Contents

Beok Tuya Underfloor Heating Hub Controller User Manual

Models: CCT-25, CCT-28

1. Product Overview

The Beok Tuya Underfloor Heating Hub Controller is designed for floor heating systems. It receives control signals from room thermostats to manage actuators for corresponding floor heating circuits. This hub controller supports both power linkage and non-power linkage control modules, allowing it to control external components such as water pumps (or mixing units, main valves) and boilers (or heat pumps) with external control functionality.

Beok Tuya Underfloor Heating Hub Controller system setup with thermostats and actuators
Figure 1: Overview of the Beok Tuya Underfloor Heating Hub Controller system, showing connection to thermostats and actuators.

The CCT-25 model features 5 channels, while the CCT-28 model offers 8 channels, allowing control over multiple heating zones.

Diagram showing the hub controller managing heating in up to 8 rooms
Figure 2: The hub controller can manage heating in up to 8 separate rooms or zones.

2. Specifications

2.1. Technical Parameters

ParameterValue
Power Supply100-240VAC, 50/60Hz 10A
Passive Output (Boiler)8A
Circulating Pump Output250VAC, 8(5)A
No Power Linkage1 normally open common terminal
Number of Circuits8 loops or 5 loops (depending on model)
Max Number of Actuators per Circuit3 pcs
Output Delay200s
Wattage2W
WIFI2.4G
CertificationCE
OriginMainland China

2.2. Product Dimensions

Dimensions of the hub controller: 110mm height, 177mm width, 35mm depth
Figure 3: Product dimensions. The hub controller measures approximately 110mm in height, 177mm in width, and 35mm in depth.

3. Installation

3.1. Safety Precautions

  • Ensure power is disconnected before any installation or wiring.
  • Installation should be performed by a qualified electrician.
  • This product is only suitable for normally closed actuators. Using normally open actuators may lead to abnormal operation.
  • Strictly observe the technical parameters of the equipment. The load of each interface must not exceed the specified technical parameters.

3.2. Wiring Instructions

The hub controller facilitates connections for thermostats, actuators, gas boilers, and circulating pumps. Refer to the detailed wiring diagrams below for proper connection.

Detailed internal wiring diagram of the hub controller showing terminals for room light, pump light, boiler light, power light, fuse, outputs for thermostats and actuators, gas boiler (dry contact), pump, and 220V power.
Figure 4: Internal wiring diagram of the hub controller. It includes terminals for Room Light, Pump Light, Boiler Light, Power Light, a Fuse, 8 or 5 Outputs/Channel (up to 1 Thermostat, up to 3 Actuators), Gas Boiler (dry contact), Pump, and 220V Power.
Diagram illustrating that up to 3 actuators can be connected to one output channel of the hub controller.
Figure 5: Up to 3 actuators can be connected to a single output channel of the hub controller.

Wiring Steps (Refer to video for visual guide):

  1. Open the hub controller casing by unscrewing the cover.
  2. Connect the main power supply to the designated terminals (L and N).
  3. Connect the thermostat to the hub controller. Ensure correct wiring for live (L), neutral (N), and control signals.
  4. Connect the NC (Normally Closed) actuator to the appropriate output terminals on the hub controller.
  5. Connect the gas boiler (dry contact) and circulating pump to their respective terminals on the hub controller.
  6. Secure all wire connections firmly using a screwdriver.
  7. Close the hub controller casing.

3.3. Actuator Models

  • RZ-D07-230NC Actuator:
    RZ-D07-230NC Actuator
    Figure 6: RZ-D07-230NC Actuator.
  • CCT-28 Actuator:
    CCT-28 Actuator
    Figure 7: CCT-28 Actuator.

3.4. Installation and Wiring Demonstration Video

Video 1: This video demonstrates the physical differences between CCT-25 (5 channels) and CCT-28 (8 channels) hub controllers, and provides a step-by-step guide on wiring a thermostat and NC actuator to the hub. It also shows the system's response to heating commands, including the activation of the boiler and pump.

4. Operating Instructions

4.1. Working Principle

When a room requires heating, the corresponding room thermostat sends a signal to the hub controller. This activates the actuator for that specific floor heating circuit, and its indicator light turns on. If no signal is received from a thermostat, the corresponding actuator is turned off, and its indicator light is off.

Upon receiving a heating signal from any thermostat, and after a preset delay time (200s), the hub activates the water pump (if power linkage is enabled) and the boiler (if non-power linkage is enabled), and their respective linkage indicators light up. When all thermostats cease sending heating signals, the water pump and boiler will turn off, and their linkage indicators will also turn off.

4.2. Basic Operation

  1. Power On: Once wired correctly, connect the power supply. The power indicator light on the hub controller will illuminate.
  2. Initiate Heating: Adjust the room thermostat to a temperature higher than the current room temperature. The thermostat will send a heating signal to the hub.
  3. System Response: The corresponding indicator light on the hub for that zone will turn on. After approximately 3 minutes (output delay), the boiler and pump will start working, and their indicator lights will also light up. The normally closed actuator will open to allow hot water flow.
  4. Stop Heating: Adjust the room thermostat to a temperature lower than the current room temperature or turn off the heating function. The indicator light on the hub will immediately turn off. The NC actuator will slowly close, stopping the hot water flow.

5. Maintenance

  • Regularly check all wiring connections to ensure they are secure and free from corrosion.
  • Keep the hub controller clean and free from dust and debris. Use a soft, dry cloth for cleaning.
  • Do not expose the device to excessive moisture or extreme temperatures.
  • If any part of the system appears damaged or is not functioning correctly, consult a qualified technician.

6. Troubleshooting

  • No Power: Check the main power supply connection and ensure the power indicator light on the hub is on. Verify the fuse in the hub controller (refer to Figure 4).
  • Heating Not Activating: Ensure the thermostat is set correctly and sending a heating signal. Check the indicator light for the corresponding zone on the hub. Verify actuator connections.
  • Boiler/Pump Not Starting: If the zone indicator light is on but the boiler/pump is not activating after the delay, check their wiring connections to the hub. Ensure the boiler and pump are functioning independently.
  • Actuator Not Opening/Closing: Confirm the actuator is a normally closed (NC) type. Check its wiring and ensure it receives power from the hub.
  • System Malfunction: If the system behaves unexpectedly, power cycle the hub controller (turn off and on the main power). If issues persist, consult the full user manual or professional assistance.

7. User Tips

  • Actuator Capacity: Each channel on the hub controller can support up to 3 actuators. Plan your heating zones accordingly.
  • Thermostat Compatibility: The hub controller is designed to work with various thermostats, including those with 3A or 16A ratings. Ensure your thermostat's output matches the hub's input requirements.
  • Wiring Clarity: For complex installations, label your wires clearly before connecting them to the hub to simplify troubleshooting and future maintenance.

8. Frequently Asked Questions

Q: How many actuators can I connect to one channel?
A: You can connect up to 3 actuators per channel.
Q: Is this hub functional with 3A or 16A thermostats?
A: Yes, the hub controller is designed to be functional with both 3A and 16A thermostats.

9. Warranty and Support

For detailed warranty information and further technical support, please refer to the official Beok website or contact customer service.

A comprehensive user manual in PDF format is available for download: