1. Introduction
1.1 Purpose
This manual describes the assembly, installation, operation, and troubleshooting of the PowMr 3000W Hybrid Inverter. Please read this manual carefully before installation and operation. Keep this manual for future reference.
1.2 Features
- Pure sine wave inverter
- Configurable input voltage range for home appliances and personal computers via LCD setting
- Configurable battery charging current based on applications via LCD setting
- Configurable AC/Solar Charger priority via LCD setting
- Compatible with mains voltage or generator power
- Auto restart while AC is recovering
- Overload/Over temperature/Short circuit protection
- Smart battery charger design for optimized battery performance
- Cold start function
- WIFI/GPRS (Option)
- Can connect to lithium battery
1.3 Basic System Architecture
The PowMr Hybrid Inverter combines inverter, solar charger, and battery charger functions to provide uninterruptible power. It supports various applications including household, RV, yacht, and commercial setups.


2. Safety Instructions
WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.
- Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
- CAUTION: To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
- Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
- To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
- CAUTION: Only qualified personnel can install this device with battery.
- NEVER charge a frozen battery.
- For optimum operation, follow required specifications to select appropriate cable size.
- Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
- Strictly follow installation procedure when disconnecting AC or DC terminals.
- One piece of 150A fuse is provided as over-current protection for the battery supply.
- GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Comply with local requirements and regulations.
- NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
- Warning!! Only qualified service persons are able to service this device. If errors persist after following troubleshooting, send this inverter/charger back to local dealer or service center for maintenance.
3. Installation and Setup
3.1 Unpacking and Inspection
Before installation, inspect the unit. Ensure nothing inside the package is damaged. You should have received the following items:
- The unit x 1
- User manual x 1 (PDF available at PowMr User Manual PDF)
3.2 Preparation
Before connecting all wirings, remove the bottom cover by removing two screws.
3.3 Mounting the Unit
Consider the following points when selecting where to install:
- Do not mount the inverter on flammable construction materials.
- Mount on a solid surface.
- Install this inverter at eye level for LCD display readability.
- Allow a clearance of approx. 20 cm to the side and approx. 50 cm above and below the unit for proper air circulation.
- Ambient temperature should be between 0°C and 55°C.
- Adhere to the recommended vertical wall installation position.
- Keep other objects and surfaces as shown in diagrams to guarantee sufficient heat dissipation and space for wiring.
SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.
Install the unit by screwing two screws. M4 or M5 screws are recommended.

3.4 Battery Connection
CAUTION: Install a separate DC over-current protector or disconnect device between battery and inverter. All wiring must be performed by qualified personnel. Use appropriate cable for battery connection to reduce risk of injury.
Recommended battery cable size for 3.2KVA 24V model:
| Model | Wire Size | Cable (mm²) | Torque value (max) |
|---|---|---|---|
| 3.2KVA 24V | 1 x 6AWG | 14 | 2 Nm |
Steps for Battery Connection:
- Remove insulation sleeve 18 mm for positive and negative conductors.
- Suggest putting bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Connect all battery packs as per the diagram in the full PDF manual.
- Insert battery wires flatly into battery connectors of inverter. Tighten bolts with torque of 2 Nm in clockwise direction. Ensure correct polarity and tight connections.
WARNING: Shock Hazard. Installation must be performed with care due to high battery voltage in series.
CAUTION: Before making the final DC connection or closing DC breaker/disconnector, ensure positive (+) is connected to positive (+) and negative (-) to negative (-).
3.5 AC Input/Output Connection
CAUTION: Install a separate AC breaker between inverter and AC input power source. The recommended spec of AC breaker is 32A for 3.2KVA. Do NOT mis-connect input and output connectors. All wiring must be performed by qualified personnel.
Suggested cable requirement for AC wires (3.2KVA 24V model):
| Model | Gauge | Torque Value |
|---|---|---|
| 3.2KVA 24V | 12 AWG | 1.2 Nm |
Steps for AC Input/Output Connection:
- Before making AC input/output connection, open DC protector or disconnector first.
- Remove insulation sleeve 10mm for six conductors. Shorten phase L and neutral conductor N 3 mm.
