1. Introduction
Thank you for choosing the Aramox Angle Stop Valve. This manual provides essential information for the safe and effective installation, operation, and maintenance of your new valve. Please read this manual thoroughly before installation and keep it for future reference.

Figure 1: Aramox Angle Stop Valve (Overall View)
2. Safety Information
- Always turn off the main water supply before attempting any plumbing work.
- Wear appropriate personal protective equipment (PPE), such as safety glasses and gloves, during installation.
- Ensure all connections are properly sealed and tightened to prevent leaks.
- If you are unsure about any installation steps, consult a qualified plumber.
3. Package Contents
- 1 x Aramox Angle Stop Valve
4. Features
- Standard Thread: Equipped with standard G1/2 inch (DN15) male thread and G3/4 inch (DN20) male thread, ensuring compatibility with various plumbing systems.
- Quarter Turn Valve: The ball valve design allows for quick and effortless on/off control of water flow.
- Brass Construction: Made from durable brass material, offering high hardness, resistance to pressure, and corrosion for long-lasting performance.
- Versatile Usage: Suitable for use in toilets, kitchen sinks, bathroom sinks, and other plumbing fixtures.
- Leakage Proof: Precision threading and robust brass construction ensure a tight and secure connection, minimizing the risk of leaks.
5. Setup and Installation
Follow these steps for proper installation:
- Prepare: Ensure the main water supply to the area where the valve will be installed is turned off. Drain any remaining water from the pipes.
- Inspect: Carefully inspect the valve for any damage before installation.
- Apply Sealant: Apply plumber's tape (PTFE tape) or appropriate thread sealant to the male threads of the G1/2 (DN15) connection that will attach to your water supply line or fixture.
- Connect Valve: Screw the G1/2 (DN15) male thread of the angle stop valve onto the corresponding female connection of your water supply pipe or fixture. Hand-tighten first, then use a wrench to tighten securely, being careful not to overtighten.
- Connect Appliance/Hose: Connect your appliance hose (e.g., toilet supply line, faucet supply line) to the G3/4 (DN20) male thread of the angle stop valve. Ensure the connection is secure.
- Check Connections: Double-check all connections for tightness.
- Restore Water Supply: Slowly turn on the main water supply.
- Leak Test: Carefully inspect all connections for any signs of leaks. If leaks are detected, turn off the water supply, tighten the connections, and re-test.


Figure 2: G1/2 DN15 Male Thread (Left) and G3/4 DN20 Male Thread (Right)
6. Operating Instructions
The Aramox Angle Stop Valve features a quarter-turn handle for easy operation:
- To Open the Valve (Water Flow ON): Turn the handle so it is parallel with the direction of the water flow.
- To Close the Valve (Water Flow OFF): Turn the handle so it is perpendicular to the direction of the water flow.

Figure 3: Internal Ball Valve Mechanism
7. Maintenance
- Regular Inspection: Periodically check the valve and its connections for any signs of leaks, corrosion, or damage.
- Cleaning: Clean the exterior of the valve with a soft cloth and mild soap solution if necessary. Avoid abrasive cleaners that could damage the finish.
- No User-Serviceable Parts: This valve contains no user-serviceable internal parts. Do not attempt to disassemble the valve, as this may void any implied warranty and could lead to leaks.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Water leakage at connections | Loose connections, insufficient thread sealant, cross-threaded connection, imprecise threading. | Turn off water supply. Tighten connections. Reapply thread sealant. Ensure threads are aligned correctly before tightening. If threads are damaged, valve may need replacement. |
| Difficulty turning handle | Debris in valve, mineral buildup, valve not fully open/closed. | Ensure valve is fully open or closed. If persistent, valve may need replacement. |
| No water flow | Valve is closed, upstream water supply is off, blockage. | Ensure valve is fully open. Check main water supply. Check for blockages in pipes or appliance. |
| Small gap visible on valve body | Manufacturing tolerance, potential defect. | Monitor for leaks. If leakage occurs, replace the valve. |
9. Specifications
| Attribute | Detail |
|---|---|
| Brand Name | Aramox |
| Model Number | Angle Stop Valve |
| Material | Brass |
| Structure | Ball |
| Port Size | G1/2 (DN15) Male Thread x G3/4 (DN20) Male Thread |
| Media | Water |
| Temperature of Media | Normal Temperature |
| Pressure | Low Pressure |
| Power | Manual |
| Is Smart Device | No |
| Certification | NONE |
10. User Tips
- When installing, ensure threads are aligned correctly to prevent cross-threading and potential issues with connection precision.
- After installation, slowly turn on the water supply and carefully inspect all connections for any signs of leakage, especially around the threaded areas.
- Periodically check the valve for any small gaps or signs of wear that might develop over time, and address any leaks promptly.
11. Warranty and Support
For warranty information or technical support, please refer to your purchase documentation or contact the retailer where you purchased this product. Keep your proof of purchase for any warranty claims.