SUOER SMP-4860

Contents

SUOER SMP-4860 MPPT Solar Charge Controller User Manual

Model: SMP-4860 | Brand: SUOER

1. Introduction

This manual provides detailed instructions for the installation, operation, and maintenance of the SUOER SMP-4860 MPPT Solar Charge Controller. The SMP-4860 is designed for efficient solar power management in 12V, 24V, and 48V systems, featuring advanced Maximum Power Point Tracking (MPPT) technology for optimal energy harvesting. It includes an LCD display for real-time monitoring and supports various battery types.

SUOER SMP-4860 MPPT Solar Charge Controller banner highlighting 60A, 99.9% MPPT tracking efficiency, auto battery voltage identification, multi-battery compatibility, and optional WiFi support.

SUOER SMP-4860 MPPT Solar Charge Controller with key features.

2. Safety Information

Please read all safety instructions carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.

  • Ensure all wiring is performed by qualified personnel.
  • Always disconnect power from the solar panels and battery before installing or servicing the controller.
  • Use appropriate tools and wear protective gear during installation.
  • Do not disassemble or attempt to repair the controller yourself. Contact qualified service personnel.
  • Ensure proper ventilation around the controller to prevent overheating.
  • Keep the controller away from flammable materials, moisture, and corrosive substances.
  • Verify correct polarity for all connections (solar panel, battery, load) to prevent damage.

3. Product Overview

3.1 Key Features

  • Advanced MPPT (Maximum Power Point Tracking) technology with >99% tracking efficiency.
  • Automatic identification of 12V/24V/48V system voltage.
  • Three-stage charging method: Constant Current (MPPT), Equalizing, and Float Charging.
  • Supports various battery types: Lead-acid, LiFePo4, Ternary Lithium, and User-Defined.
  • Integrated LCD display with backlight for real-time monitoring of system status.
  • Clock timing function, light control mode, and time control mode for load management.
  • Comprehensive protection features: Short Circuit, Over Discharger, Over Voltage, Over Charge, Over Temperature, and Solar Panel Reverse Polarity Protection.
  • Efficient fan cooling for good heat dissipation and low noise operation.
  • Communication methods: RS232, RS485, and optional WiFi support.
  • Protective level: IP21.

3.2 Components

Top and rear view of the SUOER SMP-4860 MPPT Solar Charge Controller, showing the LCD display, control buttons, solar panel terminals, battery terminals, DC load terminals, WiFi/RS232/RS485 port, and cooling fan.

Front and rear view of the controller with labeled connection points.

  • LCD Display: Shows system status, parameters, and settings.
  • Control Buttons: ESC (Escape/Back), < (Left/Down), > (Right/Up), OK (Confirm/Enter).
  • Solar Panel Terminals (+/-): Connect to your solar photovoltaic array.
  • Battery Terminals (+/-): Connect to your battery bank.
  • DC LOAD Terminals (+/-): Connect to your DC loads.
  • Communication Port: For WiFi (optional), RS232, or RS485 connections.
  • Cooling Fan: Located at the rear for heat dissipation.

4. Specifications

ParameterDescription/Value
ModelSMP-4860
Charging ModeMPPT automatic maximum power point tracking
Charging MethodThree stages: Constant Current (MPPT), Equalizing, Float Charging
System TypeAutomatic recognition/Manual setting (12V/24V/48V)
System Identification Voltage Range (12V)DC8V-DC16V
System Identification Voltage Range (24V)DC16V-DC32V
System Identification Voltage Range (48V)DC32V-DC64V
Quiescent Dissipation<5W
Max Conversion Efficiency>95.5%
Photovoltaic Module Utilization Ratio<99.9%
MPPT Working Voltage Range (12V)DC18V-DC150V
MPPT Working Voltage Range (24V)DC36V-DC150V
MPPT Working Voltage Range (48V)DC72V-DC150V
Maximum Photovoltaic Input Power (12V)900W
Maximum Photovoltaic Input Power (24V)1700W
Maximum Photovoltaic Input Power (48V)3400W
Optional Battery TypeLead acid battery, LiFePo4 battery, Ternary lithium battery or User-Defined
Rated Current60A
Input Low Voltage Protection (12V)DC14V
Input Low Voltage Protection (24V)DC28V
Input Low Voltage Protection (48V)DC32V
Input Low Voltage Recovery (Lead-acid, 12V)DC16V
Input Low Voltage Recovery (Lead-acid, 24V)DC32V
Input Low Voltage Recovery (Lead-acid, 48V)DC64V
Input Overvoltage ProtectionDC180V
Input Overvoltage RecoveryDC170V
Input Polarity Reverse ProtectionYES
Output Polarity Reverse ProtectionYES
High Temperature Protection70°C
Audible Noise<50dB
Heat Dissipation ModeFan cooling
Protective LevelIP21
Humidity0~90%RH
Height Above Sea Level0~3000m
Ambient Temperature-20°C~+40°C
Storage Temperature-40°C~+70°C
Product Dimensions (L x W x H)230mm x 197mm x 100mm
Diagram showing the dimensions of the SUOER SMP-4860 MPPT Solar Charge Controller: 230mm length, 197mm width, and 100mm height.

Product dimensions.

5. Setup

Follow these steps for safe and correct installation:

  1. Mounting: Choose a suitable location for the controller, ensuring adequate ventilation and protection from direct sunlight, moisture, and extreme temperatures.
  2. Wiring Sequence: Always connect the battery first, then the solar panels, and finally the DC load. Disconnect in the reverse order.
  3. Battery Connection:
    • Connect the positive (+) terminal of the battery to the battery positive terminal on the controller.
    • Connect the negative (-) terminal of the battery to the battery negative terminal on the controller.
    • Ensure secure connections. The controller will automatically detect the system voltage (12V/24V/48V).
  4. Solar Panel Connection:
    • Connect the positive (+) terminal of the solar panel array to the solar panel positive terminal on the controller.
    • Connect the negative (-) terminal of the solar panel array to the solar panel negative terminal on the controller.
    • Ensure the solar panel's open-circuit voltage (Voc) does not exceed the controller's maximum input voltage (150V).
    • Use copper cables with a cross-sectional area of at least 10 square millimeters for all main power connections to minimize voltage drop.
  5. DC Load Connection:
    • Connect the positive (+) terminal of your DC load to the DC LOAD positive terminal on the controller.
    • Connect the negative (-) terminal of your DC load to the DC LOAD negative terminal on the controller.
  6. Optional WiFi/Communication Module: If using, connect the WiFi module or RS232/RS485 communication cables to the designated port.
Wiring diagram for the SUOER SMP-4860 MPPT Solar Charge Controller, showing connections from solar panels to the controller, controller to battery, controller to DC load, and controller to an inverter for AC loads. Optional WiFi support is also indicated.

Typical product application and wiring diagram.

Image showing the SUOER SMP-4860 MPPT Solar Charge Controller compatible with Lead Acid, LiFePo4, and Ternary Lithium batteries, and also user-defined battery types. It automatically identifies 12V/24V/48V battery voltages.

Compatibility with various battery types.

6. Operating Instructions

6.1 LCD Display and Controls

Close-up of the SUOER SMP-4860 MPPT Solar Charge Controller's intelligent digital display, showing Date, Solar PV input voltage/current/power, Alarm status (green for no fault, red for fault), Settings options, Function Menu, Down, Up, Enter buttons, Load output voltage/current/power, Battery charge/discharge current/power/voltage, and Information options.

Real-time intelligent digital display interface.

The intelligent LCD screen provides real-time information and allows for system configuration:

  • Date: Current date.
  • Solar (PV input voltage, current and power): Displays real-time solar panel output.
  • Alarm: Indicates system status (green for no fault, red for fault).
  • Settings options: Access various configurable parameters.
  • Function Menu: Navigate through different functions.
  • Down (<): Used to decrease values or move left/down in menus.
  • Up (>): Used to increase values or move right/up in menus.
  • ESC: Escape or go back to the previous menu.
  • OK: Confirm selection or enter a menu.
  • Load (output voltage, current and power): Shows the power being drawn by connected DC loads.
  • Battery (charge and discharge current, power and battery voltage): Displays battery status and charging/discharging activity.
  • Information options: View detailed system information.

