1. Introduction
Thank you for choosing the MASTFUYI Digital Multimeter. This device is a versatile, auto-ranging tool designed for accurate measurement of various electrical parameters. It features a 9999-count True RMS display, capable of measuring AC/DC current, voltage, capacitance, and resistance. This manual provides essential information for safe and effective operation.

Figure 1: MASTFUYI Digital Multimeter
2. Safety Precautions
Special attention shall be paid to the fact that improper use may cause electric shock or damage to the meter. In use, it is required to follow the general safety regulations and fully observe the safety measures specified in this Manual. In order to make full use of the functions of the meter and ensure safe operation, you are required to read carefully and thoroughly, and follow, the instructions in this Manual.
2.1. Safety Instructions
- The user, when using the meter, must follow all standard safety procedures regarding:
- The prevention of electric shock.
- The prevention of misuse of the meter.
- For your personal safety, please use the meter and test probes accompanying the meter and make sure they are in good condition before use.
2.2. Safety Precautions
- The meter will produce errors even with large errors when the meter is being used near devices with large electromagnetic interference.
- Do not use the meter or measurement probe with appearance damage.
- Incorrect use of the meter may cause the safety function provided by the meter to fail.
- Extreme care must be taken when working around exposed conductors or bus bars.
- Do not use this meter near explosive gas, steam, or dust.
- Measurement must be performed by using correct input terminals and range.
- To prevent damage to the meter, the input value must not exceed the input limit value specified for each range.
- Never touch the input terminals not in use when the meter is connected to the line under test.
- Operate with care to prevent electric shock when the measured voltage exceeds 30V DC or 30V AC RMS.
- Place your fingers behind the measurement probe's protective ring when measuring.
2.3. Safety Symbols
| Symbol | Description |
|---|---|
| ⚠ | Warning, important safety sign. The instruction manual must be consulted before use to avoid damage to the device or its components. |
| ~ | AC (Alternating Current) |
| --- | DC (Direct Current) |
| ~--- | AC or DC |
| ␝ | Ground |
| CE | Compliant with European Union (EU) directives |
3. Package Contents
Upon opening your MASTFUYI Digital Multimeter package, you should find the following items:
- Digital Multimeter (Model FY159B or FY158A)
- Test Leads (Red and Black)
- User Manual
- Carrying Bag
- USB-Type-C Charging Cable (for FY159B/FY158B models)
- AAA Batteries (3x 1.5V, for FY158A model, not included in package)

Figure 2: Package contents for Model FY158A
Video 1: Unboxing and initial overview of the FY159B model.
4. Product Overview
The MASTFUYI Digital Multimeter is designed for ease of use and comprehensive functionality. Familiarize yourself with its components:

