1. Safety Information
Please read this manual carefully before installation and operation. Failure to follow these instructions may result in electric shock, fire, or other serious injury or damage.
- Installation and maintenance should only be performed by qualified electricians.
- Ensure the main power supply is disconnected before any installation or wiring work.
- Do not operate the device with wet hands or in damp environments.
- Verify all connections are secure and correctly wired according to the diagram.
- This device is designed for AC 220V/230V systems. Do not use it with other voltage systems.
- The device is rated for 1-63A. Do not exceed the maximum current rating.
2. Product Features
The SVP688W offers a comprehensive suite of features for smart electrical management:
- Remote Control: Turn ON/OFF the circuit breaker from anywhere using your smartphone.
- Real-time Monitoring: View current, voltage, leakage current, and total kWh consumption directly on the device's display or via the mobile app.
- Adjustable Protection Parameters:
- Over Voltage Protection: Adjustable from 240V-300V (default: 275V).
- Under Voltage Protection: Adjustable from 145V-210V (default: 175V).
- Over Current Protection: Adjustable from 1A-63A (default: 63A).
- Electric Leakage Protection: Adjustable from 10-99mA (default: 50mA). This feature can be turned off.
- Reconnect Time (Delay on Time): Adjustable from 10s-99s (default: 30s).
- Over Current and Leakage Protect Times: Adjustable from 1-30 (default: 5). This feature can be turned off.
- Over Temperature Protection: 10-85°C (settable only via the app).
- Multiple Timing Modes: Supports timing mode, countdown mode, and cycle timing.
- Clear Display: Features a colorful LED display for easy readability of parameters.
3. Specifications
| Parameter | Value |
|---|---|
| Brand Name | SINOTIMER |
| Model Number | SVP688W |
| Rated Supply Voltage | AC 230V |
| Rated Frequency | 50/60Hz |
| Operation Voltage Range | AC80V-400V (single phase) |
| Electric Current (>A) | 1-63A |
| Over Voltage (>U) Setting Range | 240V-300V (adjustable, default: 275V) |
| Under Voltage (<U) Setting Range | 145V-210V (adjustable, default: 175V) |
| Electric Leakage Protection | 10-99mA (off, default: 50mA, can be turned off) |
| Reconnect Time (Delay on Time) | 10s-99s (default: 30s) |
| Over Current & Leakage Protect Times | 1-30 (off, default: 5, can be turned off) |
| Over Temperature Protect | 10-85°C (App only) |
| Power Display Range | 0-99999.9kWh |
| Operating Temperature | -30°C to 70°C |
| Dimensions (L x W x H) | 85mm x 36mm x 65mm |
| Power Source | AC |
| Certification | CE, RoHS |
| Origin | Mainland China |
4. Package Contents
The package typically includes:
- 1 x SINOTIMER SVP688W Smart Circuit Breaker & Energy Protector
- 1 x User Manual (this document, or a printed version)
5. Installation
Professional installation by a qualified electrician is highly recommended.
5.1 Wiring Diagram
The device is a 2-pole (2P) circuit breaker. Connect the Live (L) and Neutral (N) wires to the "IN" terminals at the top and the load wires to the "OUT" terminals at the bottom. Ensure correct polarity.
- IN (Top Terminals): Connect the incoming Live (L) and Neutral (N) power supply.
- OUT (Bottom Terminals): Connect the outgoing Live (L) and Neutral (N) wires to your load (appliances/circuit).
5.2 Mounting
The device is designed for DIN rail mounting. Snap it onto a standard 35mm DIN rail within your electrical panel.
6. App Setup (Tuya Smart / Smart Life)
To utilize the smart features, connect your device to the Tuya Smart or Smart Life app:
- Download the App: Scan the QR codes below or search for "Smart Life" or "Tuya Smart" in Google Play Store (Android) or Apple App Store (iOS).
Instructions and QR codes for downloading the Smart Life/Tuya Smart app. - Create an Account: Open the app and create an account using your mobile number or email.
- Connect to Wi-Fi: Ensure your mobile phone is connected to a 2.4 GHz Wi-Fi network. The device does not support 5 GHz Wi-Fi.
- Add Device:
- In the app, click "+" in the upper right corner of the homepage or "Add Device".
- Select "Switch module (Wi-Fi)" from the "Energy" category.
- On the SVP688W device, long press the "WIFI" button for 5 seconds until the WIFI indicator starts to flash quickly.
- Follow the on-screen prompts in the app to pair the device. You may need to confirm the indicator is blinking rapidly and enter your 2.4 GHz Wi-Fi network password.
- Reset Device (if needed): If pairing fails, press and hold the "RESET" button (often the "SET" button or a dedicated reset button, refer to the device's physical layout) for 5 seconds until the indicator blinks. Then try adding the device again.
7. Device Operation
7.1 Display Functions
The device's colorful LED display shows real-time electrical parameters:
- V: Voltage (Volts)
- A: Current (Amperes)
- KW/h: Total Energy Consumption (Kilowatt-hours)
- mA: Leakage Current (Milliamperes)
7.2 Button Functions
The device features several buttons for local control and setting adjustments:
- PULSE: Indicator for energy pulse output.
- SET: Used to enter/confirm settings.
- ▲ (Up Arrow): Used to increase values or navigate menus.
- ▼ (Down Arrow): Used to decrease values or navigate menus.
- WIFI: Used for Wi-Fi pairing mode.
- Power Button (Red): Manual ON/OFF control for the circuit.
7.3 Parameter Settings (Local)
You can adjust protection parameters directly on the device:
- View Data: Press the ▲ or ▼ buttons to cycle through different displayed data (Voltage, Current, Leakage, etc.).
- Enter Setup Mode: Long press the SET button for 5 seconds. The display will change, indicating you are in setup mode.
- Select Parameter: Press the SET button repeatedly to cycle through the adjustable parameters (e.g., Over Voltage, Under Voltage, Over Current, Leakage Protection, Reconnect Time).
- Adjust Setting: Once the desired parameter is displayed, use the ▲ and ▼ buttons to adjust its value.
- Confirm Setting: Press the SET button again to confirm the adjusted value and move to the next parameter, or exit setup mode if no further adjustments are needed.
7.4 kWh Reset
To reset the total kWh energy consumption reading:
- Long press the SET button for 12 seconds.
- The screen will display "PASS".
- Use the ▲ and ▼ buttons to set the value to "222".
- Press the SET button to confirm the kWh reset.
8. User Tips
- The colorful LED screen is quite bright. Be aware that there might not be an option to dim or turn off the backlight directly on the device.
- The device's interface is in English, making it user-friendly for English speakers.
- A useful feature is its ability to display voltage even when the circuit is in the "off" position, which can be helpful for diagnostics.
- The mobile app integration (Tuya Smart/Smart Life) is convenient for remote monitoring and control, as well as for setting advanced parameters like over-temperature protection.
- For accurate readings and optimal performance, ensure all wiring connections are tight and secure.
9. Troubleshooting
| Problem | Possible Cause / Solution |
|---|---|
| Device not powering on. |
|
| Cannot connect to Wi-Fi / App. |
|
| Incorrect voltage/current readings. |
|
| Device trips frequently. |
|
| Device is not 2-pole (2P) as advertised. |
|
10. Frequently Asked Questions (FAQ)
- Q: Does this device measure and store instantaneous volts and amps, and does it act as a life saver (RCD)?
- A: Yes, the device measures and displays instantaneous voltage and current. It also calculates and stores total energy consumption (kWh). Furthermore, it acts as a protector against over/under voltage, over current, and leakage current (similar to an RCD function for leakage protection).
11. Warranty and Support
For warranty information and technical support, please refer to the documentation provided with your purchase or contact the SINOTIMER Official Store directly. You can also refer to the official PDF user manual for more detailed instructions: View User Manual (PDF).