Introduction
This manual provides instructions for the safe and effective use of the B-333A Body Shaping System. This device utilizes microcurrent technology for muscle stimulation, body shaping, and massage. It features 6 pulse output channels, allowing for simultaneous treatment of multiple body areas with 12 electrode pads. The system includes 6 unique function keys and 12 pre-set computer programs to cater to various needs, such as fat reduction, slimming, muscle exercise, and breast enhancement.
Safety Precautions
- Ensure your electrical outlet is well-grounded before operation.
- Always avoid placing electrode pads directly on the heart area.
- Do not place electrodes on the heart to avoid heart discomfort.
- The machine is prohibited for use by pregnant women, individuals with metal conductors in their bodies, patients with heart disease, skin disease, or other serious medical conditions.
- Use with caution on the face.
- If a warning voice sounds (indicating a mix-max button is not off), turn off all mix-max buttons and wait for 5 minutes until the warning voice stops.
Package Contents
The package includes the main control unit, various electrode pads (round and breast enhancement pads), connecting cables, and power adapter. The specific plug type (e.g., EU plug) will be indicated.

Setup Instructions
- Power Connection: Connect the power adapter to the device's power input (POWER AC110V/60HZ) and plug it into a grounded electrical outlet.

The device's power input and power switch, labeled POWER AC110V/60HZ. - Electrode Pad Preparation:
- Apply special emulsion or clear water evenly on the skin and the surface of the electrode pads. It is recommended to wet the pads for better conductivity.
- Ensure full contact between the skin and electrode pads. Dry or poor contact may cause a tingling or uncomfortable sensation.

A person applying conductive gel or water to the electrode pads before use. - Connecting Electrode Pads:
- Connect the electrode cables to the electrode pads.
- Insert the electrode cables into the output ports (CH1-CH6) on the main unit.

Detailed view of connecting electrode cables to the pads and then to the main unit's output ports. - Electrode Pad Placement: Place two different electrode pads from the same group on the body symmetrically or within a 5 cm range on the treating area. Secure them with a bandage if necessary. Refer to the "Electrode Pad Location" section for detailed diagrams.

Example of electrode pads applied to the waist area for EMS TENS massage. 
Electrode pads applied to the back for "Dredge Meridian" treatment, stimulating multiple meridians. 
Specialized breast enhancement pads applied to the chest area for micro-current stimulation.
Operating Instructions
Refer to the control panel diagram for button locations:

For a visual guide, please watch the official product video:
- Turn On: Turn on the machine. The timer display will initially show 30 minutes.
- Adjust Timer (Time Up/Down): Use the "Time Up/Down" buttons to adjust the work time. The maximum work time is 60 minutes.
- Select Program (P1-P4):
- Press the "SELECT" key to choose one of the four programs (P1, P2, P3, P4).
- Alternatively, press the "AUTO" key for the machine to automatically set the programs.
Program Descriptions:
- P1: Muscle release, pain relief, skin massage.
- P2: Breast area treatment, muscle tightening on legs/arms, buttocks, and udders upgrade.
- P3: Bionic movement (string drooping muscle, burn extra fatness).
- P4: Fat reduction, removal of fat cells through high-intensity massage for slimming.
Note: When a program is selected, the microcomputer automatically adjusts the operating speed for optimal effect.

Detailed explanation of the three pulse speeds (S, M, F) and four pulse programs (P1, P2, P3, P4) available on the device. - Adjust Speed (S, M, F): Press the "SPEED" key to choose the desired pulse speed:
- S (Slow): Suitable for people sensitive to electric current.
- M (Moderate): Suitable for experienced users.
- F (Fast): Suitable for those who exercise regularly or adapt well.
- Adjust Intensity (CH1-CH6 Mix-Max Adjuster): Use the individual "Mix-Max Adjuster" knobs for each channel (CH1-CH6) to set the desired output energy. Gradually increase the strength until you feel the current comfortably under the electrode pads.
- Start/Pause: Press the "START/PAUSE" key to begin or temporarily stop the operation.
- Turn Off: After the operation is complete, turn off the machine.
Electrode Pad Location
The following diagrams illustrate recommended electrode pad placements for various body areas. Remember that two different electrode pads from the same group should be placed symmetrically or within a 5 cm range.

Note: Non-woven gel patch physiotherapy is suitable for sensitive skin and offers high conductive efficiency. These can be applied to feet, upper arm, waist, shoulders, joints, and back.

Maintenance
- After each use, clean the electrode pads and the treated skin area.
- Store the device and accessories in a cool, dry place away from direct sunlight.
- Regularly inspect cables and pads for any signs of wear or damage. Replace if necessary.
Troubleshooting
- Warning Voice / Alarm:
- If the machine emits a warning voice, it indicates that one or more mix-max buttons are not turned off. To resolve this, turn off all mix-max buttons and wait for 5 minutes until the warning voice stops.
- Tingling or Uncomfortable Feeling:
- This can occur due to dry electrode pads or poor contact with the skin. Ensure special emulsion or clear water is applied to both the skin and pads, and that the pads are making full contact with the skin. You may also pre-treat the skin with a hot steamer for 10 minutes, followed by emulsion and massage for 5-10 minutes, then wipe clean with a hot towel or wet wipes before applying pads.
- No Output Energy:
- Check if the machine is properly powered on and if the cables are securely connected to both the device and the electrode pads. Ensure the intensity knobs (CH1-CH6) are adjusted to a suitable level.
Specifications
| Attribute | Value |
|---|---|
| Brand Name | foreverlily |
| Model Number | D-DYY250401 |
| Item Type | Massage & Relaxation |
| Application | BODY |
| Material | ABS |
| Power Supply | Direct Current |
| Voltage | 100~240V |
| Power | 10W |
| Frequency | 50/60Hz |
| Gross Weight (G.W) | 3KG |
| Net Weight (N.W) | 2.5KG |
| Dimensions (MEAS) | 30*28*20cm |
| Origin | Mainland China |
| Type | Currents | Frequency |
|---|---|---|
| P1 | 0.01~3MA | 0.5-4Hz |
| P2 | 0.015~10MA | 0.8~5Hz |
| P3 | 0.03~10MA | 1~7Hz |
| P4 | 0.05~11MA | 1.2~8Hz |
User Tips
- Many users find this equipment to be well-made and durable, with plenty of power for effective treatments.
- Ensure proper application of conductive gel or water to maximize effectiveness and comfort, as dry pads can cause tingling.
- The device comes with a good quantity of electrode pads. While specific replacement information is not provided, standard electrode pads compatible with 2.5mm jack connections are generally available from various suppliers.
- Experiment with different programs (P1-P4) and speed settings (S, M, F) to find what works best for your specific needs and comfort level.
Warranty and Support
For specific warranty information, technical support, or inquiries regarding replacement parts (such as electrode pads), please contact the seller or manufacturer directly. Refer to your purchase documentation for contact details.
A user manual in PDF format is also available for download: View User Manual (PDF)