1. Introduction
The Gaqqee BT13 Coulomb Counter Digital Voltmeter is a versatile device designed for fully automatic charge and discharge management of batteries. It intelligently controls the battery charge and discharge process to extend battery life. Featuring bidirectional current detection, it accurately monitors charge and discharge current and displays real-time energy flow status. The device includes a full-view dedicated LCD display, supports serial communication, and adheres to the standard Modbus protocol. With wide voltage compatibility (DC 10-110V input), it is suitable for various battery types. A high-precision external clock crystal ensures accurate timekeeping and precise power statistics.
2. Safety Information
Please read and understand all safety instructions before operating the device. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- Ensure all connections are secure and correct before applying power.
- Do not exceed the specified voltage and current ratings of the device.
- Keep the device away from water, moisture, and extreme temperatures.
- Do not attempt to disassemble or modify the device. Refer all servicing to qualified personnel.
- Always use appropriate personal protective equipment when working with electrical circuits.
3. Package Contents
The package includes:
- BT13 Coulomb Counter Module x 1
4. Product Specifications

Figure 4.1: Product Specifications
| Parameter | Value |
|---|---|
| Brand Name | Gaqqee |
| Model Number | XY-BT13L |
| Battery Voltage Range | 10~110V DC |
| Adapter Input Voltage Range | 10~110V DC |
| Maximum Current | 10A / 30A (variant dependent) |
| Voltage Accuracy | ±0.5% + 1 word |
| Current Accuracy | ±0.5% + 3 words |
| Current Resolution | 0.01A |
| Voltage Resolution | 0.01V |
| Operating Temperature | -10~60°C |
| Certification | CE |
| DIY Supplies | Electrical |
| Display Type | Digital Only |
| Power Supply | DC |
| Power Source | DC |
| Battery Included | No |
| Data Record | No |
| High-concerned chemical | None |

Figure 4.2: Product Dimensions and Packaging
5. Setup and Wiring
Proper wiring is crucial for the correct operation of the BT13 Coulomb Counter. Ensure all connections are secure before powering on the device.

Figure 5.1: Wiring Diagram for Battery Charge and Discharge Management
Connection Steps:
- Connect the charger to the 'IN+' and 'IN-' terminals.
- Connect the rechargeable battery to the 'BT+' and 'BT-' terminals.
- Connect the load to the 'OUT+' and 'OUT-' terminals.
- Ensure all connections are securely fastened.
The device can also be connected to a TTL-to-RS485 module for RS485 communication or a WiFi module for networked remote control and unmanned operation via the Serial Communication Interface.
Video 5.1: Product demonstration showing connection and basic operation of the BT13 Coulomb Counter.
6. Operation
The BT13 Coulomb Counter features an intuitive LCD display and button controls for various operating modes and parameter settings.
6.1 Product Operation Interface Overview

Figure 6.1: Product Operation Interface Overview
Briefly press the SET button to switch the display content on the lower screen. The product supports displaying:
- Current (A): Charging current or discharging current.
- Power (W): Charging power or discharging power.
- Capacity (Ah): Real-time display of battery remaining capacity.
- Energy (Wh): Real-time display of battery remaining energy.
- Percentage (%): Relatively accurate remaining capacity percentage.
- Runtime (h): This parameter starts counting when the device exits pause mode, resets during mode switching, and can serve as one of the pause conditions (timer is not reset during pauses).
- Temperature (°C/°F): If an external temperature probe is connected, this parameter displays external temperature; otherwise, it displays internal circuit board temperature.
6.2 Operating Modes

Figure 6.2: Battery Charge and Discharge Flow Diagram

Figure 6.3: Operating Mode Description
Charging Mode:
- When in charging state, the charging relay closes, the charging icon flashes, and the battery capacity icon dynamically displays the charging process.
- Button Functions: Short-press STOP button for emergency stop. Long-press STOP button to force switch to discharge mode.
Discharge Mode:
- When in discharge state, the discharge relay closes, the discharge icon flashes, and the battery capacity icon dynamically displays the discharging process.
- Button Functions: Short-press STOP button for emergency stop. Long-press STOP button to force switch to charging mode.
UPS Mode Description:

Figure 6.4: UPS Mode Description
- In UPS mode, the charging relay and discharging relay remain simultaneously closed. The charger supplies power to both the battery (charging) and the load.
- When the battery is fully charged, the charging relay maintains connection.
- If AC power fails, the battery automatically powers the load until complete depletion.
- When AC power resumes, the system automatically restores charging while continuing to power the load.
- Note: This mode requires the charger's output power to exceed the sum of charging power and load power.
- Charging and discharging icons flashing simultaneously indicates UPS mode.
- Current Description in UPS Mode: The displayed current indicates the battery charging current. If the charger disconnects, the charging icon will flash rapidly, and the battery automatically powers the load, switching to battery discharge current.
- How to Enable/Disable UPS Mode: Long press the SET button to enter settings, set the FUC parameter to "UPS" to enable UPS mode; set to other values to disable UPS mode.
- UPS Mode Button Function: Short press the STOP button for emergency stop.
6.3 System Parameter Configuration
Short-press SET to cycle through adjustable parameters. Modify values using UP/DOWN buttons. For toggle-type parameters (---- indicates disabled), long-press STOP to enable/disable. Long-press SET to confirm settings and exit configuration mode.

Figure 6.5: System Parameter Configuration (CAP, FUC, LbP)
- CAP SET (Set Battery Full Capacity): If the battery capacity is known, set the specific value here. If unknown, the system automatically records the learned capacity after calibration.
- FUC SET (Charging Mode Operation): Select operating mode: 1. Charging mode (CH), 2. Discharging mode (dCH), 3. UPS uninterruptible power supply mode (UPS).
- LbP SET (Low Battery Alarm Threshold): When battery percentage falls below this parameter, audible/visual alarms activate, and the system switches to charging mode. (e.g., 5% triggers alarm and switches to charging).

Figure 6.6: System Parameter Configuration (dOP, FOP, LOP, POd)
- dOP SET (Turn-On Delay Time): After setting and enabling, the system enters a delay countdown during mode switching. Mode transition occurs after countdown reaches zero.
- FOP SET (Forced Turn-On Time): When enabled, the system enters forced conduction state during mode transitions and device startup. Prevents false triggering from voltage fluctuations.
- LOP SET (Cycle Threshold): One complete charge and discharge process is a cycle. The system counts completed cycles, triggers an LOP alarm when count matches LOP, clears count, opens relays, and stops operation.
- POd SET (Power-On Status Parameters): ON: Automatically operates in FUC-set mode upon power-on. OFF: Remains inactive (emergency stop state) after power-on.

Figure 6.7: System Parameter Configuration (bEP, Add, C-F, CLU)
- bEP SET (Buzzer Enable/Disable): ON: Turn on the buzzer. OFF: Turn off the buzzer (no key press sounds or alarm prompts).
- Add SET (ModBus Address Setting): Value range 1-247, default 001. Supports serial communication and standard Modbus protocol for networking via 485 or WiFi module.
- C-F SET (Temperature Unit Switch °C/°F): Select between Celsius (°C) and Fahrenheit (°F).
- CLU SET (Voltage Calibration): See section 7.1 for details.

Figure 6.8: System Parameter Configuration (CLA, ZERO, RET)
- CLA SET (Current Calibration): See section 7.2 for details.
- ZERO SET (Current Zero-Point Calibration): See section 7.3 for details.
- RET SET (Factory Reset): Press and hold STOP button to reset all parameters to factory defaults.
7. Calibration
To ensure accurate readings and proper operation, capacity and measurement calibration may be required.
7.1 Capacity Correction Mode
It is essential to correctly set the actual effective capacity of the battery. There are two methods:
Capacity Correction Mode - Unknown Capacity:

Figure 7.1: Capacity Correction Mode (Unknown Capacity)
- Step 1: To enter Capacity Correction Mode, ensure the charger, battery, and load are all properly connected.
- Step 2: Press the SET button briefly to switch the interface to the capacity parameter (Ah) interface.
- Step 3: Press and hold the UP button for more than 5 seconds to enter the Capacity Correction Mode.
Charging Phase:

Figure 7.2: Charging Phase during Capacity Correction
Charging ceases and the charging phase begins upon fulfillment of any of these conditions:
- Battery voltage > overvoltage protection threshold (if parameter is turned off, no detection is performed).
- Charging current < minimum current threshold (LAP) (LAP Off state, Default 20mA).
Upon completion of Capacity Correction, the system automatically records the capacity parameters.
To forcibly exit Capacity Correction mode during the process, press and hold the UP button for more than 5 seconds.
Capacity Correction Mode - Known Capacity:

Figure 7.3: Capacity Correction Mode (Known Capacity)
- Step 1: Press and hold the SET button for 2 seconds on the main UI to enter the settings interface.
- Step 2: Press the UP/DOWN buttons shortly to adjust the parameter value. Short-press STOP button to shift position.
- Step 3: After completing the capacity parameter settings, long-press the SET button for 2 seconds again to exit the settings interface. The parameters will be saved automatically.
7.2 Voltage Calibration (CLU)
- Short-circuit IN+ and BT+, and connect the battery (or power supply) to BT+ and BT-. Do not connect any load to OUT+ and OUT-.
- On the CLU interface, press and hold the STOP button to enter the voltage calibration interface.
- Use a high-precision multimeter to measure the voltage between BT+ and BT-. Enter the actual value into the second line of the LCD display using the UP/DOWN buttons. Press the STOP button briefly to shift the digits.
- Press and hold the STOP button again. The LCD will display "SUC", indicating that the calibration is complete.
7.3 Current Calibration (CLA)
- Connect the charger/battery to the IN+ and IN- terminals, and connect the load to the BT+ and BT- terminals. The OUT+ and OUT- terminals should remain unloaded.
- On the CLA interface, press and hold the STOP button to enter the current calibration interface.
- Connect a high-precision ammeter in series with the load (at the BT+ terminal), and enter the actual current value into the second line of the LCD display using the UP/DOWN buttons. Press the STOP button briefly to shift the digits.
- Press and hold the STOP button again. The LCD will display "SUC", indicating that the calibration is complete.
7.4 Current Zero-Point Calibration (ZERO)
- Connect the charger/battery to the IN+ and IN- terminals. Leave the BT+, BT-, OUT+, and OUT- terminals unconnected (floating).
- On the ZERO interface, press and hold the STOP button to enter the current calibration interface.
- Wait for the current parameter to stabilize at 0A.
- Press and hold the STOP button again. The LCD will display "SUC", indicating that the calibration is complete.
8. Maintenance
- Keep the device clean and dry. Avoid exposure to dust, dirt, and liquids.
- Do not use abrasive cleaners or solvents. Wipe with a soft, dry cloth.
- Store the device in a cool, dry place when not in use.
- Regularly check wiring connections for tightness and signs of wear.
9. Troubleshooting and Alarms
9.1 Charge/Discharge Mode Transition Alerts
The device evaluates transition conditions and notifies users when criteria are met. Alerts persist for 5 seconds before automatically clearing.

