1. Introduction
This manual provides detailed instructions for the safe and efficient operation, installation, and maintenance of your Sunster 8KW Diesel Air Heater. Please read this manual thoroughly before use and keep it for future reference.
1.1 Function
The Sunster Diesel Air Heater is designed to prevent damage to vehicles caused by sudden temperature drops, improve interior temperature, and preheat engine coolant to avoid low-temperature wear. It is conducive to thawing vehicle interiors, assisting with car starts, and defrosting car glass.
2. Safety Warnings
- Ensure proper ventilation when operating the heater to prevent carbon monoxide buildup.
- Do not place flammable materials near the exhaust pipe.
- The exhaust pipe must be straight and not angled upwards to ensure smooth exhaust.
- Exhaust from the exhaust pipe must be discharged outdoors.
- Ensure the power supply is 12V 15A or higher for 12V systems, or 24V 15A or higher for 24V systems.
- Do not bend the exhaust pipe too much as it can affect exhaust.
- Always check for firm installation and placement of the machine.
3. Package Contents
Upon unpacking, please verify that all items listed below are present and undamaged:

- Main Heater Unit
- Remote Control
- Air Filter
- Fixed Plate
- Air Outlet Pipe (Stretchable)
- Intake Pipe
- Exhaust Pipe
- User Manual (PDF available online: Sunster Diesel Heater User Manual PDF)
- Battery Power Cord
- Fixture Accessories Set
- AC-DC Adapter Power
- Silencer
4. Specifications
| Attribute | Value |
|---|---|
| Brand Name | Sunster |
| Item Type | Heating & Fans |
| Material | Aluminum + Plastic |
| Certification | RoHS, FCC, CE |
| Fuel Type | Diesel only |
| Heater Power | 8KW |
| Voltage | DC 12V & 24V; AC 110-240V |
| Power Adapter Input | AC110-240V 50-60Hz |
| Adjustable Temp. Range | 46.4°F - 96.8°F (8°C - 36°C) |
| Heater Working Temperature | -40°C ~ +20°C / -40°F ~ +68°F |
| Oil Pump Working Temperature | -40°C ~ +20°C / -40°F ~ +68°F |
| Air Outlet pipe diameter | 76mm (Stretchable air pipe) |
| Intake pipe diameter | 25mm |
| Exhaust pipe diameter | 25mm |
| Control Method | LCD + Remote Control |
| Noise | <75DB |
| Startup Current | 13A |
| Rated Current | 3A |
| Tank Capacity | 5L / 1.3gal |
| Fuel Consumption | 0.18-0.45 (L/H) |
| Item Weight | 8.9kg |
| Item Height | 39cm |
| Item Width | 17.7cm |
| Item Length | 40cm |

5. Installation
This section provides general installation guidelines. For a visual guide, please refer to the installation video below.
5.1 General Installation Steps
- **Unpacking**: Carefully remove all components from the packaging.
- **Measure Hole Spacing**: Use a measuring tape to determine the required hole spacing for mounting.
- **Drill Holes**: Use a 30mm tool to punch holes for the exhaust and intake pipes.
- **Install Exhaust Pipe**: Attach the exhaust pipe to the front of the unit using clips. Ensure the exhaust pipe is straight and not angled upwards to allow for smooth exhaust. The exhaust must be discharged outdoors.
- **Install Intake Pipe**: Attach the intake pipe to the back of the unit using clips.
- **Secure Machine**: Check that the machine is firmly installed and placed. Mark the location for mounting screws, drill pilot holes, and secure the unit.
- **Install Air Filter**: Install the air filter element onto the intake pipe. The clamp can be fixed in any position.
- **Install Silencer**: Attach the silencer to the exhaust pipe. Ensure no flammable materials are near the exhaust pipe. The exhaust pipe should not be bent too much to affect the exhaust.
- **Install Outlet Duct**: Attach the outlet duct to the air outlet.
- **Connect Power**: Connect the battery power cord. When installing the power supply, ensure that the power supply is 12V 15A or higher (for 12V models) or 24V 15A or higher (for 24V models).
- **Add Diesel**: Add diesel fuel to the tank.
- **Initial Startup**: Turn on the unit and wait for it to prime and start heating.
