Y&H MPS-VX 4KW-24V-110V

Contents

Y&H 4KW Hybrid Solar Inverter User Manual

Model: MPS-VX 4KW-24V-110V

1. Introduction

1.1 About This Manual

This manual describes the assembly, installation, operation, and troubleshooting of the Y&H 4KW Hybrid Solar Inverter. Please read this manual carefully before installation and operation. Keep this manual for future reference. It provides safety and installation guidelines as well as information on tools and wiring.

1.2 Safety Instructions

WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries, and all appropriate sections of this manual.
  2. CAUTION: To reduce the risk of injury, charge only deep-cycle lead-acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce the risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION: Only qualified personnel can install this device with a battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation, follow required specifications to select appropriate cable size.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts, which could cause an explosion.
  9. Strictly follow the installation procedure when disconnecting AC or DC terminals. Refer to the INSTALLATION section.
  10. GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a permanent grounded wiring system. Comply with local requirements and regulations.
  11. NEVER cause AC output and DC input short-circuited. Do NOT connect to the mains when DC input short circuits.
  12. Warning!! Only qualified service persons are able to service this device. If errors persist after troubleshooting, send this inverter/charger back to a local dealer or service center.

1.3 Product Overview

This is a multi-function inverter/charger, combining functions of inverter, MPPT solar charger, and battery charger to offer uninterruptible power support. Its comprehensive large LCD display offers user-configurable and easy-accessible touch button operation.

1.3.1 Key Features

  • Off-grid solar inverter
  • No battery function available (can operate without battery)
  • Adjustable AC voltage (100VAC, 110VAC, 120VAC) under Battery Mode
  • Utility power, battery, and PV power complement each other
  • Pure sine wave solar inverter
  • Unique glass top cover design with 6.25-inch LCD display and touchable buttons
  • Built-in 150A MPPT solar charger (Max PV 7200W)
  • High PV input range from 55V-450Vdc
  • Smart battery charger design for optimized battery performance
  • Configurable AC/Battery input priority via LCD setting
  • Auto restart while PV is recovering
  • Over-load, over-temperature, and output short circuit protection
  • Cold restart function
  • Built-in lithium battery automatic activation
  • Communication with RS232/RS485
  • WiFi monitoring function (optional)
  • Anti-dust kit for harsh environments (optional)
  • Restore default settings with one click
Y&H 4000W Hybrid Solar Inverter Key Features

Figure 1.1: Key Features of the 4000W Hybrid Solar Inverter
This image highlights the inverter's capabilities: 4KW 24V, 55-350V PV Input, 5600W Max PV Array Power, DC 24V Battery voltage, and MPPT 140A Charging current.

1.3.2 Basic System Architecture

The inverter/charger can be integrated into a system that includes a generator or utility power, and optional PV modules. It can power various home or office appliances, including motor-type appliances like refrigerators and air conditioners.

Hybrid Power System Diagram

Figure 1.2: Hybrid Power System Overview
This diagram illustrates the basic connections: Solar Power (option) to Solar Inverter, which then connects to Home Appliances. A Generator or Utility can also feed into the system, and External Battery packs (BATTERY) can be connected.

2. Product Overview (Physical)

The following diagram and list detail the components and connections on the inverter unit.

Inverter Front and Bottom Panel Overview

Figure 2.1: Inverter Front and Bottom Panel Layout
This image shows the front panel with LCD display and touch buttons, and the bottom panel with various input/output ports.

  1. LCD display
  2. Status indicator
  3. Charging indicator
  4. Fault indicator
  5. Function touch buttons
  6. Power on/off switch
  7. AC input
  8. AC output
  9. PV input
  10. Battery input
  11. RS485/RS232 communication port

3. Setup and Installation

3.1 Unpacking and Inspection

Before installation, inspect the unit. Ensure nothing inside the package is damaged. The package should contain: The inverter unit (x1) and User manual (x1).

3.2 Preparation

Before connecting all wirings, remove the bottom cover by unscrewing two screws.

3.3 Mounting the Unit

Consider the following points for installation:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install at eye level for LCD display readability.
  • Ambient temperature should be between 0°C and 55°C for optimal operation.
  • Adhere to vertical wall installation.
  • Maintain clearances (50cm top/bottom, 20cm sides) for heat dissipation and wire access.

SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

3.4 Wiring and Technical Specifications Diagram

This diagram provides a comprehensive overview of all connections and their associated technical specifications. Please review it carefully before proceeding with any wiring.

Wiring and Technical Specifications Diagram

Figure 3.1: Comprehensive Wiring and Technical Specifications
This diagram details the following connections and specifications:

  • Battery Type: Lead-Acid (AGM, FLD, USE) and Lithium battery
  • Battery voltage: 24V
  • Wire Size: 2AWG
  • Cable: 35mm²
  • Max AC Input Voltage: 150Vac
  • Charging Current: 110A
  • Suggested cable: 8AWG
  • Recommended breaker: 40A
  • AC Output Power: 4.0KW
  • AC Output Voltage: 120Vac
  • Suggested cable: 8AWG
  • Recommended breaker: 40A
  • PV Power: 5600W
  • Max. PV Open Circuit Voltage: 350V
  • PV MPPT Voltage Range: 55V - 1280VDC (Note: PDF states 55-350Vdc, follow PDF for operational range)
  • Start-up voltage (initial charging): 55Vdc
  • Suggested cable: 12AWG
  • It is recommended to connect solar panels in series.
  • Wire Color Code: Live wire/Positive wire (Red), Neutral wire/negative wire (Blue/Black), Earth (wire) (Green/Yellow).

