1. Introduction

This manual provides detailed instructions for the safe and effective use of your WITRN C5, C4L, or C4 USB Voltage and Current Meter Tester. This device is designed for precise measurement and analysis of USB power delivery, supporting advanced protocols like PD3.1 and EPR, and enabling aging activation for various devices. Please read this manual thoroughly before operation.

2. Product Overview

2.1 Models

  • WITRN C5: Advanced model, available in blue (20bit) and grey (16bit) variants. Supports up to 48V and 480W.
  • WITRN C4L: Enhanced model, supports up to 48V and 280W.
  • WITRN C4: Standard model, supports up to 48V and 280W.

2.2 Key Features

  • Real-time Voltage (V), Current (A), and Power (W) display.
  • Support for PD3.1 (Power Delivery 3.1) protocol.
  • EPR (Extended Power Range) compatibility for higher voltage applications (up to 48V).
  • Aging Activation functionality.
  • Fast Charge Protocol Detection (e.g., UFCS).
  • Customizable display dashboard (on C4 models).
  • High current capacity, up to 13A.

2.3 Package Contents

  • WITRN USB Voltage and Current Meter Tester (C5, C4L, or C4 model)
  • User Manual (this document)
  • (Optional) EPR adapter (if purchased separately or included with specific models)

3. Setup

  1. Identify Ports: Locate the input (source) and output (load) USB-C ports on the tester.
  2. Connect Power Source: Plug the USB-C male connector of the WITRN tester into your power source (e.g., charger, power bank, computer USB port).
  3. Connect Device: Plug the device you wish to test (e.g., smartphone, laptop, USB-C accessory) into the USB-C female port of the WITRN tester.
  4. Power On: The tester will automatically power on and begin displaying measurements once connected to a power source.
WITRN C4 USB Tester connected to a power source and device, displaying voltage, current, and power.

Figure 3.1: Example of WITRN C4 USB Tester in operation.

4. Operating Instructions

4.1 Basic Measurements

Upon connection, the tester's display will show real-time data:

  • Voltage (V): Indicates the electrical potential difference.
  • Current (A): Shows the flow rate of electric charge.
  • Power (W): Represents the rate at which electrical energy is transferred.
  • Battery Percentage: (If applicable and supported by the connected device)
  • Time: Duration of the current measurement session.
WITRN C5 blue 20bit USB Tester displaying U 48.000V, I 10.000A, P 480.00W.

Figure 4.1: WITRN C5 display showing voltage, current, and power.

4.2 Advanced Features

  • PD3.1 & EPR: The tester automatically detects and displays information related to PD3.1 and EPR protocols when connected to compatible devices and chargers. This allows for testing higher voltage and power profiles.
  • Aging Activation: This feature is used for testing the stability and performance of power sources or devices under continuous load. Refer to the on-screen menu for specific activation steps.
  • Fast Charge Protocol Detection: The tester can identify various fast charging protocols (e.g., UFCS) used by the connected power source, providing insights into charging compatibility and performance.
  • Customizable Dashboard (C4 models): Certain models (like C4) allow users to customize the information displayed on the screen. Use the physical buttons on the device to navigate menus and adjust settings.
WITRN C4 USB Tester with customizable dashboard feature highlighted.

Figure 4.2: WITRN C4 with customizable dashboard and fast charge protocol detection.

5. Specifications

FeatureC4 / C4LC5
Max Voltage48V48V
Max Current13A13A
Max Power280W480W
Supported ProtocolsPD3.1, EPR, UFCS, etc.PD3.1, EPR, UFCS, etc.
Display TypeDigital LCD/OLEDDigital LCD/OLED
Bit Depth (C5 specific)N/A16bit (grey), 20bit (blue/red)

6. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use liquid cleaners or solvents.
  • Storage: Store the tester in a cool, dry place away from direct sunlight and extreme temperatures.
  • Handling: Avoid dropping the device or subjecting it to strong impacts, as this may damage internal components or the display.

7. Troubleshooting

  • No Display:
    • Ensure the tester is properly connected to a working power source.
    • Check if the power source is active and providing power.
  • Incorrect Readings:
    • Verify that both the power source and the load device are functioning correctly.
    • Ensure all connections are secure and free from debris.
    • Try using different cables or power sources to isolate the issue.
  • Device Not Charging:
    • Confirm that the power source is capable of charging the connected device.
    • Check the compatibility of the charging protocol between the source, tester, and device.

8. User Tips

  • For accurate measurements, ensure the tester is placed in a stable position and not subjected to excessive movement during testing.
  • When testing high-power devices, monitor the tester's temperature to ensure it remains within safe operating limits.
  • Regularly check for firmware updates from the manufacturer's official website to ensure optimal performance and access to new features.
  • Utilize the customizable dashboard feature (on applicable models) to prioritize the display of information most relevant to your testing needs.

9. Warranty and Support

For warranty information, technical support, or service inquiries, please refer to the contact information provided by your retailer or the manufacturer's official website. Keep your purchase receipt as proof of purchase for warranty claims.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?