Voltage (V), Current (A), and Time (H:M).
Meter display showing Voltage, Current, and Power (W)
Figure 6: Displaying Voltage (V), Current (A), and Power (W).
Meter display showing Voltage, Current, and Energy Consumption (W/h)
Figure 7: Displaying Voltage (V), Current (A), and Energy Consumption (W/h).

Examples of live measurements:

Live measurement example showing 11.6V, 2.769A, 32.12W
Figure 8: Live measurement example (11.6V, 2.769A, 32.12W).
Live measurement example showing 50.6V, 1.031A, 2W/h
Figure 9: Live measurement example (50.6V, 1.031A, 2W/h).
Live measurement example showing 36.1V, 1.010A, 0W/h
Figure 10: Live measurement example (36.1V, 1.010A, 0W/h).

8. Maintenance

  • Keep the meter clean and free from dust and moisture.
  • Avoid exposing the device to extreme temperatures or direct sunlight.
  • Do not use abrasive cleaners or solvents on the display or casing.
  • Regularly check wiring connections for tightness and signs of wear.

9. Troubleshooting

9.1 Display Flashing or Unresponsive

If the display is flashing uncontrollably or unresponsive, it might indicate an alarm condition (overvoltage, undervoltage, or overload) or a malfunction. Check the connected circuit for any conditions that might trigger an alarm. If the issue persists, ensure the wiring is correct and within the specified voltage/current range. Disconnect and reconnect power to reset the device.

9.2 Inaccurate Readings

Some users have reported inaccuracies in voltage and current readings, particularly at higher voltages (e.g., 2V error at 60V). This meter does not feature user-adjustable calibration. If precise measurements are critical, it is recommended to verify readings against a calibrated reference meter. Significant discrepancies may indicate a defective unit.

9.3 No Display

Ensure the power supply is connected correctly and within the DC 6-200V range. Check all wiring connections for continuity and proper polarity. If the issue persists, the unit may be faulty.

10. User Tips

  • This meter is generally considered practical and easy to set up for basic monitoring of voltage, current, and power.
  • The large LCD digits and illumination are beneficial for readability.
  • Be aware of potential measurement inaccuracies, especially if your application requires high precision. Consider external calibration if needed.
  • The meter does not measure capacitance and has a fixed voltage measurement range.
  • Ensure a stable DC power supply for optimal performance.

11. Frequently Asked Questions (FAQ)

Q: Can this meter be used with AC power?
A: No, this meter is strictly designed for DC 6-200V circuits. Connecting it to AC power will damage the device.
Q: How do I clear the energy consumption or time data?
A: The meter has a clearing function via its button. Refer to section 7.1 Key Functions for detailed steps on clearing power and time data.
Q: What happens if the voltage or current exceeds the specified limits?
A: The meter has built-in alarm functions. If the voltage or power exceeds the settable thresholds, the backlight will flash to alert you. Exceeding the absolute maximum ratings (200V, 20A) can damage the device.
Q: Does the meter retain data after power is turned off?
A: Yes, it has a power failure data saving function, meaning measured data is retained.