1. Safety Information
- The tester is intended for use in compliance with local electrical usage rules. Avoid use in places inapplicable for electrics, such as hospitals or gas stations.
- To prevent functional decline or failure, the product should not be sprinkled or damped.
- The exposed part of the tester should not be touched by dust and liquid.
- During transportation and use, avoid violent collision and vibration to prevent damage.
- Do not leave the tester unattended while charging. If the battery becomes severely hot, power off the tester immediately. Do not charge for over 8 hours.
- Do not use the tester in high humidity environments. If damp, power off immediately and disconnect all cables.
- The tester should not be used in environments with flammable gas.
- Do not disassemble the instrument. If disassembly is necessary, contact the technical department.
- The instrument should not be used under strong electromagnetic interference.
- Do not touch the tester with wet hands.
- Clean with a dry cloth. For stubborn dirt, use a soft cloth with water or neutral detergent, ensuring the cloth is sufficiently wrung out.
2. Product Overview
2.1 General Introduction
The 4-inch IPS touch screen IP camera monitor is designed for the maintenance and installation of IP cameras, analog cameras, TVI, CVI, and AHD cameras. It supports testing 4K H.264/H.265 cameras via mainstream. The 800x480 resolution allows it to display network HD cameras and analog cameras in high resolution. The unit supports various ONVIF PTZ and analog PTZ controls. The combination of a touch screen and key buttons makes the IP camera tester very user-friendly.
The tester also serves as a valuable tool for Ethernet network testing. Additional functions include providing 25.5W PoE power to your camera, PING and IP address searching, an LED flashlight, DC 12V 3A power output, and more. Its portability, user-friendly design, and extensive features make the IP tester an essential tool for all installers and technicians.
2.2 Packing List
The package includes the following items:
- 1x CCTV Camera Tester
- 1x Lithium Polymer Battery (7.4V DC 2400mAh)
- 1x Wire Tracker
- 1x Adaptor DC12V/1A
- 1x Power Cable
- 1x BNC to Alligator Clip
- 1x BNC Cable
- 1x RS485 Cable
- 1x Audio Cable
- 1x Screen Protector
- 1x Tool Bag
- 1x Wrist Wrap

2.3 Function Interface
The tester features various ports and controls for comprehensive functionality. Refer to the diagrams and table below for detailed descriptions.

Indicators:
- Charge Indicator: Lights red when charging, turns off when charging is complete.
- RS485 Data Transmission Indicator: Lights red when data is being transmitted.


| No. | Description |
|---|---|
| 3 | Video image signal input (BNC interface) / AHD, CVI and TVI input (BNC interface) |
| 4 | Power battery switch |
| 5 | Return/Close: Return or cancel while setting parameters of the menu, close or decrease the aperture |
| 6 | Confirm key (Long press it to capture screen interface) |
| 7 | Function switching key |
| 8 | Press more than 2 seconds to turn on or off the device, short press to turn on or off the menu display |
| 9 | RS485 Interface: RS485 communication for the PTZ |
| 10 | LED lamp |
| 11 | DC12V3A power output, for provisional DC power supply |
| 12 | PoE power supply output or LAN test port (Use to test PoE or non-PoE IP camera) |
| 13 | UTP cable port: UTP cable tester port / Cable tracer port |
| 14 | DC12V 1A charging interface |
| 15 | Audio input |
| 16 | Micro SD card moveable, supports up to 32GB |
3. Setup
3.1 Installing the Battery
The tester has a built-in lithium-ion polymer rechargeable battery. For safety during transportation, the battery cable inside the battery compartment may be disconnected. Prior to use, ensure the battery cables are properly connected.
Pressing the power key continuously will power the tester on or off.
Notice: Always use the original adapter and connected cable provided with the device.
When the battery icon is full or the charge indicator turns off automatically, charging is complete. If the charge indicator turns off, the battery is approximately 90% charged. Charging can be extended for about 1 hour, and charging within 12 hours will not damage the battery.
Notice: If the instrument works abnormally, press the power key for several seconds to restore default settings.
3.2 Instrument Connection
3.2.1 IP Camera Connection
Power an IP camera with an independent power supply, then connect the IP camera to the IPC tester's LAN port. If the link indicator of the tester's LAN port is green and the data indicator flickers, it means the IP camera and the IPC tester are communicating. If the indicators do not flicker, check if the IP camera is powered on or if the network cable is not functioning properly.

If the IP camera requires PoE power, connect the IP camera to the IP tester's LAN port. The tester will supply PoE Power for the IP camera. Click on the icon labeled POE to turn the PoE Power off or on.
3.2.2 Analog Camera Connection
1. Connect the camera's video output to the IP tester's VIDEO IN. The image will display on the tester after pushing the PTZ icon.
2. Connect the camera or the speed dome RS485 controller cable to the tester's RS485 interface (note positive and negative connection of the cable).

3.2.3 HD Coaxial Camera Connection
CVI, TVI, and AHD cameras are classified as HD coaxial cameras. The connection method is similar to analog cameras. Connect the camera's video output to the IP tester's "Video IN" interface. The image will display on the tester. Connect the camera or speed dome RS485 controller cable to the tester's RS485 interface.
4. Operation
4.1 OSD Menu
The On-Screen Display (OSD) menu provides access to various functions and settings.
- Power On/Off: Press the power key for 2 seconds to turn on or off.
- Sleep Mode: Short press the power key to enter sleep mode. Press again to wake.
- Reset: If the tester works abnormally and cannot be turned off, press the power key for several seconds to reset.
4.1.1 Lite Mode
Lite mode allows for easy access to corresponding applications. In Lite mode, click the finger icon in the lower right corner until it turns yellow. Long-press an icon to move it to other items. To move an icon into a folder, long-press the application icon without clicking the finger icon.
4.2 Drop-down Menu
Press and slide from the top right corner twice to open the shortcut menu. This menu includes POE power output, IP settings, HDMI IN, CVBS, TV OUT, LAN, and general settings.
- CVBS: Click to open the CVBS application.
- LAN: Displays network port or Wi-Fi connection real-time upload/download speeds and other network parameters.
- Settings: Enters the settings interface.
- IP: Enters the IP Settings interface.
- PoE Power Output: Turns the tester's PoE power application on or off.
4.3 Screen Capture
Long-press the "Enter" key to capture the screen interface at any time. Captured images are saved to "file management - sdcard - Pictures - Screenshots".
4.4 TesterPlay (Mobile Screen Projection)
This feature allows mobile screen projection (Android only). The tester creates a Wi-Fi hotspot. Connect your mobile phone to this hotspot, or ensure both the tester and phone are on the same Wi-Fi network. Download and install the Remote Control app on your mobile phone. Tap the icon, select "TesterPlay" app, and click "Start" to generate the RTSP URL.
For PC screen projection, install VLC player on your PC. Turn on VLC player's "Media - Open Network Streaming" and input the RTSP address from the tester's two-dimensional code. Click "Play" to view the real-time projection.
Video 1: Product Demonstration and Features
4.5 Rapid Video
Press the rapid video icon to activate this function. It detects all network cameras and automatically plays their images.
4.6 IP Discovery
Press the IP discovery icon to auto-scan the entire network segment's IP addresses. The tester can automatically modify its IP to match the scanned camera's IP. It auto-searches connected network segment IPs and adds IPs from different segments. It can detect unactivated Dahua and Hikvision cameras, prompting you to activate them.
4.7 Rapid ONVIF Test
Rapid ONVIF can display 4K H.265/H.264 camera images via the tester's mainstream. It allows one-key activation of cameras. The tester auto-scans all ONVIF cameras in different network segments, lists their names and IP addresses, and can auto-login and display camera images. Default login uses 'admin' password; if modified, use the new password.
ONVIF PTZ Control: Tap the image in the desired direction to move the PTZ camera. Compatible IP PTZ cameras will rotate accordingly. The PTZ rotation direction is displayed on the top left corner of the image.
IP Camera Video Settings: Click "Video Set" to enter the IP camera's encoder and resolution settings. Make changes and click "OK" to save.
Image Setting: Click "Imaging Set" to adjust image brightness, saturation, contrast, sharpness, and backlight compensation mode.
Profiles: Click "Profiles" to view current video streaming configuration files and switch between main and minor streams.
Preview Pictures: Quickly preview and zoom in/out pictures, with automatic and manual refresh options.
Identification: Click "Identification" to view camera information.
Time Set: Click "Time set" and select "Manual set" to configure the camera's time.
Maintenance: For camera software reset or to restore factory settings.
User Set: Modify camera user name, password, and other parameters.
Network Setting: Click "Network Set" to change the IP address. Note that some cameras may not support IP address changes after saving.
