1. Introduction
The SONGGER S8601 and S8601A are portable indoor air quality monitors designed to accurately measure carbon dioxide (CO2) concentration in various enclosed environments. These devices also monitor ambient temperature and humidity, providing a comprehensive overview of your indoor air quality.
They are ideal for use in residential rooms, offices, classrooms, and agricultural facilities, contributing to a healthier and safer environment by helping to prevent the spread of infectious diseases and optimizing conditions for plant growth.
Model Differences:
- S8601: Equipped with a semiconductor CO2 sensor.
- S8601A: Features a non-dispersive infrared (NDIR) CO2 sensor, offering higher sensitivity and improved measurement accuracy.
The instrument provides clear visual and audible alarms when CO2 concentration exceeds preset limits, enabling users to take timely action to maintain good indoor air quality.

Figure 1: SONGGER S8601 Portable Carbon Dioxide Detector
2. Safety Information and Precautions
WARNING:
- High CO2 concentrations can cause drowsiness, headaches, or suffocation in extreme cases.
- This device is NOT a life safety device and must not replace certified gas detection or ventilation systems.
- Do not expose batteries to excessive heat, fire, or direct sunlight; incorrect battery installation may cause leakage or explosion.
- Keep out of reach of children.
General Precautions:
- This device is intended for indoor use only.
- Avoid exposure to water, high humidity, or direct sunlight.
- Do not use in environments with strong electromagnetic interference.
- Do not block the air inlet or ventilation openings.
- Do not disassemble or modify the device.
- If the display becomes unstable, replace the batteries.
- Remove batteries if the device will not be used for an extended period.
3. Package Contents
Please check the package for the following items:
- 1 x CO2 Detector (S8601 or S8601A model)
- 1 x User Manual
Note: Due to transportation regulations, 3x AAA batteries are NOT included in the shipment and must be prepared by the user.

Figure 2: Instrument Accessories (Batteries not included)
4. Specifications

Figure 3: Technical Parameters
| Feature | S8601 | S8601A |
|---|---|---|
| CO2 Sensor Type | Semiconductor Simulation | Nondispersive Infrared (NDIR) |
| Display | Dual-line LCD Display | |
| CO2 Measurement Range | 400 - 5000 ppm | |
| Temperature Range | -10°C to 70°C | |
| Humidity Range | 0 - 95% RH (non-condensing) | |
| CO2 Display Resolution | 1 ppm | |
| Preheating Time | 1 minute | |
| Response Time (T90) | < 120 seconds | |
| Operating Environment | -10°C to 50°C, <95% RH (no condensation) | |
| Storage Environment | -10°C to 60°C, max 70% RH (remove battery) | |
| Power Supply | 3 x 1.5V AAA Batteries (not included) | |
| Dimensions | 150mm x 52mm x 30mm | |
| Weight | 120g | |
| Backlight Indication | Green (Normal), Yellow (Elevated), Red (High/Alarm) | |
| Alarm Function | Audible alarm when CO2 exceeds 5000 ppm | |
| Over Range Indication | Display shows 'H1' with continuous beeping when above 5000 ppm | |
| Auto Power Off | Supported | |
5. Setup
5.1 Battery Installation
- Locate the battery compartment cover on the back of the device.
- Slide or unclip the cover to open the compartment.
- Insert 3 x 1.5V AAA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
- Close the battery compartment cover securely.

Figure 4: Battery Compartment (3x AAA Batteries)
5.2 Initial Placement
- Place the device in the area you wish to monitor.
- Allow the device to stabilize for several minutes (approximately 1 minute preheating time) before taking the first reading to ensure accuracy.
6. Operating Instructions

Figure 5: Product Information and Button Layout
- Power On/Off: Press the Power Button (
) to turn the device on. Press and hold the Power Button to turn it off. The device will automatically begin measuring after startup. - Display Reading: The LCD will display the current CO2 concentration (in ppm) on the main line and the ambient temperature (in °C or °F) and humidity (in %RH) on the secondary line.
- Temperature Unit Conversion: Press the °C/°F Button to switch the temperature display between Celsius and Fahrenheit.
- Data Hold Function: Press the HOLD Button to freeze the current readings on the display. Press it again to release and resume real-time measurement.
- Backlight Control: Press the Backlight Button (
) to toggle the backlight on/off. The backlight color (green, yellow, red) will automatically change based on CO2 levels. - Sound Alarm Control: Press the Sound Button (
) to enable or disable the audible alarm.
6.1 Understanding CO2 Levels and Backlight Indicators

Figure 6: CO2 Measurement Range and Backlight Prompts
| CO2 Measurement Range | Backlight Color / Prompt |
|---|---|
| 400 - 1000 ppm | Green backlight (Normal air quality) |
| 1000 - 2000 ppm | Yellow backlight (Elevated CO2, consider ventilation) |
| 2000 - 5000 ppm | Red backlight warning, alarm warning (High CO2, immediate ventilation needed) |
| > 5000 ppm | Red backlight, Panic alarm (Hazardous CO2 levels, evacuate and ventilate) |

Figure 7: Impact of CO2 Levels on Human Health
7. Maintenance
7.1 Cleaning
- Clean the exterior of the device with a soft, dry cloth.
- Do not use solvents, alcohol, or corrosive cleaning agents, as these can damage the device.
7.2 Storage
- Store the device in a dry and well-ventilated environment.
- Avoid extreme temperatures and humidity.
- If the device will not be used for an extended period, remove the batteries to prevent leakage and damage.
- Avoid mechanical shock or dropping the device.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Display shows 'H1' with continuous beeping | CO2 concentration exceeds 5000 ppm (over range) | Turn off the device and restart it to resume normal measurement. Ensure the area is well-ventilated. |
| Unstable or inaccurate readings | Low battery, device not stabilized, or strong electromagnetic interference | Replace batteries. Allow device to stabilize for a few minutes after power-on. Move device away from strong electronic devices. |
| Device does not power on | Batteries incorrectly installed or depleted | Check battery polarity. Replace with fresh batteries. |
9. User Tips
- Always ensure you have 3x AAA batteries ready, as they are not included in the package.
- For critical applications or higher accuracy requirements, consider the S8601A model with its NDIR sensor.
- If the device displays 'H1' and beeps continuously, it indicates extremely high CO2 levels. Immediately ventilate the area and restart the device.
- Periodically place the detector in a well-ventilated outdoor area for a few minutes to allow for self-calibration and maintain long-term accuracy.
10. Frequently Asked Questions (FAQ)
- Q1: Can this CO₂ detector be used in greenhouses or agricultural environments?
- A1: Yes, both S8601 and S8601A models are suitable for use in greenhouses, plant nurseries, and other agricultural settings to monitor air quality and optimize plant growth conditions.
- Q2: Does the device need calibration before use?
- A2: No calibration is required before initial use. The device comes factory-calibrated. However, for long-term accuracy, it's recommended to place the unit in a well-ventilated area periodically for self-calibration.
11. Warranty and Support
This product is manufactured under strict quality control standards. For any technical inquiries or support, please refer to the seller's contact information provided at the point of purchase.
This document is provided for product instruction purposes only and does not constitute legal advice. The seller is responsible for ensuring compliance with destination market regulations, including CE marking, EMC, and RoHS requirements.
Proper disposal: Follow WEEE Directive 2012/19/EU for electronic waste recycling. Dispose of used batteries according to Directive 2006/66/EC.