Figure 3: Schematic Diagram of the Meter (Model FY159B)
4.1. Description of Function Buttons
| Button/Feature | Function Description |
|---|---|
| 1. NCV Probes | Non-Contact Voltage detection. |
| 2. Flashlight | Provides illumination for working in dark areas. |
| 3. LED Screen | Digital display for measurements. |
| 4. Turn On/Off | Short press to turn on/off the meter. |
| 5. Select Function (SEL) | Short press to switch between different measurement modes (e.g., Resistance, Capacitance, Diode, LIVE). |
| 6. Data Hold (HOLD) / Flashlight | Short press to lock the current test data. Long press to enable or disable the flashlight function. |
| 7. H/L NCV | Short press to switch to induction measurement mode and select the sensitivity (High/Low) after another short press. |
| 8. Current Input (10A) | Input terminal for current measurements (up to 10A). |
| 9. COM Input | Common (negative) input terminal. |
| 10. V Ω°C/°F Hz Live Input | Input terminal for Voltage, Resistance, Temperature, Frequency, and Live wire measurements. |
5. Specifications
5.1. Comprehensive Indicators
- Safety Level: 600V CAT III, Pollution grade 2
- Altitude: < 2000m
- Operating Temperature: -50℃~1100℃
- Storage Temperature: -10℃~50℃
- Temperature Coefficient: Accurate to 0.1 / ℃ (<18℃ or >28℃)
- Maximum Allowable Voltage: Between the measuring terminal and the earth: 600V DC or 600V AC RMS
- Conversion Rate: About 3 times/second
- Display: 9999 counts LCD display, and the unit symbol is automatically displayed according to the function.
- Overload Indication: LCD will display "OL"
- Low Battery Indication: 🔋 symbol will appear when the battery voltage is lower than the normal working voltage.
- Input Polarity Indication: Displayed automatically.
- Auto Power-Off: The meter automatically shuts down if no signal input is made within 15 minutes.
- Power Supply: 1000mAh Lithium battery (for FY159B/FY158B) or 3*1.5V AAA batteries (for FY158A).
- Dimensions: 190mm x 30mm x 25mm
- Weight: 0.305 kg (without battery)
- Certifications: CE, FCC, RoHS
5.2. Measurement Ranges and Accuracy
| Function | Range | Accuracy | Overload Protection |
|---|---|---|---|
| DC Voltage (Auto) | 0~750V | ±(1.2% of reading + 3 words) | 250V DC/AC |
| AC Voltage (Auto) | 0.5V~1000V | ±(1.2% of reading + 3 words) | 250V DC/AC |
| DC Current | 10mA~10A | ±(1.2% of reading + 3 words) | FUSED MAX10A |
| AC Current | 10mA~10A | ±(1.2% of reading + 3 words) | FUSED MAX10A |
| Resistance | 0~100MΩ | ±(1.2% of reading + 3 words) | 250V DC/AC |
| Capacitance | 0~100mF | ±(4.0% of reading + 3 words) | 250V DC/AC |
| Frequency (via V gear) | 10Hz~1000Hz | ±(1.2% of reading + 3 words) | 250V DC/AC |
| Temperature | -50℃~1100℃ | For reference only | N/A |
| Diode | Approximate voltage drop | N/A | 250V DC/AC |
| Continuity | Buzzer sounds if < 30Ω | N/A | 250V DC/AC |
6. Setup
6.1. Battery Installation (FY158A)
For the FY158A model, which uses AAA batteries:
- Power off the meter.
- Unplug all test probes from the input jacks.
- Loosen the screws securing the battery cover with a screwdriver.
- Take off the battery cover.
- Remove any old batteries.
- Replace with new 3x 1.5V AAA batteries, ensuring correct polarity.
- Install the battery cover and tighten the screws.
6.2. Charging (FY159B/FY158B)
For models with a built-in 1000mAh Lithium battery (FY159B/FY158B), use the provided USB-Type-C cable for charging:
- Power off the meter.
- Unplug all test probes from the input jacks.
- Connect the USB-Type-C cable to the charging port on the multimeter and to a suitable USB power source.
- The charging indicator will show the charging status. Charge until full.
- Once fully charged, disconnect the cable.

Figure 4: Battery types for different models
Video 2: Demonstration of charging the FY159B model via USB-Type-C (0:13 - 0:25).
7. Operating Modes
The multimeter features an auto-ranging function that automatically recognizes AC/DC voltage, resistance, and continuity. For other functions, use the 'SEL' button to switch modes.
7.1. General Operation
- Power On/Off: Short press the power button to start the meter. It will enter auto-measurement mode. Short press again to turn off.
- Auto Measurement Mode: The meter automatically recognizes AC and DC voltage, resistance, and continuity. Connect the test leads to the circuit, and the meter will display the measurement.
- Function Selection: In auto mode, short press the 'SEL' button to cycle through capacitance, diode, and LIVE current mode.
- Data Hold: Short press the 'HOLD' button to lock the current test data. Press again to unlock.
- Flashlight: Long press the 'HOLD' button to enable or disable the flashlight.
- NCV (Non-Contact Voltage) Mode: Short press the 'H/L NCV' button to switch to induction measurement mode. Press again to select sensitivity (High/Low).