Image Display: If the network video input supports up to 1080p, the enlarged image will be very clear, aiding installers in ensuring IP camera video coverage and placement. Image can only be enlarged in SD mode.
Snapshot: Click the "Snapshot" icon to capture the current video frame as a JPEG file to the SD card. If manual storage is selected, a dialog box will appear to input a file name. If auto-storage is selected, the tester will automatically name and save the files.
Record: Click the "Record" icon to start video recording. A red recording icon will flash, and a timer will indicate elapsed time. Click "Record" again to stop and save the video file to the SD card.
Playback: Click the "Playback" icon to view recorded videos. Double-click a video to play it. Click to return to the last menu.
To rename or delete a photo/video, click and hold on the file until the option appears.
Lens Simulation: Simulate different lens display areas (2.8/3.6/4/6/8/12/16/25mm) to choose the suitable camera lens.
PTZ Control: Set preset positions by moving the camera, entering the preset number, and confirming. Call preset positions by selecting the number and clicking "Call".
4.8 Video Monitor Test (Analog Camera)
Click the icon to enter analog camera test mode. The image will display on the tester. Double-tap the screen for full-screen display.
PTZ Controller Parameter Setting: Select and click the "PTZ" icon to enter PTZ settings.
- Protocol: Use arrow keys to select the protocol. Supports over thirty PTZ protocols (e.g., Pelco-D, Samsung).
- Port: Select the communication port for PTZ camera control (RS485).
- Baud Rate: Select the baud rate matching the PTZ camera (e.g., 150/300/600/1200/2400/4800/9600/19200/57600/115200).
- Address: Set the ID according to the PTZ camera's ID (0~254).
- Pan Speed: Set the pan speed of the PTZ camera (0~63).
- Tilt Speed: Set the tilt speed of the PTZ camera (0~63).
- Set Preset Position: Set and save preset position numbers (1~128).
- Call Preset Position: Call a special preset number to access the dome camera menu.
To control PTZ by screen touch, tap left, right, upward, or downward on the touch screen. Use two fingers to zoom in and out.
Video and Storage Setting: Click the "Set" icon to configure analog video image brightness, contrast, color saturation, and file storage method (auto or manual). If manual, you can name files.
For analog video input, the 720x480 resolution may result in a less clear zoomed image. For network digital video input, supporting up to 960x540, the zoomed image remains clear, which is helpful for IP camera installation.
4.9 CVI Camera Test
For HD CVI camera and CVI dome camera testing and PTZ control, click the CVI icon. When an HD CVI signal is input, the tester will display the image resolution. Double-tap the screen for full-screen display. The tester supports resolutions including 1280x720P (25/30/50/60FPS), 1920x1080P (25/30/50/60FPS), 2560x1440P (25/30FPS), and 3840x2160 (12.5/15FPS).
Coaxial PTZ Control: Select "UTC" for coaxial control. Enter the PTZ address to set parameters.
Coaxial Camera Menu Settings: Tap the "UTC" icon, select "menu setting" to enter the dome camera menu. Input the calling dome camera menu address code. After setting parameters, press "Enter" or click the icon to call the dome camera menu.
4.10 TVI Camera Test
For HD TVI camera and TVI dome camera testing and PTZ control, click the TVI icon. When an HD TVI signal is input, the tester will display the image resolution. Double-tap the screen for full-screen display. The tester supports resolutions including 1280x720P (25/30/50/60FPS), 1920x1080P (25/30/50/60FPS), 2048x1536P (18/25/30FPS), 2560x1440P (15/25/30FPS), 2688x1520P (15FPS), 2592x1944P (12.5/20FPS), and 3840x2160P (12.5/15FPS).
Coaxial Camera Menu Settings: Similar to CVI camera test, tap the "UTC" icon, select "menu setting" to enter the dome camera menu. Input the calling dome camera menu address code. After setting parameters, press "Enter" or click the icon to call the dome camera menu.
4.11 AHD Camera Test
For AHD camera and AHD dome camera testing and PTZ control, click the AHD icon. When an AHD signal is input, the tester will display the image resolution. Double-tap the screen for full-screen display. The tester supports resolutions including 1280x720P (25/30FPS), 1920x1080P (25/30FPS), 2048x1536P (18/25/30FPS), 2560x1440P (15/25/30FPS), 2592x1944P (12.5/20FPS), and 3840x2160P (15FPS).
