QT-10HS H2S Gas Sensor Transmitter User Manual

Hydrogen Sulfide (H2S) Gas Sensor / Detector - Wall-Mounted Industrial H2S Odor Monitoring Device

1. Introduction

The SONGGER QT-10HS is a wall-mounted hydrogen sulfide (H2S) gas sensor designed for continuous monitoring of H2S concentration in industrial and environmental applications. It utilizes an electrochemical sensing principle and supports multiple output signals (RS485, 4-20mA, 0-5V, 0-10V) for easy integration with PLCs, control systems, and data acquisition equipment. This device provides stable and accurate measurements, making it suitable for long-term operation in harsh industrial environments.

QT-10HS H2S Gas Sensor Transmitter

Figure 1: QT-10HS H2S Gas Sensor Transmitter with key specifications.

2. Safety Information

WARNING!

  • Hydrogen sulfide is a toxic gas, and exposure to high concentrations may cause serious injury or death.
  • Installation, wiring, and maintenance must be performed by trained personnel.
  • Always disconnect the power supply before servicing the device.
  • Do not use the product in explosive atmospheres unless an explosion-proof version is specified.
  • Keep the product out of reach of children.
  • Disposal of the device must follow the WEEE Directive for electronic waste.
  • Ensure correct polarity when connecting the power supply.
  • Any installation, calibration, or maintenance work should be carried out by qualified personnel.

Note: The above warning information is for reference only. Final warning language must comply with the official language requirements of the destination EU country.

3. Product Overview

The QT-10HS sensor is designed for robust performance in various environments. Key features include:

  • Accurate and Reliable Measurements: Equipped with factory-calibrated sensors for high-precision detection and stable output.
  • IP65 Protection Rating: Waterproof, dustproof, and moisture-resistant, suitable for demanding indoor and outdoor applications.
  • Free Cloud Platform: Data can be uploaded to a cloud platform for real-time monitoring via mobile or computer.
  • Supports Secondary Development: Provides communication protocol for uploading data to custom platforms or software.
  • Durable Design: High-density waterproof housing with anti-aging, anti-oil, and interference-resistant cables.
  • Flexible Communication: Standard ModBus-RTU protocol with adjustable communication address and baud rate, maximum range up to 2000 meters.
Product Features and Benefits

Figure 2: Key features of the QT-10HS H2S Sensor.

Product Details

Figure 3: Detailed view of product components including high-density housing, waterproof membrane, and shielded cable.

4. Specifications

General Specifications

Parameter485 ModelAnalog Output Model
Power Supply10~30VDC10~30VDC
Output SignalRS485 (Modbus-RTU)4-20mA, 0-5V, 0-10V
Power Consumption0.12W0.25W
Operating Temperature-20℃~+50℃-20℃~+50℃
Operating Humidity15-90%RH (non-condensing)15-90%RH (non-condensing)
Pressure Range90-110Kpa90-110Kpa
Stability≤2% signal value/month≤2% signal value/month
Preheating Time≥5 minutes≥5 minutes
Service Life≥24 months≥24 months
Housing ProtectionIP65
Probe TypeBuilt-in probe or external probe (default 80cm, customizable up to 10m)

H2S Sensor Specifics

ParameterValue
Sensor TypeElectrochemical H2S sensor
Measurement Range0-100 ppm
Resolution1 ppm
Accuracy±2 ppm or ±10% of reading
Repeatability≤2%
Response Time≤35 s
H2S Zero Drift±5 ppm

Dimensions

The sensor unit measures 110mm (Length) x 85mm (Width) x 44mm (Height).

Sensor Dimensions Diagram

Figure 4: Sensor dimensions diagram.

5. Setup

5.1. Preparation

  • Before installation, confirm that the power supply voltage is within the specified 10-30 V DC range.
  • Verify the required output type (RS485, 4-20mA, 0-5V, 0-10V) before wiring.
  • Select a mounting location with good air circulation around the probe.

