Introduction

Thank you for choosing the Sovol SH02 Filament Dryer. This manual provides detailed instructions for the safe and efficient operation, maintenance, and troubleshooting of your new filament dryer. Please read this manual carefully before use to ensure optimal performance and longevity of the product.

Sovol SH02 Filament Dryer

The Sovol SH02 Filament Dryer, designed to keep your 3D printing filaments dry.

Safety Precautions

  • Please read this manual carefully before operating the device.
  • When not in use, always disconnect the power supply.
  • When heating, do not touch the top cover and the shell near the air outlet to prevent burns.
  • Do not allow children to operate without adult supervision.
  • Please use the dryer on a flat table or stable platform to prevent it from falling.
  • There are high-voltage parts within the equipment circuit. Do not disassemble or attempt to repair it yourself. If any abnormality occurs, please contact customer support.

Product Overview

Familiarize yourself with the components of your Sovol SH02 Filament Dryer:

Filament Dryer with sealing features

Diagram showing the filament outlet with PTFE seal and increasing sealing strip for great seal performance.

Filament Dryer with moisture outlet and PTFE tube insertion

Detailed view of the moisture outlet and filament outlets, which can be inserted with PTFE tubing.

Key Components:

  • Discharge Hole: For moisture release.
  • Ventilation Shaft: Aids in air circulation.
  • Snap Lock: Secures the top cover.
  • Screen: Displays parameters and settings.
  • Switch: Main power control.
  • Power Cord Interface: For connecting the power supply.
  • Filament Outlet PTFE Seal: Ensures a tight seal for filament.
  • Increasing Sealing Strip: Enhances drying performance by maintaining a dry environment.

Product Specifications

FeatureSpecification
Input VoltageUS Regulations: 100-120V 60Hz
National Standard, British Standard, European Standard: 200-240V 50Hz
Rated Power150W
Filament Diameter1.75mm / 2.85mm
Maximum Consumable CapacityTwo rolls of consumables, each ≤70mm (width) OR one single roll of consumables ≤150mm (width)
Display Humidity Range0-99%
Display Temperature Range0-99°C
Machine Size (L*W*H)249mm * 175mm * 283.5mm
Equipment Weight1.5KG
Dimensions and spool compatibility

Visual representation of the dryer's dimensions and compatibility with different spool sizes (200*70mm for two rolls, 200*150mm for one roll).

Setup Instructions

Step 1: Power Connection

  1. Plug one end of the power cord into a suitable power socket.
  2. Connect the other end of the power cord to the power interface of the drying box.
  3. Press the main power switch of the drying box. The standby start button on the right side of the screen will light up, indicating the dryer is in standby mode.

Step 2: Loading Filament

  1. Open the top cover of the dryer.
  2. Place the filament spool(s) inside the drying box. Ensure the filament is oriented correctly to avoid excessive friction between the filament and the filament hole.

Accessory Installation (PTFE Tube)

If you experience issues with filament feeding smoothly, you can add a PTFE tube:

PTFE tube installation diagram

Illustration of inserting PTFE tubes into the filament outlets.

  • Insert the sharp end of the PTFE tube into the dry box cover's filament outlet, approximately 15mm deep, to the proper position.
  • Pass the filament through the PTFE tube from the inside. This helps prevent the filament from contacting moisture in the air before printing and can improve print quality, especially for materials like ABS.
  • After use, remove and store the PTFE tube.

Operating Instructions

Control Panel Buttons:

Control panel buttons and screen display

Overview of the control panel, showing the display and button functions.

  • Standby Start Button (Power button icon): Powers on/off the drying process.
  • Setting Selection Key (Gear icon): Enters/exits setting mode and cycles through parameters.
  • Up Key (Up arrow icon): Increases values or moves selection up.
  • Down Key (Down arrow icon): Decreases values or moves selection down.

Screen Parameters:

  • Materials: Displays the currently selected consumable type.
  • Setting Temperature: Shows the user-set target temperature.
  • Current Temperature: Indicates the actual temperature inside the drying cavity.
  • Relative Humidity: Displays the current humidity level within the chamber.
  • Time: Shows the countdown for the drying process.