Coaxial PTZ Control: For UTC control, select "PTZ control" or "PTZ control-2" (AHD cameras may have different orders). If coaxial PTZ control is used for the AHD camera, no parameter settings are needed.
4.12 Network Tool
4.12.1 IP Address Scan
Connect the cable to the LAN port, click the IP address scan icon. Set your IP address search range by changing the Start and End IP addresses. Click "Start" to scan. You can also input an IP address in the Port Number Scan to scan for open ports.
4.12.2 PING Test
Connect a network cable to the LAN port and click the PING icon. Set your Local IP, Remote IP, Packet count, Packet Size, Packet time, and Timeout. Press "Start" to begin pinging. If the camera or network device is not configured correctly or not plugged in, it will show "Destination host unreachable" or 100% packet loss. If connected, it will show 0% packet loss.
PING testing is a conventional network debugging tool for checking if the connected IP camera or other network equipment's Ethernet port is working normally and if the IP address is correct. It's normal for the first data packet to be lost when the test starts.
4.12.3 Network Test (Ethernet Bandwidth Test)
To use the Network Tester, you will need two IP testers. One acts as a Server, and the other as a Client. Both devices must be on the same network segment to communicate. Click the icon to open the Network Tester app.
Start the Server: Click "Start Server" to use the tester as a Server. Its IP address will display at the top of the screen.
Start Send Packet Test: Using the other IP tester, type in the Server's IP address at the top right corner of the screen. This app sends packets for network speed testing. Click "Start" to send packets and begin testing.
Network bandwidth testing can also be performed with a computer using compatible network bandwidth testing software. Install the software on a computer to act as a test Client or Server for mutual testing with the tester.
4.12.4 Port Flashing
Connect a network cable to the meter's "LAN" port, click the icon to open the Port Flashing app. Click "Start". The IP tester sends a unique signal to make the connected LAN port of the switch flash. If the tester and PoE switch are connected correctly, the LAN port of the PoE switch will flash at a special frequency. If not, there are no changes on the LAN port.
This function helps installers easily and quickly find the connected Ethernet cable, preventing mistaken insertion or disconnection of non-corresponding cables.
4.12.5 DHCP Server
Click the DHCP icon to open the DHCP server app. Select the "Start" checkbox and make any desired changes to the network settings. Click "Save" to assign dynamic IP addresses for IP cameras and other networked devices. Click "Refresh" to check your Client list.
4.12.6 Trace Route
This function determines the path of IP packet access to a target. Note: Trace route testing results are for reference only. For accurate tracking, use a professional Ethernet tester. Click the Trace Route icon to enter. Input the tracking IP address or domain name in the Remote Host IP field. Set the maximum hop count (default is 30). Click "Start" to trace the goal address.
4.12.7 Link Monitor
Click the Link Monitor icon to open the app. This app checks if an IP address is occupied by other network devices, preventing new address conflicts. Click "Add" and enter the desired IP address. To test different network segments, go to IP Settings and make changes. Once desired IP addresses are added, click "Start". A checkmark indicates the IP address is occupied; an 'X' indicates it's available. Click "Stop" to end testing.
When adding an IP camera or other network device to the current network group, the new IP address must not be occupied to avoid IP conflicts and ensure normal equipment operation.
4.13 PoE Power / DC12V 3A Power Output
When the tester is turned on, the DC 12V power output functions are automatically enabled. To use the PoE Power Output function, click the icon and change the switch to "ON" or "OFF". The IP camera needs to be connected to the LAN port before turning PoE Power on. If the IP camera supports PoE, the power is delivered via pins 1, 2, 3, and 6 on the LAN port. The IP tester will display "48V ON" when PoE power is active.
Notice:
- Do not input power into the "DC12/3A OUTPUT" port.
- Ensure the cable connected to the tester's LAN port is a straight-line cable and has no short circuit, otherwise, it will damage the tester.
- Before using PoE power output, verify that the IP camera supports PoE power. Otherwise, it may damage the IP camera.
- The instrument's PoE maximum power output is 24W. If an ultra-high-power load occurs, the tester will enter protection mode.
- The IPC tester power output is close to 3A. If the IP camera's power exceeds 3A, the tester will automatically enter protection mode. Disconnect all connections and reboot the tester to resume use.
- Ensure the tester has sufficient charge; otherwise, it may not be able to provide enough output power.
