1. Introduction
This manual provides essential information for the safe and efficient operation of your Sunster 8KW All-in-One Diesel Air Heater. Please read it thoroughly before installation and use, and keep it for future reference.
1.1 Product Function
The Sunster Diesel Air Heater is designed to provide efficient heating for various vehicles and spaces. Its primary functions include:
- Eliminating damage to vehicles caused by sudden temperature drops.
- Improving the internal temperature of the vehicle cabin.
- Preheating engine coolant to prevent wear at low temperatures.
- Facilitating thawing of vehicle interiors, easier engine starts, and defrosting of car glass.
1.2 What's in the Box
Your package should contain the following items:

Image: Sunster Diesel Air Heater with all accessories laid out, including the main unit, remote control, air filter, fixed plate, air outlet pipe, intake pipe, exhaust pipe, manual, battery power cord, fixture accessories set, AC-DC adapter, and silencer.
- Main Heater Unit
- Remote Control
- LCD Switch Panel
- Air Filter
- Fixed Plate
- Air Outlet Pipe (stretchable)
- Intake Pipe
- Exhaust Pipe
- Battery Power Cord
- Fixture Accessories Set (clamps, screws)
- AC-DC Power Adapter
- Silencer
- User Manual (this document)
2. Product Overview
2.1 Internal Structure
Understanding the internal components helps in troubleshooting and maintenance.

Image: Exploded diagram showing the internal components of the heater, including the control box, air inlet, air fan, flame retardant impeller, ignition plug, combustion chamber, heating zone, air outlet, and safety plug.
- Control Box: Manages heater operations.
- Air Inlet: Where ambient air enters the unit.
- Air Fan & Flame Retardant Impeller: Circulates air.
- Ignition Plug: Initiates combustion of fuel.
- Combustion Chamber: Where diesel fuel is burned.
- Heating Zone: Transfers heat to the circulating air.
- Air Outlet: Where heated air exits the unit.
- Safety Plug: A safety component.
2.2 Heater Types
Sunster offers various configurations to suit different installation needs.

Image: Displays three different heater types: 1. Horizontal All-in-One Heater, 2. Vertical All-in-One Heater, and 3. Split Heater.
- Horizontal All-in-One Heater: Compact unit with all components integrated horizontally.
- Vertical All-in-One Heater: Compact unit with all components integrated vertically.
- Split Heater: Components are separated for more flexible installation.
3. Setup and Installation
Proper installation is crucial for the safe and efficient operation of your heater. If you are unsure about any steps, consult a qualified professional.
3.1 Placement Considerations
- Ensure the heater is placed on a stable, non-combustible surface.
- Maintain adequate clearance around the heater for proper airflow and heat dissipation.
- The unit can be installed in various environments such as RV compartments, truck cabins, vans, trailers, campers, or garages.
- Ensure exhaust gases are safely vented outside and away from any air intakes.
3.2 Power Connection
Your Sunster heater is adaptable to various voltage environments.

Image: Shows the heater connected to a standard AC 110-240V outlet and also highlights its compatibility with DC 12V/24V vehicle batteries, suitable for backup power.
- DC 12V/24V: Connect the provided battery power cord to your vehicle's 12V or 24V battery. Ensure correct polarity (red to positive, black to negative).
- AC 110-240V: Use the provided AC-DC power adapter to connect the heater to a standard AC outlet (EU/UK/US standard outlets are compatible).
- Ensure all connections are secure to prevent power interruptions or electrical hazards.
3.3 Air Pipe Connections
Connect the intake, exhaust, and air outlet pipes as follows:
- Intake Pipe: Connect to the air intake port. This draws in fresh air for combustion.
- Exhaust Pipe: Connect to the exhaust port. This vents combustion gases safely outside. Ensure it is routed away from living spaces and air intakes.
- Air Outlet Pipe: Connect to the heated air outlet port. This directs the warm air into the desired space.
- Secure all pipes with the provided clamps to prevent leaks.
3.4 Fuel Filling
- Ensure the heater is turned off and cool before filling the fuel tank.
- Use only clean diesel fuel.
- Open the fuel tank cap and carefully pour diesel fuel into the tank. Do not overfill.
- Securely close the fuel tank cap after filling.
3.5 Installation Video Guide
Video: A demonstration of the Sunster Diesel Air Heater, showing its features, internal workings, and various installation scenarios in vehicles and garages.
4. Operating Instructions
Your heater can be controlled via the integrated LCD switch panel or the remote control.

Image: Highlights the intelligent LCD panel and remote control. Features include a 24-hour timing function, energy conservation, color LCD screen, temperature/gear regulation, and language switching (German, English, Russian).
4.1 LCD Switch Panel (Model S-A2013SL)
4.1.1 Working Modes
- Gear Mode: Adjust heating power from 1 to 10.
- Temperature Control Mode: Set desired temperature from 8°C to 36°C. The heater intelligently adjusts operation to maintain the set temperature, optimizing fuel economy.
- Display: When powered off, the screen shows the current time. When powered on, it displays running time.
- Fault Codes: In case of a fault, a code will flash on the display for easier diagnosis.
4.1.2 Basic Operations
- Power On/Off: Press the [Power button] to turn the unit on or off.
- Mode Switch: Press the [Set button] to toggle between Gear Mode and Temperature Control Mode.
- Gear/Temperature Adjustment: Use the [Up Adjustment button] to increase gear/temperature (+1) up to 10 gears/36°C. Use the [Down Adjustment button] to decrease gear/temperature (-1) down to 1 gear/8°C.
4.1.3 Advanced Settings
To Enter Basic Settings: Press and hold the [Setting button] for 3 seconds while powered on.
- Set Current Time: Use [Set Key] to select, [Up/Down Adjust Key] to change.
- Set Automatic Start Time: Same method as setting current time.
- Set Running Time After Auto Start: Same method, unit is 0.5 hours.
- Set Auto Start Function ON/OFF: Alarm icon stays on when auto start is active.
Use [Up/Down Adjust Key] to modify, [Set Key] to confirm. Hold [Set Key] for 3s to save all settings and exit.
To Enter Engineering Mode: Press and hold both [Up Adjustment Key] and [Down Adjustment Key] for 3 seconds while powered on. Use [Up/Down Adjust Key] to navigate data items:
- 001: Heater mainboard version number
- 002: Fault code
- 003: Shell temperature
- 004: Power supply voltage
- 005: Heater operating position
- 006: Cab temperature
- 007: Altitude
- 008: Language switching
Temperature Switching (Fahrenheit/Celsius): Long press any adjustment key while powered on to switch temperature display units.
Remote Control Matching: Long press the [Up Adjustment Key] while powered on until