- Insert AC input wires according to polarities indicated on terminal block and tighten screws. Connect PE protective conductor (yellow-green) first. (L: brown or black, N: blue).
- Then, insert AC output wires according to polarities indicated on terminal block and tighten screws. (L: brown or black, N: blue).
WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the unit.
3.6 PV Connection
CAUTION: Install a separate DC circuit breaker between inverter and PV modules. All wiring must be performed by qualified personnel.
Suggested cable requirement for PV module connection:
| Model | Wire Size | Torque value (max) |
|---|---|---|
| 3.2KVA 24V | 1x16AWG | 1.2 Nm |
PV Module Selection Parameters:
- Open circuit Voltage (Voc) of PV modules not exceeds max. PV array open circuit voltage of inverter (400Vdc).
- Open circuit Voltage (Voc) of PV modules should be higher than min. battery voltage.
- PV Array MPPT Voltage Range: 30Vdc-400Vdc.
Steps for PV Module Wire Connection:
- Remove insulation sleeve 10 mm for positive and negative conductors.
- Suggest putting bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
- Check correct polarity of wire connection from PV modules and PV input connectors. Connect positive pole (+) to positive pole (+) and negative pole (-) to negative pole (-) of PV input connector. Recommended tool: 4mm blade screwdriver.
3.7 Final Assembly
After connecting all wirings, put the bottom cover back by screwing four screws.
4. Operation
4.1 Power ON/OFF
Once the unit is properly installed and batteries are connected, press the On/Off switch (located on the bottom of the case) to turn on the unit.
4.2 Operation and Display Panel
The front panel includes three indicators, four function keys, and an LCD display, indicating operating status and input/output power information.
LED Indicator Messages:
- AC/INV (Green): Solid On = Output powered by utility (Line mode). Flashing = Output powered by battery or PV (Battery mode).
- CHG (Green): Solid On = Battery fully charged. Flashing = Battery is charging.
- FAULT (Red): Solid On = Fault occurs. Flashing = Warning condition occurs.
Function Keys:
- ESC: To exit setting mode.
- UP: To go to previous selection.
- DOWN: To go to next selection.
- ENTER: To confirm selection in setting mode or enter setting mode.
4.3 LCD Display Icons
The LCD display provides detailed information about input source, configuration, fault codes, output, and battery status. Refer to the full PDF manual for a comprehensive list of icons and their meanings (pages 10-12).
4.4 LCD Setting
Press and hold the ENTER button for 3 seconds to enter setting mode. Use "UP" or "DOWN" to select programs, then "ENTER" to confirm or "ESC" to exit. Key settings include:
- Program 01: Output source priority (Utility first, Solar first, SBU priority).
- Program 02: Maximum charging current (10A, 20A, 30A, 40A).
- Program 03: AC input voltage range (Appliances, UPS).
- Program 05: Battery type (AGM, Flooded, User-Defined).
- Program 09: Output frequency (50Hz/60Hz).
- Program 10: Output voltage (220V, 230V, 240V).
- Program 11: Maximum utility charging current (2A to 60A).
- Program 26: Bulk charging voltage.
- Program 27: Floating charging voltage.
- Program 29: Low DC cut-off voltage.
- Program 30: Battery equalization (Enable/Disable).
Refer to pages 12-19 of the full PDF manual for detailed LCD setting options and values.
4.5 Operating Mode Description
The inverter operates in various modes:
- Standby Mode / Power Saving Mode: No output, but can charge batteries.
- Fault Mode: Errors due to internal circuit issues or external reasons (e.g., over temperature, short circuit).
- Line Mode: Unit provides power from mains and charges battery.
- Battery Mode: Unit provides power from battery and PV.
Refer to pages 22-23 of the full PDF manual for detailed descriptions of each operating mode.
5. Maintenance
5.1 Clearance and Maintenance for Anti-Dust Kit (Optional)
Every inverter is installed with an anti-dust kit. This kit helps keep dust out and increases product reliability. The anti-dust kit should be cleaned from dust every one month.
Steps for Cleaning:
- Remove screws holding the dustproof case.
- Remove the dustproof case and take out the air filter foam.