4.14 RJ45 Cable TDR Test
Connect a cable to the tester's LAN port, click the icon to enter the RJ45 cable TDR test app.
Single Test: Tests cable status, length, and attenuation.
Repeat Test: Continues to test cable status, length, and attenuation.
Status: Displays "online" if linked up, "open circuit" if not linked or open, and "short circuit" if a cable pair is shorted.
Length: Maximum test length is 180 meters. Can test cable length for open or short circuits. If "online", the result will not be accurate.
Cable Quality Test: Green indicates good quality, yellow indicates poor quality, red indicates water-damaged cable. Attenuation value displays for cables over 10 meters.
Advanced Test: Tests cable pair status, length, attenuation, reflectivity, impedance, skew, and other parameters.
Attenuation Reflectivity: After link up, if reflectivity is 0, it indicates the best quality communication.
Impedance: After link up, if impedance is 100 Ω, it indicates the best quality communication. The range is generally 85-135 Ω.
Skew: After 1000M link up, if skew is 0ns, it indicates the best quality communication. If over 50ns, it will cause a Bit Error Rate in transmission.
4.15 Cable Test
Click the icon to enter. Test LAN cable or telephone cable. Connect the LAN or telephone cable to the CCTV tester and cable tester. The connecting status, cable type, wire sequence, and serial number of the cable tester kit will be displayed. The cable tester number is 255. Additional costs apply for several different number types.
Tap "cable test sketch map" to view straight-through and crossover cable sketches for line sequence reference.
4.16 Cable Tracer (*Optional)
Connect the tested cable or BNC cable to the UTP port or the CABLE SCAN (VIDEO OUT) port. Click the icon to enter, then click "Number" to adjust the audio type.
UTP Mode: Used for searching normal network cables or other cables.
STP Mode: Used for searching shielded network cables.
Rotate the switch of the cable tracer to turn it on. Clockwise rotation increases sensitivity, while anticlockwise rotation reduces sensitivity. The cable tracer and cable tester can be used simultaneously to accurately identify network cables. Connect the other end of the tested network cable to the "UTP" port of the cable tracer. The cable sequence, continuity, test box number, and network cable type will be displayed on the right side of the meter interface. 'G' indicates the continuity of the shielded network cable.
The 1-8 indicators of the cable tracer will flash according to the cable sequence. DIRECT / CROSS / OTHER indicators show the network cable type. Press the "MUTE" button for 2 seconds to enter silent mode (indicated by a "Di" sound). In silent mode, cable type can be judged by the indicator light. Press "MUTE" again to exit silent mode.
This feature is convenient for finding the other end of cables in messy security maintenance and network engineering setups. When searching BNC cable, connect one alligator clip to the copper core or net of the BNC cable, and the other to the earth wire.
Notice: The cable tracer battery must be connected according to the corresponding positive (+) and negative (-) poles, otherwise it will damage the tester.
Notice: When the cable tracer tester receives an audio signal from the tester, it may be influenced by other signals and produce some noise.
4.17 Audio Record
Connect an audio device to the IP tester's audio input port. Click the icon to enter the Audio Recorder app. Click the red button to stop, and the unit will prompt you to save the recording.
4.18 Data Monitor
Click the icon to enter. Click "Setting" to choose the baud rate of RS485/RS232; it must match the DVR or control keyboard. If the DVR or control keyboard sends code to the tester and it can be read, the protocol will be shown. If not, it will show "P:---". While the tester receives the code, press "Return" to clear. This function displays the PTZ control code from the multifunctional keyboard or DVR, allowing engineers to check RS485 transmission status and analyze the protocol.
4.19 Audio Player
Click the icon to enter. The audio player supports MP3 format audio files only.
4.20 Media Player
Click the icon to enter. The Media player can browse video and image files. It supports video formats such as MP4, H.264, MPEG4, and MKV. IP tester recorded files can be played directly via the Media player. The Media player will automatically display video files from the SD card. Click on the desired file to play. Click RETURN to exit.
To rename or delete an existing file, press the file name for a few seconds until the screen below appears. You can then rename or delete the file by pressing the desired option.
4.21 RTSP Player
The RTSP Player app allows you to view the RTSP video stream from an IP camera. If you were unable to view your camera via the ONVIF or IPC Test apps, it is possible your camera will have an RTSP stream and you can view live video. From the main menu, select the "APP Tool" folder and then select the "RTSP Player" to open the app. If the IP camera uses MJPEG, select the RTSP icon. If the IP camera uses H.264, select the "RTSP HD" icon.