Starting the Drying Process:

  1. After connecting power and loading filament, press the Standby Start button (Power button icon) for 0.5 seconds.
  2. The screen information will illuminate, and the drying box will begin working according to the default parameters (e.g., PLA at 50°C for 8 hours).

Modifying Parameters:

  1. Click the Setting Selection Key (Gear icon) to enter the setting mode. A cursor (left arrow) will appear and flash periodically, indicating the currently selected parameter.
  2. Press the Setting Selection Key again to cycle through the parameters (Material, Setting Temperature, Time).
  3. Use the Up (Up arrow icon) and Down (Down arrow icon) keys to adjust the value of the selected parameter.
  4. To confirm settings, simply stop making adjustments. After 10 seconds of inactivity, the cursor will disappear, and the system will automatically save the new parameters and continue operation.

Note: While in setting mode, the heating block, fan, and timer continue to operate. If the time setting is changed, the timer will restart with the new value upon exiting the setting mode.

Consumable Drying Parameter Reference

The following table provides recommended drying temperatures and times for common filament types. These are general guidelines and may need adjustment based on specific filament brands and environmental conditions.

FilamentDrying TemperatureDrying Time
PLA50°C4-12h
PETG65°C4-8h
ABS60°C8-12h
TPU55°C4-8h
PVA50°C4-8h
ASA60°C8-12h
PA70°C≥12h
PP55°C4-8h
PC70°C8-12h

*When drying and printing PLA at the same time, a temperature setting of 45°C is recommended.

Maintenance

Replacement of Desiccant:

To maintain optimal drying performance, the desiccant inside the dryer should be replaced periodically.

Step 1: Opening the desiccant cover

1. Turn off the power and use your fingers to open the desiccant cover.

Step 2: Placing desiccant into the tank

2. Place the new desiccant into the tank.

Step 3: Aligning the cover flap

3. Place the flap of the cover against its notch.

Step 4: Installing the cover plate

4. Then install the cover plate securely.

Troubleshooting - Exception Codes

When an abnormality occurs, the self-monitoring program will detect it, forcibly shut down the PTC heating block and fan, sound a buzzer alarm, and display an abnormality code on the screen.

Example of N2 error code on screen

Example of an exception code (N2) displayed on the screen.

Common Exception Codes:

  • F2: The fan rotates abnormally, the fan power cord is disconnected, or the motherboard 12V power supply is unstable.
  • H1: The PTC heating block does not heat properly.
  • H2: The PTC heating block heats uncontrollably.
  • N1: NTC thermistor short circuit.
  • N2: NTC thermistor is blocked.
  • N3: NTC abnormal resistance value.

To exit the abnormal alarm state, press and hold the standby start button (Power button icon) for 0.5 seconds. The drying box will then enter the standby state.

Note: Please contact customer support immediately if an abnormal alarm occurs on the machine to find a solution.

User Tips for Optimal Performance

  • Ventilation: Some users find that leaving the lid slightly ajar, especially during the initial drying phase, can help humidity drop faster. Consider using a small prop or a 3D printed part to maintain a slight opening for the first couple of hours.
  • Fan Noise: The dryer's fan may produce a noticeable whining noise. If this is a concern, some users have successfully modified their units with silencer kits (e.g., 3D printed fan shrouds) to reduce noise levels.
  • Spool Compatibility: While the dryer can accommodate two standard rolls (up to 70mm width each) or one wide roll (up to 150mm width), be aware that some extra-wide spools might not fit.
  • Humidity Sensor Behavior: The humidity sensor might initially show a drop, then a slight increase as moisture is drawn out of the filament. This indicates the drying process is working effectively.
  • Long-term Storage: The dryer is designed to seal when not running and includes desiccant compartments, helping to keep filament dry for extended periods without constant operation.

Warranty and Support

For detailed warranty information, technical support, or to report any issues, please refer to the official Sovol website or contact their customer service. A comprehensive user manual in PDF format is available for download, which may contain additional information not covered in this quick guide.

You can view the official user manual (PDF) here.

Contact Information

Manufacturer: Shenzhen Liandianchuang Technology Co., Ltd

Official Website: sovol3d.com

Email: info@sovol3d.com

QR code for Sovol Official User Group

Join Sovol Official User Group

QR code for Sovol Official Website

Visit Sovol Official Website

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.