6.2 Load Control Modes

The controller supports various load control modes:

  • Light Control Mode: Automatically turns the load on/off based on ambient light levels.
  • Time Control Mode: Allows setting specific times for the load to turn on/off.
  • Clock Timing Function: Utilizes an internal clock for precise scheduling.

Refer to the on-screen settings options for configuring these modes according to your specific application needs.

7. Maintenance

Regular maintenance ensures optimal performance and longevity of your solar charge controller:

  • Cleaning: Periodically clean the exterior of the controller with a dry cloth. Do not use liquids or solvents.
  • Ventilation: Ensure the cooling fan and ventilation openings are free from dust and obstructions. A clear fan is crucial for good heat dissipation.
  • Connections: Regularly check all wiring connections for tightness and corrosion. Loose connections can cause overheating and damage.
  • Environmental Conditions: Ensure the controller operates within the specified ambient temperature range (-20°C to +40°C) and humidity (0-90%RH). Avoid exposing it to direct water spray, as its protective level is IP21 (protected against vertically falling water drops).
  • Firmware Updates: If available, check for and apply any firmware updates via the communication port (RS232/RS485/WiFi).

8. Troubleshooting

The controller is equipped with various protection functions and an alarm system to indicate potential issues.

8.1 Alarm Indications

The LCD display's alarm indicator will show:

  • Green: No fault detected, system operating normally.
  • Red: A fault has occurred. Check the display for specific error codes or messages.

8.2 Protection Functions

Icons representing the protection functions of the SUOER SMP-4860 MPPT Solar Charge Controller: Short Circuit Protection, Over Discharger Protection, Over Voltage Protection, Over Charge Protection, Over Temperature Protection, and Solar Panel Reverse Polarity Protection.

Built-in protection functions.

The controller automatically protects against:

  • Short Circuit Protection: Prevents damage from short circuits in the system.
  • Over Discharger Protection: Protects the battery from excessive discharge.
  • Over Voltage Protection: Safeguards against input or output overvoltage.
  • Over Charge Protection: Prevents battery overcharging.
  • Over Temperature Protection: Shuts down or reduces power if the internal temperature exceeds 70°C.
  • Solar Panel Reverse Polarity Protection: Protects the controller and system if solar panels are connected with incorrect polarity.
  • Output Polarity Reverse Protection: Protects the controller and system if loads are connected with incorrect polarity.

If a fault occurs, the controller will activate the relevant protection. Identify the cause of the fault, rectify it, and the controller should resume normal operation.

9. User Tips

  • Cable Sizing: Always use copper cables with a cross-sectional area of at least 10 square millimeters for main power connections (solar, battery, load) to ensure efficient power transfer and prevent overheating.
  • Battery Type Selection: Correctly configure the battery type in the controller's settings (Lead-acid, LiFePo4, Ternary Lithium, or User-Defined) to ensure proper charging algorithms and maximize battery lifespan.
  • Ventilation: Regularly check and clean the cooling fan and vents to maintain optimal heat dissipation, especially in warmer climates or enclosed spaces.
  • System Voltage: While the controller auto-identifies system voltage, double-check your battery bank voltage (12V, 24V, or 48V) matches the system configuration for best performance.

10. Warranty and Support

The SUOER SMP-4860 MPPT Solar Charge Controller comes with a one-year warranty from the date of purchase.

For technical assistance, troubleshooting, or warranty claims, please contact ElectroSmart Hub Store customer support. You can reach us via WhatsApp at: +86 18174421709. Our support team is available during working hours to help resolve any technical issues you may encounter.

Please have your product model number (SMP-4860) and purchase details ready when contacting support.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.