Local IP: This is the IP tester's IP address.
RTSP Add: Manually enter the IP camera's RTSP URL or click "Search" to find network cameras using an RTSP stream.
IPC Username: Enter the IP camera's user name.
IPC Password: Enter the IP camera's password.
Once all necessary information is entered, select "Enter" to view the RTSP stream.
Note: If the IP tester does not auto-detect the RTSP stream, refer to the specific camera manufacturer for the RTSP stream URL. This can often be found online with a search for the camera model number and "RTSP".
4.22 Hik Test Tool
The Hik test tool app is designed for activating and debugging Hikvision cameras. It can auto-identify inactivated Hikvision cameras and display images from them.
Activation: Select "online detection" to display inactivated cameras and click "activate".
Auto Open ONVIF Protocol: After activation, new HIK cameras can click "play", "modify the channel name", "modify network information", or "modify user information" to auto-open the selected camera's ONVIF protocol.
Play: If the security status shows the camera is "activated", enter the correct camera password and click "play" to pop up "private protocol" or "speed ONVIF" options. Select the protocol needed to view camera images.
Modify Channel Name: Clicking "Modify the channel name" will open OSD settings, including time, channel name, and other options.
Modify Network Information: Supports "modify" and "batch modify" camera IP address, subnet mask, and other parameters. (Password required for camera web page login).
Modify User Information: Modify the camera's user name and password.
Factory Reset: Performs a camera factory reset. This will soft reset the camera, saving the device's user name, password, and network settings. Other settings are restored to factory defaults.
4.23 Dahua Test Tool
The Dahua test tool is developed for installing and debugging Dahua IP cameras. It can display images, and modify IP, user name, and password, making Dahua camera testing more convenient. It supports batch activation and network segment modification for Dahua cameras. Click the "DH" icon to enter.
Select the camera from the online detection menu. If the camera supports non-verification login, you can click "play" directly to view the image. If not, select "camera" from the online detection menu, input the correct user name and password, then click "log in".
Play: Displays IP camera live video (mainstream or secondary stream).
Modify Network Information: Modifies camera parameters such as IP address, subnet mask, and gateway. (Password required for camera web page login).
Modify User Information: Modifies camera user name and password (ONVIF, Dahua test tool, IPC TEST user name and password, not web user name and password).
Factory Reset: Performs a camera factory reset.
4.24 Update
Copy the downloaded update file to the SD card's "update" directory (create if it doesn't exist). Click the icon to open the Update menu. Select "Local Update" to update via the SD card or "Online Update" to check for updates via the internet. If applications need updating, they will be listed; click to update them.
Online Update: Connect to the internet to update apps.
System Update: Connect to the internet to update systems.
4.25 Office
Quick office app (supports Excel, Word, PPT formats) for editable documents.
4.26 LED Flashlight
Convenient for installation or maintenance in the evening or dark. Click the icon to enter. While in the flashlight app, click the red button to turn the LED lamp on/off. If you don't press the red button to shut off the lamp and exit the app, the lamp will remain on. Click the Time Setting button to set a timer for automatic shut-off.
4.27 Browser
Click the icon to enter. Type the camera's IP address and press "Go" to access the IP camera's interface.
NOTE: You will not be able to view live video in the web browser. For viewing video, use the IP tester's live camera view Apps.
The IP camera and IP tester must be on the same network segment for the browser to interface with the camera. If not, press "RETURN" to exit. Open the "Settings" app from the main menu to change the IP tester's network settings to match those of the IP camera.
4.28 Notepad
Notepad can be used to record important testing results. Click "Save" to save contents. Notepad automatically records the storage date and time. Click to view the notepad; all saved contents will display. Click each record bar to show details. Press and hold a record bar for several seconds to prompt deletion.
4.29 System Setting
Click the icon to enter.
Language & Input: Select your desired language (English, Chinese, Korean, Russian, Italian, Polish, Spanish, Japanese, Turkish, Deutsch, Serbian, Czech, Vietnamese, French). You can also select or install other typing methods.
Date/Time: Set the date/time of the IP tester.
IP Setting: Manually set the IP address, Subnet Mask, Default Gateway, and DNS address, or select "Dynamic allocation" to use DHCP. To test multiple network segments, click "Advanced" and then "Add" to enter another IP address.
