JIKONG JK-PB2A16S30P V19

Contents

JIKONG V19 Household Energy Inverter BMS User Manual

Model: JK-PB2A16S30P V19

For 8S/24V to 16S/48V Li-ion/LiFePO4/LTO Battery Systems

1. Introduction

The JIKONG V19 Household Energy Inverter BMS (Battery Management System) is a sophisticated management system designed for large-capacity series lithium battery packs. It offers comprehensive features including voltage acquisition, high-current active balancing, overcharge/over-temperature protection, coulomb metering, Bluetooth communication, and host computer monitoring. This BMS is suitable for various battery chemistries, including lithium iron phosphate (LiFePO4), ternary lithium (Li-ion), and lithium titanate (LTO) batteries.

The protection board utilizes energy transfer active balancing technology, ensuring maximum battery consistency, improved battery range, and delayed battery aging. It supports a maximum continuous 2A balance current.

A dedicated mobile application (APP) is available for both Android and iOS, allowing users to monitor battery status, modify parameters, and control charge/discharge switches via Bluetooth. The compact size, simple operation, and full functionality make it ideal for high-power energy storage, base station backup power supplies, and solar power station battery packs.

2. Package Contents

Upon unboxing your JIKONG V19 BMS, please verify that all components are present and in good condition. The standard package typically includes the following items:

Video: JIKONG V19 BMS Unboxing and Overview. This video demonstrates the unboxing process and provides a visual overview of the main BMS unit and included accessories, followed by demonstrations of app and inverter settings.
  • JIKONG V19 BMS Main Board
  • Interface Board
  • Adapter
  • RJ45 Network Cable (400mm)
  • Switch (500mm)
  • Heating Adapter Cable x1 (170mm)
  • Cells total B+ Cable (500mm)
  • Sampling Line A (900mm)
  • Sampling Line B (900mm)
  • Sampling Line C (900mm)
  • Adapter Cable A (300mm)
  • Adapter Cable B (300mm)
  • Adapter Cable C (300mm)
  • Optional: JIKONG 4.3 Inch LCD Display
JIKONG V19 BMS board with LCD display
Figure: JIKONG V19 BMS Main Board and Optional LCD Display. This image shows the main BMS board and the separate 4.3-inch LCD display unit.
JIKONG 4.3 Inch Display unit with wiring harness
Figure: JIKONG 4.3 Inch Display Unit. The optional 4.3-inch LCD display unit with its wiring harness, providing real-time battery information.

3. Product Overview and Features

The JIKONG V19 BMS is designed to provide robust protection and efficient management for your battery system. Key features include:

3.1. Functional Characteristics

  • LED Bluetooth status indicator
  • APP Bluetooth remote operation
  • Battery capacity calculation
  • Supports PC operations
  • High precision voltage acquisition (±3mV)
  • High precision current acquisition
  • Support information screen display
  • Accurate time logging
  • Support RS485 communication
  • Support CAN communication
  • Support heating function
  • Alarm dry contact function
  • Charge overcurrent protection
  • Charge overvoltage protection
  • Charge over temperature protection
  • Low temperature protection during charge
  • Discharge overcurrent protection
  • Discharge undervoltage protection
  • Discharge over temperature protection
  • Short circuit protection
  • Battery parallel current limiting function

3.2. Structural Block Diagram

JIKONG V19 BMS board with QR code for JK-BMS.com
Figure: JIKONG V19 BMS Main Board. This image shows the top view of the BMS main board, highlighting the QR code for the official website and various connection points.

The BMS integrates various modules for comprehensive battery management. These include active balancing collection circuits, NTC temperature monitoring, MOS drivers, current limiting circuits, current sampling, and communication interfaces (Bluetooth, RS485, CAN, LCD screen interface, dry contacts).

3.3. Application Scenarios

JIKONG Home Energy Storage BMS V19 Version application scenarios
Figure: Application Scenarios. The JIKONG V19 BMS is suitable for home energy storage systems, communication base stations, building energy storage, industrial energy storage, and office backup power.

4. Specifications

4.1. Basic Parameters

ParameterValueUnit
Supply voltage20-70V
Standby power consumption12mW
Operating power consumption1100mW
Operating temperature-30-70°C
Maximum number of collection strings16S
Maximum balancing current2A
Maximum charging current300A
Maximum discharge current300A
Maximum instantaneous current600A
Maximum internal loop resistance0.25mΩ
Protective plate size300*100*24mm
Finished weight1000g

4.2. Product Function Configuration

FunctionConfiguration
Active equalizing current2A
Bluetooth functionStandard option
NTC quantity1 built-in, 4 external
RS485Two channels are standard
CANStandard option
Display interfaceStandard option
Heating functionStandard option
Dry contact functionTwo channels are standard
Charging overvoltage, overcurrent protectionStandard option
Discharge undervoltage, overcurrent protectionStandard option
Short circuit protectionStandard option
Battery parallel current limiting functionStandard option
Maximum continuous current300A

4.3. Product Adaptation Guide

Product SpecificationBattery TypeNumber of Adaptive Battery Strings
JK-PB2A16S-30PTernary lithium battery7-16
Lithium iron battery8-16
Lithium titanate battery14-16

4.4. Product Dimensions

JIKONG V19 BMS board showing the inductor coil
Figure: BMS Board Top View. This image provides a clear view of the BMS board, including the inductor coil and main terminals.