5.2. Installation

Mount the device securely on a wall or other suitable surface using the supplied accessories. Follow these steps for wall-mounted installation:

  1. Drill holes (5mm diameter) at the desired mounting points.
  2. Insert expansion plugs into the drilled holes.
  3. Secure the device to the wall using appropriate screws.
Wall-Mounted Installation Guide

Figure 5: Wall-mounted installation steps.

5.3. Wiring Instructions

Connect the power supply according to the terminal markings on the device. Refer to the wiring diagram below:

  • Brown wire: Power positive (DC 10~30V)
  • Black wire: Power negative
  • Yellow wire: 485A
  • Blue wire: 485B

For RS485 models, connect the A and B terminals to the host controller and configure the device address and baud rate as required. For analog output models, connect the signal output to the corresponding input channel of the control system.

Wiring Diagram for RS485 Model

Figure 6: Wiring diagram for RS485 model.

5.4. System Connections

The sensor can be integrated into various systems:

  • Single Connection: Connect to PLC, microcontroller, or computer via appropriate converters (e.g., 485 to 232, 485 to IC, RS485 to USB).
  • Multiple Connections: This product supports the use of multiple sensors on a single RS485 bus. Theoretically, a single bus can connect up to 254 RS485 sensors. The other end can be connected to a PLC with an RS485 interface, a microcontroller via an RS485 interface chip, or to a computer using an RS485-to-USB converter.
Single Connection Diagram

Figure 7: Single sensor connection diagram.

System Architecture Diagram

Figure 8: System architecture diagram for multiple sensors.

6. Operation

  1. After powering on, allow the device to preheat for at least five minutes.
  2. Once stabilized, the sensor will continuously measure the hydrogen sulfide concentration in the surrounding air.

6.1. Data Reading

  • For RS485 models: Read measurement data using the Modbus-RTU protocol.
  • For analog output models: Convert the current or voltage signal to ppm according to the configured measurement range.
Cloud Platform Connectivity

Figure 9: Sensor connectivity to cloud platform for data monitoring.

7. Maintenance

  • When not in use, store the device in a clean and dry environment at normal ambient temperature.
  • Periodically inspect the probe and clean it if dust or oil contamination is present.
  • Recalibration is recommended according to application conditions and local safety requirements.

8. Troubleshooting

If you encounter issues with your QT-10HS sensor, consider the following:

  • No Power: Check power supply connections and ensure voltage is within 10-30V DC.
  • Incorrect Readings: Ensure the sensor has completed its 5-minute preheating time. Check for proper air circulation around the probe and ensure it's not exposed to strong airflow or gas concentrations beyond its specified range.
  • Communication Issues (RS485): Verify wiring (485A to 485A, 485B to 485B), device address, and baud rate settings match the host controller.
  • No Analog Output: Check wiring to the control system's input channel and ensure the correct output type is selected.
  • Sensor Malfunction: If issues persist after basic checks, contact technical support.

9. User Tips

  • For optimal performance, ensure the sensor is mounted in an area representative of the gas concentration you wish to measure, away from direct drafts or stagnant air pockets.
  • Regularly check the sensor's protective membrane for any blockages or damage, especially in dusty or humid environments.
  • When integrating with a new system, perform initial tests with known H2S concentrations (if safe and feasible) to confirm accuracy and proper data interpretation.

10. Frequently Asked Questions (FAQ)

  • Q: Can the sensor be used outdoors?
    A: Yes, the sensor's IP65 waterproof design and durable materials make it suitable for harsh outdoor environments.
  • Q: Is customization available?
    A: Yes, we offer extended cable lengths, external displays, and probe type customization to meet specific requirements. Please contact us for specific customization needs.
  • Q: How to set up communication parameters?
    A: Communication address and baud rate can be configured via standard Modbus-RTU commands.
  • Q: What are the default configurations?
    A: Default configuration includes wall-mounted, non-display type, built-in probe, 0-100 ppm range, RS485/4-20mA/0-5V/0-10V output, 10~30V DC power, and IP65 housing.

11. Warranty and Support

This product comes with a standard manufacturer's warranty. For warranty claims, technical support, or further inquiries, please contact your vendor or the manufacturer directly. Please have your product model and serial number ready when contacting support.