WLAN Net: Turn Wi-Fi on/off. When Wi-Fi is on and connected, it will scan for wireless networks in your area.
Wi-Fi Hotspot: Input SSID name and password, then click "OK" to create a Wi-Fi hotspot.
Brightness: Set the desired brightness of the IP tester and adjust sleep time settings.
Volume: Set the volume level.
SD Card: Displays SD Card Capacity. You can format or unmount the SD card before removing it.
FTP Server: Once the IP tester connects to a network, a computer can read SD card files via FTP. Start the FTP server, then input the tester's FTP address in the PC's address bar to read, copy, and edit files from the SD card without an SD card reader.
Version Information: Shows application version information. Long-press any app icon for several seconds to uninstall.
Screen Display Rotation: Click "Screen Rotation" to flip the IP tester's display 180 degrees, convenient for connecting LAN cables without flipping the unit.
PTZ Address Scan: Toggle PTZ Address scan on/off before entering the "PTZ controller" app. This must be on to use the PTZ Scan feature.
Online Registration: Online update requires registration. After connecting to the network, fill in registration information.
User Feedback: Connect to the network to write feedback.
Lock Screen: Default is not locked. Choose password lock, pattern lock, or "NO".
Password Lock Screen: Set a password (digitals, letters, characters). Input it again to confirm. When in standby or turned on, input your password to enter. To modify, input the old password, then set a new one.
Pattern Lock Screen: Draw a pattern to lock. To modify, draw the old pattern, then a new one.
Restore Factory Settings: All personal files and apps will be removed.
4.30 File Explorer
Click "File" on the top bar tool to select internal or external storage. Click the top right corner icon "..." for a pop-up menu to select other operations or exit. It includes Music, Videos, Pictures, Documents, zip files, etc., for convenient viewing and management.
4.31 Theme
Desktop Style: Select Lite mode or normal mode.
Theme Colors: Includes fixed order and random order. Click "set" to save. Pressing a color icon for several seconds moves it to the rectangle area; pressing again deletes it.
Background Color: Select colors from the Color Phase or input RGB values. After setting, click "set" to apply as desktop or application background.
5. Maintenance
- Keep the device clean and free from dust and liquids. Use a soft, dry cloth for cleaning. For stubborn dirt, a slightly damp cloth with neutral detergent can be used.
- Avoid dropping or subjecting the tester to strong impacts.
- Store the device in a cool, dry place away from direct sunlight and extreme temperatures.
- When not in use for extended periods, ensure the battery is partially charged (around 50%) to prolong its lifespan.
- Do not attempt to repair the device yourself. Refer to qualified technicians for any issues.
6. Troubleshooting
- Tester not powering on: Ensure the battery cable is properly connected inside the battery compartment. Check if the battery is charged.
- Battery severely hot during charging: Immediately power off the tester and disconnect from the power source. Do not charge for over 8 hours.
- Instrument works abnormally: Press the power key for several seconds to restore default settings.
- IP camera not communicating: Check if the IP camera is powered on. Verify the network cable connection to the tester's LAN port. Ensure the link indicator is green and the data indicator flickers.
- PoE power output not working: Ensure the IP camera supports PoE. Check if the tester has sufficient charge (more than 80%). Disconnect all connections and reboot the tester if it entered protection mode due to high power draw.
- Network test (PING) shows 100% packet loss: The IP camera or network device may not be configured properly or is not plugged in.
- RTSP stream not detected: Refer to the camera manufacturer's documentation for the specific RTSP stream URL and manually enter it.
- Browser cannot view live video: This is normal. Use the IP tester's dedicated live camera view apps for video.
- Browser cannot interface with camera: Ensure the IP camera and IP tester are on the same network segment. Adjust IP tester network settings via the "Settings" app if needed.
- Cable TDR test inaccurate: If the cable status is "online", the length test result may not be accurate.
- Cable tracer noise: The cable tracer may pick up other signals and produce noise.
