CERTEON Three Way Ball Valve

Contents

CERTEON Three-Way Ball Valve User Manual

Model: T/L Type Brass Three-Way Ball Valve

Brand: CERTEON

1. Introduction

This manual provides essential information for the safe and effective installation, operation, and maintenance of your CERTEON Brass Three-Way Ball Valve. This product is a brass three-way ball valve designed for fluid control in pipeline systems. It is available in T-type and L-type configurations to enable different flow diversion or shut-off functions. The valve is suitable for water, air, oil, and combustible gases in residential, commercial, and light industrial applications. The solid brass construction ensures durability, corrosion resistance, and reliable sealing performance.

For a comprehensive guide, please refer to the official user manual PDF: View User Manual (PDF)

2. Safety Information and Precautions

General Precautions

  • This valve is designed for manual operation only. Do not use tools to extend the handle for additional leverage.
  • Ensure the working pressure does not exceed PN16.
  • Confirm compatibility of the valve material with the working medium before installation.
  • Do not use the valve in systems exceeding the recommended temperature range.
  • Avoid sudden pressure surges that may damage internal sealing components.

WARNING! EU Market Reference

This product may be used in gas systems. Improper installation may result in gas leakage, fire, or explosion. Installation must be carried out by qualified professionals in accordance with applicable EU and national standards.

  • Do not exceed the rated pressure PN16.
  • Before maintenance, ensure the pipeline system is fully depressurized.
  • Keep out of reach of children.
  • Proper disposal: Follow WEEE directives and local regulations for metal and mechanical component recycling where applicable.

Note: The above warning information is for reference only. Final warning language must comply with the official language requirements of the destination EU country.

3. Specifications

Overview of T/L type brass ball valves with size options

Figure 1: CERTEON Three-Way Ball Valve Overview (T/L Type, various sizes)

Feature Detail
Product Type Three-Way Ball Valve
Valve Type T-type, L-type
Size Options (Female Thread) 1/4 inch (DN8), 3/8 inch (DN10), 1/2 inch (DN15), 3/4 inch (DN20), 1 inch (DN25)
Body Material Brass
Ball Core Material Brass
Stem Material Copper
Handle Material Zinc Alloy with Silicone Coating
Nominal Pressure PN16
Motivity Type Manual Operation
Handle Rotation Angle T-type: 180 degrees; L-type: 90 degrees
Applicable Media Water, Air, Oil, Coal Gas, Liquefied Petroleum Gas, Natural Gas
High-concerned chemical None
Origin Mainland China
Detailed dimensions for a T-type 1/4 inch (DN8) valve

Figure 2: T-Type 1/4" (DN8) Valve Dimensions and Features

4. Setup and Installation

Preparation

  1. Ensure the selected valve type (T or L) matches the intended flow control design of the pipeline.
  2. Confirm that the thread size corresponds to the pipe specification.
  3. Shut off upstream pressure before installation.
  4. Apply appropriate thread sealing tape or sealant to the male pipe threads.

Installation

  1. Install the valve using appropriate tools.
  2. Avoid excessive torque to prevent thread damage.

5. Operation

Handle Rotation and Flow Control

Comparison of T-Type and L-Type valves, highlighting brass body, pressure resistance, and brass ball core

Figure 3: T-Type and L-Type Three-Way Ball Valves

  • For T-type valves: Rotate the handle up to 180 degrees to control flow distribution.
  • For L-type valves: Rotate the handle 90 degrees to switch flow direction.
  • Ensure the handle is fully positioned at the desired stop point.

Data Reading (Flow Path Indication)

The handle direction indicates the internal ball port orientation. Align the handle with the desired flow path. Verify flow condition by checking downstream output.

L-type valve working principle with 90 degree handle rotation

Figure 4: L-Type Valve Working Principle (90° Rotation)

  • AB connected, BC not connected
  • BC connected, AB not connected
  • AC not connected
T-type valve working principle with 180 degree handle rotation

Figure 5: T-Type Valve Working Principle (180° Rotation)

  • When the handle points to A, AB is connected
  • When pointing to B, ABC is connected
  • When pointing to C, BC is connected

6. Storage and Maintenance

Storage

  • Store the valve in a dry, ventilated environment away from corrosive substances.
  • Keep protective caps on threads before installation to prevent contamination.

Maintenance

  • Periodically inspect for leakage, corrosion, or handle looseness.
  • If leakage occurs, depressurize the system before inspection or replacement.
  • Clean the external surface with a dry or slightly damp cloth. Do not use aggressive chemical cleaners.

7. Troubleshooting

This section provides guidance for common issues you might encounter with your three-way ball valve.

Problem Possible Cause Solution
Leakage from threads Improper thread sealant, damaged threads, insufficient tightening. Depressurize system. Reapply thread sealant (tape or compound) and re-tighten. Inspect threads for damage.
Valve not fully closing/opening Debris in valve, damaged ball/seat, handle misalignment. Depressurize system. Inspect for obstructions. Check handle alignment with flow path indicators.
Stiff handle operation Lack of lubrication, internal corrosion, excessive pressure. Ensure operating pressure is within PN16. Inspect for corrosion. (Note: Ball valves are generally maintenance-free for lubrication).

8. User Tips

  • Verify Valve Type: Always double-check that you have received the correct T-type or L-type valve before installation to ensure it matches your intended flow configuration.
  • Thread Sealing: For a leak-free connection, generously apply high-quality PTFE thread seal tape or pipe sealant to the male threads before assembly.
  • Avoid Overtightening: While a secure connection is important, overtightening can damage threads or the valve body. Use appropriate tools and apply firm but not excessive torque.

9. Support and Contact

If you encounter any issues not covered in this manual or require further assistance, please contact CERTEON customer support.

Contact Information:

  • Email: celiachen008@gmail.com
  • WhatsApp: +86 19542723588
General view of the T-type brass ball valve

Figure 6: CERTEON Three-Way Ball Valve

10. Compliance Disclaimer

This document is provided for product instruction purposes only. It does not constitute legal advice. The seller is responsible for ensuring compliance with destination market regulations.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.