The JIKONG-PB2A16S-30P series protection board has dimensions of 300mm x 100mm x 24mm.

JIKONG V19 BMS board showing the main chip area
Figure: BMS Main Chip Area. A close-up of the BMS board showing the main chip and surrounding components.
JIKONG V19 BMS board showing the communication ports
Figure: BMS Communication Ports. This image highlights the various communication ports available on the BMS board.

5. Setup and Installation

5.1. Interface Definition

The protection board features a standard interface board with LED indicators, a reset switch, DIP switches, dry contacts, and communication functions. These interfaces are crucial for monitoring and configuring the BMS.

JIKONG V19 BMS board showing connection terminals
Figure: BMS Connection Terminals. This image illustrates the various connection terminals on the BMS board, including P1, P2, P3, P4, P5, P6, P7, P8, P9, P10, P11, D1, P-, and B-.

The interface board includes:

  • LED Indicators: Assist in determining the current BMS working status and remaining battery power.
  • Reset Button: Used to reset the BMS in case of abnormal operation.
  • DIP Switches: For setting addresses when the BMS is used in parallel (supports 16 addresses from 0 to 15).
  • Dry Contacts: For controlling external devices like alarms and fans.
  • CAN & RS485-1: For communication between the BMS and an inverter.
  • RS485-2: For connecting battery packs in parallel and communicating with a host computer.

5.2. Wiring Diagram

The JK-PB2A16S-30P series protection board is compatible with 7-16 series lithium battery packs. The specific wiring method varies depending on the number of cells in your battery pack. Always ensure correct polarity and secure connections.

General Wiring Principles:

  1. Connect the balance cables to the battery cells in the correct order (B0, B1, B2... up to B16).
  2. Connect the main positive (BAT+) and negative (BAT-) terminals of the battery pack to the corresponding terminals on the BMS.
  3. Connect the load/inverter to the P+ and P- terminals of the BMS.
  4. Connect the interface board to the BMS via the designated connector.
  5. If using the optional LCD display, connect it to the display interface.
  6. For parallel operation, connect the RS485-2 ports between BMS units using RJ45 Ethernet cables and connect the host BMS to the upper computer via a USB to RS485 serial port cable.

Refer to the detailed wiring diagrams in the official PDF manual for your specific battery configuration.

5.3. Device Activation

Before powering on the protection board, ensure all balance cables are correctly connected and that the P- and B- terminals are properly wired. Verify that the protection board is securely fixed to the battery pack. Incorrect connections can lead to abnormal operation or damage.

The BMS does not have a physical power-on switch. It is designed for charging activation. After completing the battery assembly, connect a charger (with a voltage 2V higher than the battery voltage) to activate the protection board. Alternatively, if you have the optional display and button, you can activate the BMS by inserting the cable into the display interface and pressing the button.

6. Operation

6.1. APP Installation

The mobile APP for the JIKONG BMS supports both Android and iOS operating systems. To install the APP, scan the QR code provided in the official manual. Android devices require a minimum of Android Version 7.

JIKONG Home Energy Storage BMS V19 Version, compatible with various inverter communication protocols
Figure: Mobile App Interface for Protocol Selection. This screenshot shows the mobile app interface for selecting UART protocols, indicating compatibility with various inverter brands.
Screenshot of the mobile app showing cell voltages and wire resistance
Figure: Mobile App Real-time Data. A screenshot of the mobile app displaying real-time cell voltages, wire resistance, and other battery parameters.

6.2. Parameter Settings

All operational parameters of the BMS can be configured via the mobile APP or the host computer software. This includes setting battery type, cell count, capacity, equalization differential pressure, voltage calibration, and current calibration.

Supported CAN Protocols table and a screenshot of the host computer interface for settings
Figure: Host Computer Interface for Parameter Settings. This image shows the host computer software interface for configuring various BMS parameters and a table of supported CAN protocols.
JIKONG Home Energy Storage BMS V19 Version, showing adjustable protection values via host computer interface
Figure: Adjustable Protection Values. A screenshot of the host computer interface demonstrating how to freely adjust multiple protection values such as overcharge, overdischarge, and overcurrent.

