SONGGER S8601/S8601A

Contents

SONGGER S8601/S8601A Portable Carbon Dioxide Detector

User Instruction Manual

Model: S8601 / S8601A | Brand: SONGGER

1. Introduction

The SONGGER S8601 and S8601A are portable indoor air quality monitors designed to accurately measure carbon dioxide (CO2) concentration in various enclosed environments. These devices also monitor ambient temperature and humidity, providing a comprehensive overview of your indoor air quality.

They are ideal for use in residential rooms, offices, classrooms, and agricultural facilities, contributing to a healthier and safer environment by helping to prevent the spread of infectious diseases and optimizing conditions for plant growth.

Model Differences:

  • S8601: Equipped with a semiconductor CO2 sensor.
  • S8601A: Features a non-dispersive infrared (NDIR) CO2 sensor, offering higher sensitivity and improved measurement accuracy.

The instrument provides clear visual and audible alarms when CO2 concentration exceeds preset limits, enabling users to take timely action to maintain good indoor air quality.

SONGGER S8601 Portable Carbon Dioxide Detector showing CO2, temperature, and humidity readings

Figure 1: SONGGER S8601 Portable Carbon Dioxide Detector

2. Safety Information and Precautions

WARNING:

  • High CO2 concentrations can cause drowsiness, headaches, or suffocation in extreme cases.
  • This device is NOT a life safety device and must not replace certified gas detection or ventilation systems.
  • Do not expose batteries to excessive heat, fire, or direct sunlight; incorrect battery installation may cause leakage or explosion.
  • Keep out of reach of children.

General Precautions:

  • This device is intended for indoor use only.
  • Avoid exposure to water, high humidity, or direct sunlight.
  • Do not use in environments with strong electromagnetic interference.
  • Do not block the air inlet or ventilation openings.
  • Do not disassemble or modify the device.
  • If the display becomes unstable, replace the batteries.
  • Remove batteries if the device will not be used for an extended period.

3. Package Contents

Please check the package for the following items:

  • 1 x CO2 Detector (S8601 or S8601A model)
  • 1 x User Manual

Note: Due to transportation regulations, 3x AAA batteries are NOT included in the shipment and must be prepared by the user.

CO2 Detector S8601 with accessories including box and manual, noting batteries are not included

Figure 2: Instrument Accessories (Batteries not included)

4. Specifications

Technical Parameter table for S8601 and S8601A CO2 detectors

Figure 3: Technical Parameters

FeatureS8601S8601A
CO2 Sensor TypeSemiconductor SimulationNondispersive Infrared (NDIR)
DisplayDual-line LCD Display
CO2 Measurement Range400 - 5000 ppm
Temperature Range-10°C to 70°C
Humidity Range0 - 95% RH (non-condensing)
CO2 Display Resolution1 ppm
Preheating Time1 minute
Response Time (T90)< 120 seconds
Operating Environment-10°C to 50°C, <95% RH (no condensation)
Storage Environment-10°C to 60°C, max 70% RH (remove battery)
Power Supply3 x 1.5V AAA Batteries (not included)
Dimensions150mm x 52mm x 30mm
Weight120g
Backlight IndicationGreen (Normal), Yellow (Elevated), Red (High/Alarm)
Alarm FunctionAudible alarm when CO2 exceeds 5000 ppm
Over Range IndicationDisplay shows 'H1' with continuous beeping when above 5000 ppm
Auto Power OffSupported

5. Setup

5.1 Battery Installation

  1. Locate the battery compartment cover on the back of the device.
  2. Slide or unclip the cover to open the compartment.
  3. Insert 3 x 1.5V AAA batteries, ensuring correct polarity (+/-) as indicated inside the compartment.
  4. Close the battery compartment cover securely.
Back view of the CO2 detector with the battery compartment open, showing slots for three AAA batteries

Figure 4: Battery Compartment (3x AAA Batteries)

5.2 Initial Placement

  1. Place the device in the area you wish to monitor.
  2. Allow the device to stabilize for several minutes (approximately 1 minute preheating time) before taking the first reading to ensure accuracy.

6. Operating Instructions

Product information diagram showing numbered parts of the CO2 detector: Air inlet, Display, HOLD button, Backlight button, Power button, °C/°F button, Sound button.

Figure 5: Product Information and Button Layout

  1. Power On/Off: Press the Power Button (Power button icon) to turn the device on. Press and hold the Power Button to turn it off. The device will automatically begin measuring after startup.
  2. Display Reading: The LCD will display the current CO2 concentration (in ppm) on the main line and the ambient temperature (in °C or °F) and humidity (in %RH) on the secondary line.
  3. Temperature Unit Conversion: Press the °C/°F Button to switch the temperature display between Celsius and Fahrenheit.
  4. Data Hold Function: Press the HOLD Button to freeze the current readings on the display. Press it again to release and resume real-time measurement.
  5. Backlight Control: Press the Backlight Button (Backlight button icon) to toggle the backlight on/off. The backlight color (green, yellow, red) will automatically change based on CO2 levels.
  6. Sound Alarm Control: Press the Sound Button (Sound button icon) to enable or disable the audible alarm.

6.1 Understanding CO2 Levels and Backlight Indicators

Table showing CO2 measurement ranges and corresponding instrument sound/light prompts (Green, Yellow, Red)

Figure 6: CO2 Measurement Range and Backlight Prompts

CO2 Measurement RangeBacklight Color / Prompt
400 - 1000 ppmGreen backlight (Normal air quality)
1000 - 2000 ppmYellow backlight (Elevated CO2, consider ventilation)
2000 - 5000 ppmRed backlight warning, alarm warning (High CO2, immediate ventilation needed)
> 5000 ppmRed backlight, Panic alarm (Hazardous CO2 levels, evacuate and ventilate)
Chart illustrating the harm to human body after exceeding CO2 levels

Figure 7: Impact of CO2 Levels on Human Health

7. Maintenance

7.1 Cleaning

  • Clean the exterior of the device with a soft, dry cloth.
  • Do not use solvents, alcohol, or corrosive cleaning agents, as these can damage the device.

7.2 Storage

  • Store the device in a dry and well-ventilated environment.
  • Avoid extreme temperatures and humidity.
  • If the device will not be used for an extended period, remove the batteries to prevent leakage and damage.
  • Avoid mechanical shock or dropping the device.

8. Troubleshooting

ProblemPossible CauseSolution
Display shows 'H1' with continuous beepingCO2 concentration exceeds 5000 ppm (over range)Turn off the device and restart it to resume normal measurement. Ensure the area is well-ventilated.
Unstable or inaccurate readingsLow battery, device not stabilized, or strong electromagnetic interferenceReplace batteries. Allow device to stabilize for a few minutes after power-on. Move device away from strong electronic devices.
Device does not power onBatteries incorrectly installed or depletedCheck battery polarity. Replace with fresh batteries.

9. User Tips

  • Always ensure you have 3x AAA batteries ready, as they are not included in the package.
  • For critical applications or higher accuracy requirements, consider the S8601A model with its NDIR sensor.
  • If the device displays 'H1' and beeps continuously, it indicates extremely high CO2 levels. Immediately ventilate the area and restart the device.
  • Periodically place the detector in a well-ventilated outdoor area for a few minutes to allow for self-calibration and maintain long-term accuracy.

10. Frequently Asked Questions (FAQ)

Q1: Can this CO₂ detector be used in greenhouses or agricultural environments?
A1: Yes, both S8601 and S8601A models are suitable for use in greenhouses, plant nurseries, and other agricultural settings to monitor air quality and optimize plant growth conditions.
Q2: Does the device need calibration before use?
A2: No calibration is required before initial use. The device comes factory-calibrated. However, for long-term accuracy, it's recommended to place the unit in a well-ventilated area periodically for self-calibration.

11. Warranty and Support

This product is manufactured under strict quality control standards. For any technical inquiries or support, please refer to the seller's contact information provided at the point of purchase.

This document is provided for product instruction purposes only and does not constitute legal advice. The seller is responsible for ensuring compliance with destination market regulations, including CE marking, EMC, and RoHS requirements.

Proper disposal: Follow WEEE Directive 2012/19/EU for electronic waste recycling. Dispose of used batteries according to Directive 2006/66/EC.

© 2024 SONGGER. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.