3.5 Battery Connection

CAUTION: For safety and regulation compliance, install a separate DC over-current protector or disconnect device between battery and inverter. Over-current protection is always required.

WARNING! All wiring must be performed by qualified personnel. Use appropriate cable for battery connection to reduce risk of injury.

ModelTypical AmperageBattery CapacityWire SizeCable mm²Torque Value
3.0KW 24V110A100AH/200AH1*4AWG222~3 Nm
4.0KW 24V150A200AH1*2AWG352~3 Nm

3.5.2 Connection Steps

  1. Assemble battery ring terminal based on recommended cable and terminal size.
  2. Connect all battery packs as required. (Use sealed lead-acid, GEL/AGM, or lithium batteries only).
  3. Insert the ring terminal of the battery cable flatly into the battery connector of the inverter. Ensure bolts are tightened with a torque of 2-3 Nm. Verify correct polarity at both the battery and inverter/charger.

WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.

CAUTION: Do not place anything between the flat part of the inverter terminal and the ring terminal. Overheating may occur. Do not apply anti-oxidant substance on terminals before connecting tightly. Before final DC connection, ensure positive (+) is connected to positive (+) and negative (-) to negative (-).

3.6 AC Input/Output Connection

CAUTION: Install a separate AC breaker between the inverter and AC input power source. Recommended AC breaker: 32A for 3.0KW, 40A for 4.0KW. Do NOT mis-connect input and output connectors.

WARNING! All wiring must be performed by qualified personnel. Use appropriate cable for AC input connection.

3.6.1 Suggested Cable Requirement for AC Wires

ModelGaugeTorque Value
3.0KW10 AWG1.2~1.6 Nm
4.0KW8 AWG1.4~1.6 Nm

3.6.2 Connection Steps

  1. Before making AC input/output connection, open DC protector or disconnector first.
  2. Remove insulation sleeve 10mm for six conductors. Shorten phase L and neutral conductor N by 3mm.
  3. Insert AC input wires according to polarities (L→LINE: brown or black; N→Neutral: blue or white) and tighten terminal screws.
  4. Insert AC output wires according to polarities. Connect PE protective conductor (Ground: green) first.
  5. Ensure all wires are securely connected.

WARNING: Be sure that AC power source is disconnected before attempting to hardwire it to the unit.

CAUTION: Important! Connect AC wires with correct polarity. Reversed L and N wires may cause utility short-circuited in parallel operation. For appliances like air conditioners, allow 2-3 minutes for restart to balance refrigerant gas. Check if appliances have time-delay function.

3.7 PV Connection

CAUTION: Install a DC circuit breaker between the inverter and PV modules.

WARNING! All wiring must be performed by qualified personnel. Use appropriate cable for PV module connection.

3.7.1 Suggested Cable Requirement for PV Module Connection

ModelWire SizeCable (mm²)Torque Value (max)
3.0KW/4.0KW1 x 12AWG41.2 Nm

3.7.2 PV Module Selection

Consider the following parameters:

  • Open circuit Voltage (Voc) of PV modules must not exceed max. PV array open circuit voltage of inverter.
  • Open circuit Voltage (Voc) of PV modules should be higher than min. PV Array MPPT Voltage range.
INVERTER MODEL3.0KW4.0KW
Max. PV Array Open Circuit Voltage350Vdc
PV Array MPPT Voltage Range55Vdc~350Vdc

3.7.3 Connection Steps

  1. Remove insulation sleeve 10 mm for positive and negative conductors.
  2. Check correct polarity of connection cable from PV modules and PV input connectors. Connect positive (+) to positive (+) and negative (-) to negative (-).
  3. Ensure wires are securely connected.

3.8 Final Assembly

After connecting all wirings, replace the bottom cover by screwing the two screws.

4. Operating Instructions

4.1 Power ON/OFF

Once the unit is properly installed and batteries are connected, press the On/Off switch (located on the side of the case) to turn on the unit.

4.2 Operation and Display Panel

The front panel includes three indicators, four function keys, and an LCD display to show operating status and input/output power information.

4.2.1 LED Indicators

IndicatorColorStatusMessage
AC/INVGreenSolid On
Flashing
Output powered by utility (Line mode)
Output powered by battery or PV (Battery mode)
CHGGreenSolid On
Flashing
Battery fully charged
Battery is charging
FAULTRedSolid On
Flashing
Fault occurs in inverter
Warning condition occurs in inverter

4.2.2 Function Keys

Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm selection in setting mode or enter setting mode

4.3 LCD Display Icons

The LCD displays various icons indicating input source, configuration, fault information, output, battery status, load level, operation mode, and mute status. Refer to the full user manual (PDF) for a detailed description of each icon.

4.4 LCD Setting

Press and hold the ENTER button for 3 seconds to enter setting mode. Use UP/DOWN to select programs, then ENTER to confirm or ESC to exit. Key configurable settings include: Output source priority (Solar first, SBU priority), Maximum charging current, AC input voltage range, Power saving mode, Battery type (AGM, Flooded, Lithium, User-Defined), Output voltage, Output frequency, Bulk/Floating charging voltage, Low DC cut-off voltage, and Battery equalization settings. For detailed program settings and options, please refer to the comprehensive user manual PDF.

4.5 Lithium Battery Connection and Settings

If using lithium batteries, ensure they are matched with the BMS communication protocol. Connect the RJ45 connector from the battery to the COMM port on the inverter. Set the battery type to

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.