1. Important Safety Information
Disclaimer: This item may be intended for use by professional health care providers only. The seller may ask you to provide evidence that you are a qualified health care provider and are entitled to buy and use certain items in your country.
- Always ensure the power supply matches the specifications listed in this manual.
- Do not attempt to open or repair the device yourself. Refer all servicing to qualified personnel.
- Keep the light away from water or other liquids to prevent electric shock.
- Ensure proper ventilation around the unit during operation.
- Avoid direct eye exposure to the LED light for prolonged periods.
- Use only approved accessories and replacement parts.
2. Product Overview
The COXO CX249-23 Dental Operating Light is designed to provide optimal illumination for dental procedures. It features 6 high-power LEDs, a double control system (sensor and switch), and flexible positioning capabilities.
3. Setup and Installation
The COXO CX249-23 Dental Operating Light is intended for professional installation. Ensure the mounting location is structurally sound and can support the weight of the unit. The light is designed with a joint dimension of ø22mm for integration into dental units.
- Unpack all components and verify against the packing list.
- Mount the light arm securely to the dental unit using the ø22mm joint.
- Connect the power supply cable to the dental unit's power source, ensuring it meets the AC12-24V 50/60Hz requirement.
- Ensure all connections are firm and secure.
- Perform an initial functional test before clinical use.
4. Operating Instructions
The CX249-23 features a double control system, allowing operation via both a sensor and physical switches.
4.1 Controls
- Power Button: Press to turn the light ON/OFF.
- Light Intensity Adjustment: Use the designated buttons to increase or decrease the light intensity steplessly. The light intensity can exceed 30000 Lux.
- Color Temperature Adjustment: Adjust the color temperature within the range of 4000K-6400K to suit procedural needs and reduce eye strain during long operations. The optimized color temperature range is 5500K-6500K, similar to natural light.
- Sensor Control: Wave your hand within the inductive distance (0-90mm) to activate or deactivate the light without physical contact. The interaction range for the sensor is 20-80mm.
4.2 Positioning the Light
The CX249-23 offers free movement across 3 axes, allowing precise positioning of the light to the desired area.
- Vertical Adjustment: Adjust the light head up or down along its vertical axis.
- Horizontal Rotation: Rotate the light head horizontally to cover the treatment area.
- Angular Tilt: Tilt the light head to direct the beam precisely.
The light is factory calibrated at 700mm (average arm length) to produce a precise 80x160mm rectangular light pattern with uniform intensity. Illumination outside this pattern is significantly lower to prevent glare in the patient's eyes.
5. Maintenance and Cleaning
Regular maintenance ensures the longevity and optimal performance of your dental operating light.
- Cleaning Handles: The handles of the CX249-23 are removable for easy cleaning and sterilization. Detach the handles, clean them with a suitable disinfectant, and reattach securely.
- General Cleaning: Wipe down the exterior surfaces of the light head and arm with a soft cloth dampened with a mild, non-abrasive disinfectant. Avoid spraying liquids directly onto the light.
- Lens Cleaning: Gently clean the LED lens with a soft, lint-free cloth to ensure maximum light output.
- Inspection: Periodically inspect all moving parts and connections for any signs of wear or damage.
6. Troubleshooting
If you encounter any issues with your CX249-23 Dental Operating Light, refer to the following common troubleshooting steps:
- Light does not turn on:
- Check if the power cable is securely connected to both the light and the power source.
- Verify that the power supply to the dental unit is active.
- Ensure the power button on the light is pressed.
- Light intensity is low or inconsistent:
- Check if the light intensity settings are adjusted correctly.
- Ensure the LED lens is clean and free from obstructions.
- Sensor control is unresponsive:
- Ensure there are no obstructions blocking the sensor.
- Verify that your hand movement is within the specified inductive distance (0-90mm) and interaction range (20-80mm).
For any persistent issues or problems not listed here, please contact qualified service personnel or your authorized dealer.
7. Specifications
| Parameter | Value |
|---|---|
| Power Supply | AC12-24V 50/60Hz |
| Absorbed Power | 15VA |
| LED Light Quantity | 6 PCS |
| Light Intensity | >30000Lux |
| Dimension of Pattern (at 700mm) | <180×90mm |
| Color Temperature | 4000-6400K |
| CRI (Color Rendering Index) | 85% |
| Shaft Dimensions | 22mm |
| Inductive Distance | 0-90mm |
| Shadow (Solution) | ø12mm |
| Eye Intensity (Lux) | 200lux |
| Interaction Range (Sensor) | 20-80mm |
| Joint Dimension | ø22 |
| Weight (kg)/PCS | 1.6 |
8. User Tips
No specific user tips from reviews or Q&A are available at this time. Always refer to the operating instructions for optimal performance and safety.
- For best visual comfort and reduced eye strain during long procedures, utilize the adjustable color temperature feature to find the optimal setting for your environment.
- Regularly clean the sensor area to ensure consistent and responsive hands-free operation.
9. Warranty and Support
For warranty information, technical support, or service inquiries regarding your COXO CX249-23 Dental Operating Light, please contact your authorized dealer or the manufacturer directly. Keep your purchase receipt and product serial number handy when contacting support.