YIDI SV-PL

Rate this product if you’ve used it
Contents

YIDI Pneumatic Check One Way Valve Quick Push-in Connector Kit

Instruction Manual

Product Overview

The YIDI SV-PL series pneumatic check one-way valve quick push-in connector kit is designed for efficient and reliable control of air flow in pneumatic systems. These fittings allow air to flow in one direction while preventing backflow, ensuring system integrity and performance. They feature a quick push-in design for easy and secure tube connections.

YIDI Pneumatic Check Valve
Figure 1: YIDI Pneumatic Check One Way Valve

The valves are available in various sizes to accommodate different hose outer diameters (O.D.) and male thread connections, making them versatile for a wide range of applications.

Assortment of YIDI Pneumatic Check Valves and Fittings
Figure 2: Assortment of YIDI Pneumatic Check Valves and Fittings

Key features include:

  • One-Touch Push-in Quick Connection
  • Elbow Check Valve Design
  • Durable construction with Nitrile Rubber, Plastic & Metal
  • Suitable for Clean Air, Vacuum, and non-toxic gases
  • Compatible with Soft Nylon (PA) and Polyurethane (PU) tubes

Safety Instructions

  • Pressure: Ensure zero pressure in the tubing before removal or installation.
  • Spatter Zones: Avoid using standard fittings in spatter-producing areas.
  • Monitor Conditions: Stay within specified pressure and temperature ranges (refer to specifications).
  • Environment: Avoid corrosive gases, chemicals, and extreme conditions.
  • Placement: Avoid areas with heavy vibrations or shocks.
  • Direction: Install tubing in the correct one-way direction as indicated by the valve markings.
Check Valve Flow Diagram
Figure 3: Check Valve Symbol and Flow Direction (A to B allowed, B to A blocked)
Visual representation of one-way flow
Figure 4: Visual Flow Direction (Green check for allowed flow, Red cross for blocked flow)

Setup and Installation

Preparation:

  1. Cleaning: Clean the piping thoroughly before connection to remove any debris or contaminants.
  2. Tubing Cut: Ensure the tubing is cut perpendicularly. Avoid any scratches or damage to the tubing's outer diameter, as this can compromise the seal.
  3. Pipe Length: Select a proper pipe length to avoid excessive bending, which can stress the fitting and tubing.
Incorrect tube cutting example
Figure 5: Example of incorrect tube cutting (indicated by 'X')

Connecting the Tubing:

  1. Grasp the tubing firmly.
  2. Slowly push the tubing into the fitting until it comes to a complete stop. You should feel it lock into place by the internal spring gasket.
  3. Connection Check: After connecting, gently pull the tubing to ensure it is securely seated and to check for a proper seal.

Removing the Tubing:

  1. Push evenly on the release button flange of the fitting.
  2. While holding the release button, pull the tubing out to withdraw it.
  3. Removal Caution: Avoid rotating the tubing fully during removal to prevent damage to the fitting or tubing.
Installation and Removal steps for tubing
Figure 6: Visual guide for tubing installation and removal
Play video
Watch video online

Video 1: Demonstration of quick push-in tube connection and disconnection.

Operating Instructions

Once installed, the check valve automatically regulates the flow of fluid (clean air, vacuum, non-toxic gas) in one direction. Ensure that the system pressure and temperature remain within the specified operating ranges to prevent damage and ensure optimal performance.

The valve is designed to allow flow from port A to port B and block flow from port B to port A. Always verify the intended flow direction before integrating the valve into your pneumatic circuit.

Maintenance

  • Regularly inspect fittings and tubing for any signs of wear, damage, or leaks.
  • Ensure that the connections remain clean and free of debris. Debris can compromise the seal and lead to leaks or malfunction.
  • If a fitting needs to be replaced, follow the removal and installation instructions carefully.
  • Do not attempt to disassemble the valve, as it is not designed for user-serviceable parts.

Troubleshooting

Common Issues and Solutions:

  • Leakage at connection:
    • Ensure tubing is cut perpendicularly and free of scratches.
    • Verify tubing is fully inserted into the fitting until it locks.
    • Check if the tubing's outer diameter matches the fitting's specification.
    • Replace damaged tubing or fitting if necessary.
  • No flow or restricted flow:
    • Check if the valve is installed in the correct flow direction.
    • Verify that system pressure is within the valve's operating range.
    • Inspect for any blockages or debris inside the tubing or fitting.
  • Difficulty inserting/removing tubing:
    • For insertion, ensure tubing end is clean and not deformed.
    • For removal, ensure the release button is fully depressed.
    • Avoid excessive force; if still difficult, inspect for damage.

Specifications

Attribute Value
Brand NameYIDI
Model NumberSV-PL
TypeFittings, Hose to Male Thread
DesignElbow Check Valve
Connection WayOne-Touch Push in Quick Connection
MaterialNitrile Rubber, Plastic & Metal
Fluid TypeClean Air, Vacuum, No Toxic Gas
Applicable TubeSoft Nylon (PA), Polyurethane (PU)
Normal Operating Pressure0~10kgf/cm² (0~1.0MPa / 0~1.0bar)
Max. Operating Pressure1.3MPa
Negative Pressure-750mmhg (10Torr)
Ambient And Fluid Temperature0~60℃ (140℉)
CertificationCE, RoHS
OriginMainland China

Available Hose O.D. Sizes:

Hose Outer Diameter (O.D.) sizes: 4mm, 6mm, 8mm, 10mm, 12mm
Figure 7: Available Hose Outer Diameter (O.D.) Sizes

Available Male Thread Sizes:

Male Thread Sizes: M5*8, BSP(R) 1/8 inch, 1/4 inch, 3/8 inch, 1/2 inch
Figure 8: Available Male Thread Sizes
Specific model SVPL4-02 with dimensions
Figure 9: Example Model SVPL4-02 with approximate dimensions (1/4" male thread, 4mm hose)

User Tips

  • For optimal performance, always use tubing with the correct outer diameter for the fitting.
  • When installing, a slight twist while pushing can sometimes help seat the tube more easily.
  • Periodically check all connections in your pneumatic system for tightness and wear to prevent air leaks and maintain efficiency.
  • Store unused fittings in a clean, dry environment to prevent contamination.

Frequently Asked Questions (FAQ)

Q: What type of tubing is compatible with these fittings?
A: These fittings are compatible with Soft Nylon (PA) and Polyurethane (PU) tubes.
Q: Can these fittings be used with liquids?
A: No, these fittings are designed for pneumatic applications and are suitable for clean air, vacuum, and non-toxic gases only.
Q: How do I know the correct flow direction?
A: The check valve has internal mechanisms that allow flow in one direction only. Refer to the product diagrams (Figure 3 and 4) for visual indicators of the allowed flow direction (typically marked A to B).
Q: What should I do if a fitting leaks?
A: First, ensure the tubing is cut cleanly and inserted fully. Check for any damage to the tubing or the fitting. If the leak persists, the fitting or tubing may need to be replaced.

Warranty and Support

For detailed warranty information and customer support, please refer to the official YIDI Electric Store website or contact their customer service directly. A comprehensive user manual is also available in PDF format for download:

Download User Manual (PDF)

© 2024 YIDI Electric Store. All rights reserved.

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.

Was this page helpful?