7. Specifications
| Feature | Description |
|---|---|
| Model | IP Camera Tester |
| Display | New 4-inch IPS touch screen CCTV tester 800x480 resolution |
| Network port | 10/100/1000M auto adjust, RJ45 |
| WIFI | Built-in WIFI, speeds 150M, display wireless camera image |
| H.265 Main stream test | New hardware decoding, 4K H.265/H.264 camera image display by mainstream testing |
| IP discovery | Auto-scan the whole network segment camera IP |
| Rapid ONVIF | Search camera quickly, auto log in and display image from the camera, activate Hikvision camera |
| Hik test tool | Activate Hikvision camera, display image from the camera, modify IP, user name and password parameters etc. |
| DH test tool | Activate Dahua camera, modify IP, user name and password parameters etc. |
| IP camera type | ONVIF, ONVIF PTZ, Dahua IPC-HFW2100P, Hikvision DS-2CD864-E13, Samsung SNZ-5200, Tiandy TD-NC9200S2, Kodak IPC120L, Honeywell HICC-2300T, RTSP Viewer |
| CVI video signal test | 1 channel CVI input (BNC interface, resolution support 720p 25,30,50,60fps/ 1080p 25,30fps/2560x1440p 25fps,30fps, 3840 x 2160 12.5/15 FPS |
| TVI video signal test | 1 channel TVI input (BNC interface), resolution support 720p 25,30,50,60fps/1080p 25,30fps/2048x1536p 18,25,30fps, 2560x1440p 15,25,30fps/2688x1520p 15fps, 2592x1944p 12.5,20fps/3840 x 2160 12.5/15 FPS |
| AHD video signal test | 1 channel AHD input (BNC interface), resolution support 720p 25,30fps / 1080p 25,30fps/2048x1536p 18,25,30fps, 2560x1440p 15,25,30fps/ 2592x1944p 12.5,20fps, 3840 x 2160 15 FPS UTC control and call OSD menu |
| Analog video test | 1 channel BNC Input, NTSC/PAL (Auto adapt) |
| Snapshot, Video record and playback | Capture current images and record live video as JPG file. Media player will view photos and playback video |
| TesterPlay | Screen projection: tester, mobile phone and PC display at the same time (For android version mobile phone) |
| 12V/3A power output | Output DC12V/3A power to camera |
| PoE power output | 48V PoE power output, Max power 25.5W |
| Theme | Self-define icons, desktop and application interface background, modify interface sliding effect |
| Drop-down menu | Includes PoE power switch, IP setting, CVBS, etc. |
| Audio test | 1 channel audio signal input |
| RJ45 cable TDR test | RJ45 cable TDR test and cable quality test, to test cable pair status, length, attenuation reflectivity, impedance, skew and other parameter. |
| UTP Cable tester | Test UTP cable connection status and display on the screen. Read the number on the screen |
| Cable tracer* (Optional) | Using the advanced multiplexing technique, the cable tracer and cable test in the same interface. Find a connected cable from a bundle of cables using audio tones |
| PTZ control | Support RS485 control, Baud 600-115200bps, Compatible with more than 30 protocols such as PELCO-D/P, Samsung, Panasonic, Lilin, Yaan, etc. |
| Data monitor | Captures and analyzes the command data from controlling device, also can send hexadecimal |
| Network test | IP address scan, link scan, and Ping test. Quickly search for the IP camera's IP address on your network |
| External power supply | DC 12V 1A |
| Battery | Built-in 7.4V Lithium polymer battery, 2400mAh |
| Rechargeable | After charging 4~5 hours, normal working time 8 hours |
| Operation setting | OSD menu, select your desired language: English, Portuguese, Korean, Russian, Italian, French, Polish, Spanish, Japanese, Turkish, Deutsch, Serbian, Czech, Vietnamese etc. |
| Auto off | 1-30 (mins) |
| Working Temperature | -10°C ~ +50°C |
| Working Humidity | 30%-90% |
| Dimension/Weight | 126mm x 83mm x 33mm / 0.32kg |
The data above is for reference only; any changes will not be informed in advance. For more detailed technical inquiries, please contact our Technical Department.
8. User Tips
- Always ensure the battery is adequately charged before starting a job to avoid interruptions, especially when using PoE output.
- Familiarize yourself with the OSD menu and shortcut menu for quicker access to frequently used functions.
- When testing IP cameras, if direct connection fails, try using the RTSP Player with the camera's specific RTSP URL.
- Utilize the Port Flashing feature to quickly identify cables in complex installations.
- Regularly check for software updates to ensure optimal performance and compatibility with new camera models.
9. Warranty and Support
Keep the S/N label for after-sale service within the warranty period. Products without an S/N label will be charged for repair service.
If you have any questions or problems while using the IP camera tester, or if damages occur to the product, please contact our technical Department for assistance.