Figure 5: Product Operation Examples

Figure 6: Comprehensive Functions
7.2. Specific Measurement Examples
Connect the red test lead to the VΩ°C/°F Hz Live input terminal and the black test lead to the COM input terminal, unless otherwise specified.
- DC Voltage: Connect test leads across the DC voltage source. The meter will automatically detect and display the voltage. (See Video 2, 0:38 - 0:42)
- AC Voltage: Connect test leads across the AC voltage source. The meter will automatically detect and display the voltage and current frequency. (See Video 2, 0:43 - 0:47)
- DC Current: Insert the red test lead into the 10A input terminal and the black test lead into the COM terminal. Connect the meter in series with the DC circuit. (See Video 2, 0:50 - 0:55)
- AC Current: Insert the red test lead into the 10A input terminal and the black test lead into the COM terminal. Connect the meter in series with the AC circuit. (See Video 2, 0:56 - 1:03)
- Resistance: Connect test leads across the resistor. The meter will automatically detect and display the resistance. (See Video 2, 1:04 - 1:08)
- Continuity: Connect test leads across the component. If the resistance is less than 30Ω, the buzzer will sound. (See Video 2, 1:09 - 1:13)
- Capacitance: Short press 'SEL' to select capacitance mode. Connect test leads across the capacitor. (See Video 2, 1:14 - 1:21)
- Diode: Short press 'SEL' to select diode mode. Connect test leads across the diode. The meter will display the approximate forward voltage drop. (See Video 2, 1:22 - 1:26)
- Live Wire Check: Short press 'SEL' to select LIVE mode. Insert the red test lead into the VΩ°C/°F Hz Live input terminal. Touch the live wire with the red probe. The meter will indicate the live status. (See Video 2, 1:27 - 1:33)
- Temperature: Connect the temperature probe (if included) to the VΩ°C/°F Hz Live and COM input terminals. Place the probe in the environment to be measured. (See Video 2, 1:34 - 1:41)
- NCV (Non-Contact Voltage): Hold the NCV probe near an AC voltage source. The meter will indicate the presence and strength (Low/High) of the electric field. (See Video 2, 1:42 - 2:01)
8. Auxiliary Functions
This multimeter includes several additional features to enhance usability:
- LED Lighting: Provides illumination for working in dimly lit environments. Activated by long-pressing the 'HOLD' button.
- Backlit Display: Ensures readability in various lighting conditions.
- Data Hold: Allows you to freeze the current measurement on the screen for easy recording. Activated by short-pressing the 'HOLD' button.
- Auto Power-Off (15 minutes): The meter will automatically shut down after 15 minutes of inactivity to conserve battery life.
- Low Battery Indication: An icon will appear on the screen to alert you when the battery is low and needs replacement or recharging.
- Polarity Display: Automatically indicates the polarity of DC measurements.
- Overrange Display: Displays "OL" when the measurement exceeds the selected range.

Figure 7: Auxiliary Measurement Functions
9. User Tips
- Always ensure test leads are securely connected before taking measurements.
- For models requiring AAA batteries (FY158A), remember to purchase them separately as they are not included.
- The auto-ranging feature is convenient, but for precise measurements in specific ranges, manually selecting the function via the 'SEL' button can be beneficial.
- Utilize the flashlight function when working in poorly lit areas to improve visibility and safety.
10. Maintenance
10.1. General Maintenance
- To avoid shock or meter damage, keep the meter away from any moisture.
- Before opening the case of the meter, disconnect the cable between the test probe and the input signal.
- Clean the meter case regularly with a damp cloth and a small amount of detergent instead of abrasives or chemical solvents.
- Dirty or wet input jacks may affect readings. To clean input jacks:
- Turn off the meter and unplug all measurement probes from the input jacks.
- Remove all dirt from the jacks.
- Clean each jack socket by using cotton balls dipped in detergent or lubricant, as the lubricant can prevent socket contamination.
10.2. Battery Replacement/Recharge
- Replace or recharge the battery immediately after the low battery symbol (🔋) appears on the meter display.
- Failure to do so may lead to incorrect readings, electric shock, or personal injury due to wrong measurements.
- Before opening the battery cover to replace a new battery, power off the meter and check that the test probes are disconnected from the measurement circuit to avoid electric shock or personal injury.
11. Troubleshooting
If you encounter issues with your multimeter, consider the following:
- No Display/Power On: Check battery level. For FY158A, ensure batteries are correctly installed and not depleted. For FY159B/FY158B, ensure the device is charged.
- Inaccurate Readings: Ensure test leads are properly connected and not damaged. Verify the correct measurement mode is selected. Clean input jacks if dirty.
- "OL" Display: This indicates an overrange condition. The measured value exceeds the meter's maximum capacity for the current range. Switch to a higher range if available, or confirm the circuit is within the meter's specifications.
- No Continuity Beep: Ensure the continuity mode is selected and the resistance is below 30Ω.
For more detailed troubleshooting, please refer to the full user manual PDF.
12. Warranty and Support
This product is covered by a manufacturer's warranty. Please retain your proof of purchase for any warranty claims.
For technical support, warranty information, or service inquiries, please contact the seller or refer to the official product documentation.
13. Additional Resources
For a complete and detailed guide, including comprehensive diagrams and safety information, please refer to the official user manual PDF: