1. Introduction
Thank you for choosing the SANPKON Multifunctional Massager. This device is a professional physiotherapy massager designed to provide muscle stimulation and pain relief through Transcutaneous Electrical Nerve Stimulation (TENS) and Electrical Muscle Stimulation (EMS) technologies. Featuring 15 modes and 4 independent output channels, it offers a versatile and customizable experience for various body areas. Please read this manual thoroughly before use to ensure safe and effective operation.
2. Package Contents
Please check the box for the following items:
- 1x Multifunctional Massager Unit
- 1x Box
- 8x Electrode Pads (4 pairs)
- 4x Electrode Wires
- 1x USB Charging Cable
- 1x User Manual

The package includes: 1x Massager, 1x Box, 8x Electrode pads (4 pairs), 4x Electrode wires, 1x USB charging cable, 1x Manual.
3. Product Overview
The SANPKON Multifunctional Massager is designed for ease of use and effective therapy. It features a clear display and intuitive controls.

Detailed view of the massager's controls and display: Output Ports (A, B, C, D), Battery level display, Time display, Mode selection (M), Frequency selection (F), Time selection (T), Intensity increase (+), Intensity decrease (-), Screen display area, Mode display, Strength display.

The device features four fully isolated output channels (A, B, C, D) allowing simultaneous operation of multiple pads with independent intensity settings.
4. Setup Instructions
- Charge the Device: Before first use, ensure the device is fully charged using the provided USB charging cable. Connect the USB-C end to the device and the other end to a compatible USB power source.
- Connect Electrode Wires: Insert the electrode wires into the output ports (A, B, C, D) located at the top of the massager. Each port can accommodate one wire, which then splits to connect two electrode pads.
- Attach Electrode Pads: Connect the electrode pads to the ends of the electrode wires. Ensure the pads are clean and the adhesive is intact.
- Prepare Skin: Clean and dry the skin area where the electrode pads will be placed. Avoid placing pads over broken skin, open wounds, or areas with excessive hair.
- Apply Pads: Firmly press the electrode pads onto the skin. Ensure good contact for optimal conductivity.

The massager with electrode pads connected to the output channels, ready for application.
5. Operating Instructions
- Power On: Press the ON/OFF switch located on the side of the device to turn it on. The display will light up.
- Select Output Port: Press the A, B, C, or D button to select the desired output channel. Each channel can be controlled independently.
- Select Mode: Press the 'M' (Mode) button to cycle through the 15 available therapy modes. The selected mode will be displayed on the screen.
- Adjust Time: The default usage time is 20 minutes. To modify the time, press the 'T' (Time) button. The maximum adjustable time is 60 minutes.
- Adjust Frequency: The default setting is high frequency. To adjust the frequency, press the 'F' (Frequency) button.
- Adjust Intensity: After selecting the mode, gradually increase the intensity using the '+' button. Decrease intensity with the '-' button. The maximum intensity level is 30. Adjust until the massage feels comfortable and effective. For first-time users, start at the lowest intensity level.
- Power Off: After your session, press the ON/OFF switch to turn off the device.

The SANPKON Multifunctional Massager unit with connected electrode pads, ready for use.
This video provides a visual overview of the SANPKON Multifunctional Massager, showcasing its packaging, components, and basic operation.
6. Therapy Modes and Applications
The massager offers 15 distinct modes to target various needs and body parts:
- 1. Comprehensive
- 2. Massage
- 3. Acupuncture
- 4. Cupping
- 5. Clapping
- 6. Kneading
- 7. Gua Sha
- 8. Tuina
- 9. Facial
- 10. Neck
- 11. Shoulder
- 12. Back
- 13. Lumbar
- 14. Hand
- 15. Leg

The device screen showing the 15 available modes.
Example Application: Hand Function Rehabilitation

Application of the massager for hand function rehabilitation, stimulating extensor pollicis muscles to drive finger flexion and extension, hook/wrist lift, enhance muscle strength, and reduce muscle tone.
7. Safety Precautions
General Precautions:
- Discontinue use immediately if you experience any discomfort during operation.
- Remove all metal objects from your body before use.
- Device usage: 30 minutes per treatment, with at least 1 hour between sessions on the same area.
- For first-time users, start at the lowest intensity level and gradually increase after acclimatization.
- Unauthorized disassembly or modification of the product is strictly prohibited.
- Do not use the product while driving, sleeping, exercising, or bathing.
- After use, turn off the device and store safely, out of reach of children.
Contraindications:
The following individuals must NOT use this product:
- Individuals with pacemakers.
- Pregnant women.
- Patients with malignant tumors.
- Individuals with heart conditions.
- Individuals with epilepsy.
- Individuals with acute diseases or infectious diseases.
- Individuals with skin conditions or allergies in the treatment area.
Consult a healthcare professional before using this device if you have any pre-existing medical conditions or concerns.
8. Maintenance
- Cleaning: Wipe the device with a soft, damp cloth. Do not use abrasive cleaners or immerse the device in water.
- Electrode Pads: The electrode pads are reusable. Clean them gently with a damp cloth after each use and store them on their protective film to maintain adhesiveness. Replace pads when they lose their stickiness.
- Storage: Store the device and accessories in a cool, dry place, away from direct sunlight and extreme temperatures.
- Battery Care: To prolong battery life, avoid fully discharging the device frequently. Charge it regularly, even if not in use for extended periods.
9. Troubleshooting
- No Power: Ensure the device is charged. Check the ON/OFF switch is in the 'ON' position.
- No Sensation/Weak Sensation: Increase the intensity level gradually. Ensure electrode pads are firmly attached to clean, dry skin. Check that electrode wires are securely connected to both the device and the pads. Replace old or worn-out pads.
- Pads Not Sticking: Clean the pads with a damp cloth and allow them to air dry. Ensure the skin is clean and dry before application. Replace pads if adhesiveness is permanently lost.
- Irregular Sensation: Check all connections. Ensure pads are not overlapping or touching each other.
10. Specifications
| Parameter | Value |
|---|---|
| Product Name | Multifunctional Massager |
| Output Power | 5W |
| Battery Capacity | 2000mAh |
| Rated Current | 180mA |
| Output Voltage | 5V |
| Working Mode | 15 Modes |
| Intensity Levels | 30 Levels |
| Output Channels | 4 Channels |
| Dimensions (L x W x H) | 17.8cm x 11.4cm x 4.2cm (7.01in x 4.49in x 1.65in) |

The device measures 17.8cm (7.01in) in length and 11.4cm (4.49in) in width, with a thickness of 4.2cm (1.65in). It features a USB-C charging port and an ON/OFF switch. Product Parameters are also listed.
11. User Tips
- The device's ability to provide 4 different types of electric waves simultaneously across its 4 outputs is a key feature for comprehensive therapy.
- The screen comes with a protective film; consider keeping it on to prevent scratches and maintain screen clarity.
- Experiment with different modes and intensity levels to find what works best for your specific needs and comfort.
12. Frequently Asked Questions (FAQ)
- Q: How often can I use the massager?
- A: It is recommended to use the device for 30 minutes per treatment, with at least 1 hour between sessions on the same body area.
- Q: Are the electrode pads reusable?
- A: Yes, the electrode pads are reusable. Clean them gently after each use and store them on their protective film. Replace them when they lose their adhesiveness.
- Q: Can I use different modes on different output channels simultaneously?
- A: Yes, the device features 4 fully isolated output channels, allowing you to select different modes and intensity levels for each channel independently.
- Q: What should I do if the device is not working?
- A: First, ensure the device is charged and powered on. Check all cable connections and ensure the electrode pads are making good contact with your skin. If issues persist, refer to the Troubleshooting section.
13. Warranty and Support
For detailed warranty information and customer support, please refer to the official documentation provided with your purchase. A digital version of the user manual is also available for download:
If you encounter any issues or have questions not covered in this manual, please contact the seller or manufacturer's customer service for assistance.