Gaqqee H56CS

Contents

Gaqqee H56CS Digital Voltmeter User Manual

Model: H56CS

1. Introduction

The Gaqqee H56CS Digital Voltmeter is a versatile battery coulometer designed for accurate, bi-directional detection of battery parameters. It provides real-time display of charge percentage, battery capacity (Ah), voltage (V), current (A), power (W), and charge/discharge time. This device is compatible with various battery types, including acid batteries, lithium ternary batteries, and lithium iron phosphate batteries, operating within a DC 9-100V range.

2. Safety Information

  • Ensure the power supply is within the specified DC 9-100V range.
  • Do not expose the device to extreme temperatures, moisture, or corrosive environments.
  • Handle with care to avoid physical damage.
  • All wiring should be performed by individuals familiar with electrical circuits to prevent short circuits or damage to the device and battery system.
  • Disconnect power before making any wiring changes.

3. Package Contents

  • 1 x Gaqqee H56CS Digital Voltmeter (Coulometer)

4. Product Overview

The H56CS Digital Voltmeter features a clear LCD display with a green backlight, showing all essential battery parameters. It includes three control buttons for navigation and settings.

4.1. Device Components

Gaqqee H56CS Digital Voltmeter from multiple angles, showing front display and rear PCB

Image 4.1: Front and rear views of the H56CS Digital Voltmeter.

4.2. Panel Description and Display Elements

Diagram of H56CS display panel with labels for battery icons, current capacity, percentage capacity, voltage, current, power, remaining time, and button functions.

Image 4.2: Detailed view of the H56CS display panel and button functions.

  • Display Elements: Battery Icons, Current Capacity, Percentage Capacity, Voltage, Current, Power, Remaining Time.
  • Buttons:
    • Up Arrow (▲): Short press for 1 second to Disarm; Long press for 3 seconds for Capacity Full.
    • Down Arrow (▼): Short press for 1 second for Status page; Long press for 3 seconds for Zero capacity.
    • Gear Icon (⚙️): Short press for 1 second for Metering page; Long press for 3 seconds to enter the Menu.

4.3. Product Video Overview

Play video
Watch video online

Video 4.3: A brief overview of the H56CS Digital Voltmeter.

5. Setup

5.1. Mounting the Device

The H56CS coulometer is designed for easy installation using a snap fastener. You will need to cut a rectangular hole in your device panel according to the dimensions provided below. Insert the coulometer into the hole and press firmly until the snap fastener is securely tightened.

Diagram showing panel cutout dimensions for H56CS: 75mm width, 39mm height.

Image 5.1: Panel cutout dimensions for installation (Width: 75mm, Height: 39mm).

5.2. Wiring Method

Proper wiring is crucial for accurate measurement and safe operation. The coulometer must be connected in series with the negative circuit of your battery pack.

Wiring diagram for H56CS coulometer showing series connection to battery, load, and charger on the negative side, and PW+ to the positive side.

Image 5.2: Wiring diagram for the H56CS Digital Voltmeter.

  1. Connect the coulometer in series to the negative circuit of the battery pack. The GND terminal of the coulometer connects to the negative terminal of the battery pack. The I+ terminal connects to the negative terminal of the charging and discharging circuit (load/charger).
  2. Take a 0.3-0.75mm² wire. Connect one end to the positive terminal of the battery pack, and the other end to the coulometer's PW+ terminal.
  3. Double-check all connections to ensure there are no errors before applying power.

5.3. Shunt Variants

The H56CS comes with different built-in shunt capacities for various current requirements:

  • 20A Shunt: Suitable for lower current applications.
  • H56CS coulometer with a 20A built-in shunt.

    Image 5.3.1: H56CS with 20A built-in shunt.

  • 50A Shunt: A common choice for many battery systems.
  • H56CS coulometer with a 50A built-in shunt.

    Image 5.3.2: H56CS with 50A built-in shunt.

  • 100A Shunt: For higher current applications.
  • H56CS coulometer with a 100A built-in shunt.

    Image 5.3.3: H56CS with 100A built-in shunt.

6. Operating Instructions

6.1. Display Readings

The H56CS provides comprehensive real-time data on your battery's status:

Diagram showing the types of measurements the H56CS can display: Percentage of electricity, Battery Capacity (Ah), Battery Voltage (V), Current level (A), Power Level (W), and Charge and Discharge Time.

Image 6.1: Types of measurements displayed by the H56CS.

  • %: Percentage of electricity (State of Charge).
  • Ah: Battery Capacity (Ampere-hours).
  • V: Battery Voltage.
  • A: Current Level.
  • W: Power Level.
  • Time: Charge and Discharge Time.

6.2. Using the Settings Menu

To configure the coulometer for your specific battery, you will need to access and adjust settings via the menu.

Diagram showing the settings menu of the H56CS, with options for Effective Capacity, Full Capacity Voltage, Zero Capacity Voltage, and Over Voltage Alarm, along with button functions for navigation and modification.

Image 6.2: Settings menu interface and button controls.

  1. Enter Menu: Long press the ⚙️ (Gear Icon) button for three seconds.
  2. Select Line: Use the ▲ (Up Arrow) and ▼ (Down Arrow) buttons to move the cursor between setting lines.
  3. Modify Value: With the desired line selected, short press the ▲ button for one second to modify the setting value.
  4. Select Digits: While modifying, short press the ▼ button for one second to select between plus and minus digits.
  5. Save & Exit: Long press the ⚙️ (Gear Icon) button for three seconds to save changes and exit the menu.

Key Settings:

  • 01CA: Effective Capacity (Ah): Set the total rated capacity of your battery in Ampere-hours.
  • 02FU: Full Capacity Voltage (V): Set the voltage at which your battery is considered 100% full.
  • 03ZV: Zero Capacity Voltage (V): Set the voltage at which your battery is considered 0% capacity (low voltage cut-off).
  • 04OV: Over Voltage Alarm (V): Set the voltage threshold for an over-voltage alarm.

7. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures when not in use.
  • Inspection: Periodically check wiring connections for tightness and signs of wear.

8. Troubleshooting

  • No Display: Check if the PW+ and GND connections are secure and if the battery voltage is within the 9-100V operating range.
  • Incorrect Readings: Verify that the wiring is correct as per the diagram. Ensure that the capacity and voltage settings in the menu (01CA, 02FU, 03ZV) match your battery specifications.
  • Display Flickering: Check for stable power supply and secure connections.

9. Specifications

Table of technical parameters for H56CS coulometer including operating voltage, power consumption, accuracy, capacity range, current ranges, operating temperature, and dimensions.

Image 9.1: Detailed technical parameters of the H56CS Digital Voltmeter.

ParameterValueUnit
Operating VoltageDC 9-100V
Working Current (Backlight On)7.5mA
Working Current (Backlight Off)3.5mA
Sleeping Power Consumption300uA
Current Range0-20A / 0-50A / 0-100A (model dependent)A
Accuracy±1% (±1 word)
Capacity Range0-99999Ah
Display TypeLCD with Green Backlight
Operating Temperature-10 to 65℃
Working Humidity10-80%RH
Overall Dimension79 x 43 x 38mm
Opening Size76.5 x 39.5mm
Display Size49 x 24mm

10. User Tips

No specific user tips are available from provided reviews or Q&A content.

11. Warranty and Support

For warranty information and technical support, please refer to the seller's policies or contact the point of purchase. Keep your proof of purchase for any warranty claims.

12. Environmental Disposal

This product contains electronic components and should not be disposed of with household waste. Please dispose of it according to local regulations for electronic waste recycling.

© 2024 Gaqqee. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.