Figure 9.1: Charge/Discharge Mode Transition Alerts and Alarm Function
Display examples:
- OVP: Battery overvoltage condition met
- LVP: Battery undervoltage condition met
- LAP: Current threshold condition met
- OHP: OHP Time threshold condition met
- CAP: CAP Capacity threshold condition met
9.2 Alarm Function
When an alarm is triggered:
- The screen and alarm code flash.
- The buzzer sounds for 60 seconds.
- If multiple alarms occur simultaneously, only the highest priority alarm code is displayed.
Alarm Codes and Priority Ranking:
- 1-OCP: Overcurrent alarm
- 2-nbE: Battery not connected alarm
- 3-nCH: Charger not connected alarm
- 4-REV: Reverse current alarm: Current direction does not match the current mode
- 5-VOE: Voltage anomaly alarm: Triggered when battery voltage exceeds charger voltage during charging after relay activation
- 6-OTP: Device overtemperature alarm
- 7-ETP: External overtemperature alarm
- 8-LOP: Cycle threshold alarm
- 9-HFC: Relay high-frequency operation alarm (to prevent relay damage)
- 10-OVP: Battery overvoltage alarm
- 11-LVP: Battery undervoltage alarm
9.3 Protection Settings

Figure 9.2: Protection Settings (LVP, OVP, LAP, OCP)
- LVP SET (Under-Voltage Protection): When battery voltage drops below this parameter, audible/visual alarms activate, and the system automatically switches to charging mode. (e.g., if set to 22.0V, alarms trigger and system switches to charging mode when voltage falls below 22.0V).
- OVP SET (Over-Voltage Protection): When battery voltage exceeds this parameter, audible/visual alarms activate, and the system automatically switches to discharge mode. (e.g., if set to 24.8V, alarms trigger and system switches to discharge mode when voltage exceeds 24.8V).
- LAP SET (Current Threshold): When enabled in charge/discharge modes, the system automatically switches modes if current falls below LAP value. (Note: This parameter is inactive in UPS mode. e.g., if LAP=0.01A, system auto-switches modes when current <0.01A).
- OCP SET (Over-Current Protection): When charging/discharging current reaches the set OCP parameter, the relay will disconnect with audible/visual alarms. (e.g., if OCP=10.0A, relay trips when current reaches 10.0A, terminating charge/discharge with alarms).

Figure 9.3: Protection Settings (OHP, OTP, ETP)
- OHP SET (Runtime Protection): After setting the duration, the device accumulates operating time. Upon reaching the set time, it automatically switches charge/discharge modes. Minimum unit: 1 minute | Maximum setting: 99:59 (99 hours 59 minutes).
- OTP SET (Over-Temperature Protection °C or °F): If OTP is set to 90°C, when the PCB temperature near the relay reaches 90°C, the device will shut down for protection. After protection is triggered, the device will display an OTP alarm with audible and visual alerts. Press any button to cancel the alarm.
- ETP SET (External Over-Temperature Protection): If ETP is set to 60°C, when an external temperature probe (10K NTC probe) is connected and the temperature exceeds 60°C, the device will shut down for protection. After protection is triggered, the device will display an ETP alarm with audible and visual alerts. Press any button to cancel the alarm. Application Scenario: Attach the external temperature probe to the load (e.g., a battery). When the load temperature exceeds the set temperature, the output will shut down for protection, effectively preventing the load from overheating and burning out.
10. User Tips
- This module is highly versatile, suitable not only for controlling battery charging but also for comprehensive battery testing and as an energy storage controller.
- Ensure all connections are robust and secure for reliable performance.
- Familiarize yourself with the various display modes by briefly pressing the SET button to monitor different parameters like power, capacity, and temperature.
11. Warranty and Support
For warranty information and technical support, please contact your retailer or the manufacturer directly. Keep your purchase receipt as proof of purchase.
For a detailed user manual, please refer to the official PDF document: User manual (PDF)