- Clean the air filter foam and dustproof case.
- Re-assemble the dust-kit back to the inverter.
6. Troubleshooting
This section provides solutions for common issues. For persistent errors, contact a qualified service center.
| Problem | Explanation / Possible Cause | What to do |
|---|---|---|
| Unit shuts down automatically during startup | Battery voltage is too low (<1.91V/Cell) | 1. Re-charge battery. 2. Replace battery. |
| No response after power on | 1. Battery voltage is far too low (<1.4V/Cell). 2. Internal fuse tripped. | 1. Contact repair center for fuse replacement. 2. Re-charge battery. 3. Replace battery. |
| Mains exist but unit works in battery mode | Insufficient quality of AC power (Shore or Generator) | 1. Check if AC wires are too thin/long. 2. Check generator/input voltage range setting. |
| When unit is turned on, internal relay switches on/off repeatedly | Battery is disconnected | Check if battery wires are connected well. |
| Fault code 07 | Overload error. Inverter is overload 110% and time is up. | Reduce connected load by switching off some equipment. |
| Fault code 02 | Temperature of internal converter component is over 120°C. | Check if air flow is blocked or ambient temperature is too high. |
| Fault code 01 | Fan fault | Replace the fan. |
| Fault code 51, 52, 55 | Over current/surge, Bus voltage too low, Output voltage unbalanced. | Restart the unit. If error persists, return to repair center. |
Refer to pages 25-26 and 30-31 of the full PDF manual for a comprehensive list of fault codes, warning indicators, and troubleshooting steps.
7. Specifications
7.1 Line Mode Specifications (3.2KVA-24V)
- Input Voltage Waveform: Sinusoidal (utility or generator)
- Nominal Input Voltage: 230Vac
- Low Loss Voltage: 170Vac±7V (UPS); 90Vac±7V (Appliances)
- High Loss Voltage: 280Vac±7V
- Max AC Input Voltage: 300Vac
- Nominal Input Frequency: 50Hz / 60Hz (Auto detection)
- Efficiency (Line Mode): >95% (Rated R load, battery full charged)
- Transfer Time: 10ms typical (UPS); 20ms typical (Appliances)
7.2 Inverter Mode Specifications (3.2KVA-24V)
- Rated Output Power: 3200VA/3000W
- Output Voltage Waveform: Pure Sine Wave
- Output Voltage Regulation: 230Vac ±5%
- Output Frequency: 50Hz
- Peak Efficiency: 94%
- Nominal DC Input Voltage: 24 Vdc
- Cold Start Voltage: 23.0Vdc
- High DC Recovery Voltage: 32Vdc
- No Load Power Consumption: <35W
7.3 Charge Mode Specifications (3.2KVA-24V)
- Charging Algorithm: 3-Step
- AC Charging Current (Max): 60Amp (@VI/P=230Vac)
- Bulk Charging Voltage (Flooded Battery): 29.2V
- Floating Charging Voltage: 27Vdc
- Max. PV Array Power: 3000W
- Nominal PV Voltage: 240Vdc
- PV Array MPPT Voltage Range: 30~400Vdc
- Max. PV Array Open Circuit Voltage: 400Vdc
- Max Charging Current (AC charger plus solar charger): 80Amp
7.4 General Specifications
- Safety Certification: CE
- Operating Temperature Range: -10°C to 50°C
- Storage Temperature: -15°C ~ 60°C
- Humidity: 5% to 95% Relative Humidity (Non-condensing)
- Dimension (D*W*H), mm: 357X273X95
- Net Weight, kg: 4.8
Refer to pages 27-29 of the full PDF manual for complete specification tables.
8. User Tips
- Ensure all connections are secure and correctly polarized before powering on to prevent damage and ensure optimal performance.
- Regularly check the LCD display for operational status and any warning/fault codes to address issues promptly.
- For long-term reliability, adhere to the recommended cleaning schedule for the anti-dust kit.
- When setting up, carefully configure the battery type and charging parameters via the LCD settings to match your battery bank for optimal lifespan and performance.
9. Support and Contact Information
For technical support, warranty claims, or service, please contact PowMr directly.