- **Ventilation**: Pay attention to ventilation when turning on the machine, especially in enclosed spaces.

6. Operation
6.1 Control Panel and Remote Control

6.1.1 S-A2013SL Model
Working Mode:
- **Gear Mode**: Gear setting adjustable from 1 to 10.
- **Temperature Control Mode**: Temperature adjustable from 8°C to 36°C. The control switch's gear position can be adjusted at any time. Adjusting the operating gear quickly reaches the set temperature, making the heater run more intelligently and economically.
- **Display**: When powered off, the screen shows current time. When powered on, it shows running time.
- **Fault Code**: If a fault occurs, a fault code will flash on the display for easier troubleshooting.
Instructions:
- **Power On/Off**: Press the [Power button] for 1 second to turn on/off.
- **Mode Switch**: In gear mode, press [Set button] to switch to temperature control mode. In temperature control mode, press [Set button] to switch to gear mode.
- **Gear Adjustment**: Press [Up Adjustment button] for +1 (max 10 gears/36°C), press [Down Adjustment button] for -1 (min 1 gear/8°C).
6.1.2 S-A2018 Model
Button Description:
| Symbol | Definition | Description |
|---|---|---|
| ⏻ | On/Off key | 1. Long press 1 second to start, screen displays ON. 2. Press and hold for 1 second to turn off the device, and the screen will display OFF. |
| OK | Confirm key | 1. Short press to check the machine status. 2. In the setting state, confirm the current setting value and enter the next parameter setting. |
| ⚙ | Setting Key | 1. Enter parameter setting mode. |
| ▲ | Up key | 1. In daily use (not in set state), increase the working temperature or oil volume. 2. In the setting state, adjust the setting parameters upward. |
| ▼ | Down key | 1. In daily use (not in set state), lower the operating temperature or oil volume. 2. In the setting state, adjust the setting parameters downward. |
6.2 Basic Operation Instructions
| Function | Operation | Display | Operation Notes |
|---|---|---|---|
| Query Machine state | Short press OK button | 1. Running time (24-hour system) 2. Ambient temperature 3. Work Temperature/Pump oil level 4. Supply voltage | Each press switches a state. Cycle display. |
| Manual/Automatic Mode Switching | Short press OK key and Up Adjust key at the same time | 1. Manual temperature control mode (P-Number HZ Representative Pump oil volume) 2. Automatic temperature control mode (25°C digital represents temperature Spend) | 1. In automatic mode, oil volume adjusts automatically to maintain set temperature. 2. Manual mode pump oil volume is limited; current setting won't auto increase/decrease oil volume and wind speed; clear gears. |
| Temperature measurement Unit Switching | Short press up and down keys at the same time | 1. Celsius display digital °C 2. Fahrenheit display number °F | Select temperature measurement unit according to usage habits. |
| On/Off Manual fuel Raise | Short press Set key and Adjust key at the same time | 1. Open: Initial display H-oF, short press up key to display H-on 2. Off: Initial display is H-on, short press down key to display H-OF 3. Short press setting key to exit and return to main interface | 1. Manual fuel filling function is disabled by default. 2. H-OF (closed state) H-on (open Enabled state). 3. When oil reaches machine's oil inlet, stop. Too much fuel causes black smoke. |
| Remote control pairing | Long press Down key | 1. HF-1 display (corresponding to simple remote control) 2. Then short press the power button on the remote control at the same time, Transmit remote control signal | 1. Remote control pairing function needs to be turned off when heater is turned off. Machine status. 2. If pairing is successful, device automatically exits pairing interface, enters power-on state. If pairing fails, it won't enter machine status. 3. If no remote control signal is received within time limit, device automatically exits pairing mode. |
6.3 Advanced Settings
Basic settings: In the power on state, press and hold the [Setting button] for 3s to enter.
- **Set Current Time**: Press [Set Key] to set, use [Up/Down Adjust Key] to switch.
- **Set Automatic Start Time**: Same method as above.
- **Set Running Time after Automatic Start**: Same method as above, switching unit is 0.5 hours.
- **Set Automatic Start Function ON/OFF**: Screen alarm icon is always on when enabled. Modify with [Up/Down Adjust Key], confirm with [Set Key]. Hold [Set Key] for 3s to save and return.
Engineering mode: Press and hold the [Up Adjust Key] and [Down Adjust Key] for 3s in the power-on state to enter engineering mode. Use [Up Adjust Key] for item +1, [Down Adjust Key] for item -1. Display shows data items:
- 001: Heater mainboard version number
- 002: fault code
- 003: Shell temperature
- 004: power supply voltage
- 005: Heater operating position
- 006: Cab temperature
- 007: altitude
- 008: Language switching
Temperature switching: Long press the adjustment key in the power-on state to switch between Fahrenheit and Celsius.
Remote control matching: Long press the upper adjustment key in the power-on state, interface displays "P-01". Then press the remote control plus and minus key, minus key, mode switch key, power button, and return to the operation interface after successful matching.
Pumping oil mode: Long press the [Confirm/Pump Oil] key when the version number is displayed during the first power-on self-test until the screen displays a countdown of '300s'. Release the key to start pumping oil. Pumping oil automatically ends after 300s or press the [Power Button] to end pumping oil and shut down.
Setting parameters: Short press the setting button three times. Enter password Code 1688. It is not recommended for customers to modify it at will. The default optimal parameters have been set.
7. Maintenance
- Regularly check the air filter for cleanliness and replace if necessary.
- Inspect all pipes (exhaust, intake, air outlet) for any blockages, damage, or loose connections.
- Ensure the fuel tank is adequately filled with clean diesel.
- Periodically check electrical connections for tightness and signs of wear.
- Keep the heater unit clean and free from dust and debris.
8. Troubleshooting (E-Codes)
If the heater encounters an issue, an error code (E-code) may be displayed. Refer to the table below for common fault codes and their solutions.
| Fault Light | Fault Type | Troubleshooting |
|---|---|---|
| E-01 | Abnormal voltage | Check if heater power supply voltage type matches actual vehicle voltage. For 24V, check if supply voltage is >32V or <18V. For 12V, check if supply voltage is >18V or <9V. Check if main wiring harness connector is loose. |
| E-03 | Ignition plug abnormality | Check if ignition plug is loosely connected. If faulty, replace it. If mainboard is faulty, replace it. |
| E-04 | Oil pump abnormality | Check if oil pump plug is loose or wiring harness is broken. If oil pump is faulty, replace it. |
| E-05 | Overheat protection | Furnace temperature sensor is wrong model or faulty, replace sensor. If mainboard is faulty, replace it. |
| E-06 | Fan abnormality | Check if fan impeller is stuck or fan plug is loose. If fan is faulty, replace it. Check if fan wheel induction magnet is missing or has wrong polarity. Check if mainboard wind speed sensor is normal. If mainboard is faulty, replace it. |
| E-08 | Lack of oil and flameout | Check if fuel tank is low on fuel. |
| E-09 | Overheat protection sensor | Check if temperature sensor connector is loose. If sensor is faulty, replace mainboard. If mainboard is faulty, replace mainboard. |
| E-10 | Secondary startup failure | Check if oil pump is working. Check if interfaces of oil circuit are waxed or blocked. |
9. User Tips
- **Heating Capacity**: While advertised as 8KW, some users note the actual heating capacity might be slightly lower but still sufficient for heating spaces like garages or small utility rooms.
- **Fuel Consumption**: At maximum setting, expect approximately 0.5 liters of diesel per hour.
- **Ventilation**: Always ensure adequate ventilation, especially when using the heater in enclosed spaces like garages or RVs.
- **Installation**: Pay close attention to the exhaust pipe installation to ensure it's straight and properly vented outdoors to prevent issues like black smoke.
- **Power Supply**: Verify your power supply meets the minimum requirements (12V 15A or 24V 15A) for stable operation.
- **Controls**: The controls are generally straightforward, but take a moment to familiarize yourself with the panel and remote programming.
- **Timer Reset**: If disconnecting from the network, the time and programming may need to be reset.
- **Manual**: The included manual might be basic; refer to the online PDF for more details if available.
10. Warranty and Support
Sunster is committed to providing quality products and support. All products are certified by CE, WEE, FCC, EAC, and UKCA.
For any problems or inquiries, please contact the store customer service or send an email to our after-sales team at: cs@sunster.tech.
For business-related issues, please contact: sunster@sunster.tech.