6.3. Active Equalization

The BMS employs active equalization to transfer energy from high-voltage cells to low-voltage cells, ensuring battery consistency. Users can set the balance trigger pressure difference (mV) in the APP. When the voltage difference between any two battery strings exceeds this value, equalization automatically begins. The default balance current is 2A. It is recommended that the balance current does not exceed 0.2C of the battery capacity. The balancing function can be turned off via the APP if not required.6.4. Display Interface

The protection board has a reserved display interface, allowing users to connect an optional JIKONG display for convenient viewing of battery information. This display provides real-time data such as voltage, current, capacity, and temperature.

6.5. Heating Function

The BMS includes a heating function to prevent battery performance degradation in low-temperature conditions. It uses a resistance heater or heating film to warm the battery. The designed heating current is 10A. Users can control this function via the APP. It is recommended to install a normally closed temperature switch (45°C to 65°C) in series with the heating circuit as a secondary protection against thermal runaway.6.6. Dry Contact Function

The BMS is equipped with two dry contacts for controlling external devices like alarms and fans. When the BMS detects over-temperature, overcharge, or over-discharge, these contacts can trigger an alarm or activate a cooling fan. Users can configure up to two trigger conditions in the APP.

6.7. Communication Function

The BMS supports CAN and RS485 communication. The default CAN communication rate is 250K. Users can select the appropriate protocol in the APP based on their inverter brand and specifications. There are two RS485 communication interfaces: RS485-1 for inverter communication and RS485-2 for parallel battery pack connections and host computer communication. The default baud rate for RS485 is 115200. The BMS address for parallel operation can be set using DIP switches (0-15).

6.8. Parallel Function

The parallel function allows multiple BMS units to be monitored simultaneously by a host computer via the RS485 bus. This requires a USB to RS485 serial port cable and the JIKONG host computer software. Up to 16 BMS units are supported, with address 0 designated as the host and addresses 1-15 as slaves. Addresses are set using the DIP switches on the interface board.

7. Protection Functions

The JIKONG V19 BMS provides comprehensive protection for your battery system. All protection parameters can be adjusted via the APP or host computer software.

7.1. Charge Overvoltage Protection and Recovery

The BMS protects against overcharging by monitoring individual cell voltages. If any cell's voltage exceeds the set overcharge protection voltage during charging, the BMS will stop charging. Charging resumes when all cell voltages drop below the overcharge recovery voltage.

7.2. Discharge Undervoltage Protection and Recovery

To prevent over-discharging, the BMS monitors individual cell voltages during discharge. If any cell's voltage falls below the set undervoltage protection voltage, the BMS will stop discharging. Discharge resumes when all cell voltages rise above the undervoltage recovery voltage. If any cell voltage drops below the automatic shutdown voltage, the BMS will shut down completely.

7.3. Charge Overcurrent Protection and Recovery

The BMS protects against excessive charging current. If the charging current exceeds the set continuous charging current for a specified delay time, the BMS will stop charging. Charging resumes after the overcurrent release time has passed.

7.4. Discharge Overcurrent Protection and Recovery

Similar to charge overcurrent protection, the BMS protects against excessive discharge current. If the discharge current exceeds the set continuous discharge current for a specified delay time, the BMS will stop discharging. Discharging resumes after the overcurrent release time has passed.

7.5. Overtemperature Protection and Recovery

The BMS monitors battery temperature during both charging and discharging. If the temperature exceeds the set over-temperature protection value, the BMS will stop the respective operation (charging or discharging). Operation resumes when the temperature falls below the recovery value.

7.6. Low Temperature Protection and Recovery

To prevent damage from charging in cold conditions, the BMS monitors battery temperature. If the temperature falls below the set low-temperature protection value, the BMS will stop charging. Charging resumes when the temperature rises above the recovery value. For extremely cold environments, using the heating function is recommended.

7.7. Short Circuit Protection and Recovery

The BMS includes short circuit protection. While the trigger current is not user-adjustable, users can set the short circuit protection delay (µs) and recovery time (S) in the APP. If a short circuit is detected, the BMS will immediately cut off the circuit. Recovery occurs after the set recovery time. If short circuits occur during initial connection, increasing the delay time may resolve issues caused by high peak currents from chargers or capacitive loads.

7.8. Emergency Switch

The emergency switch function provides a temporary override for critical situations. If issues like over-temperature, over-discharge, over-charge, or cell drop occur during normal use, activating the emergency switch in the APP's BMS control page will enable both charging and discharging for 30 minutes. This provides a window for emergency use, even if a single cell reaches the automatic shutdown voltage, preventing critical failures in situations like roadside breakdowns.

7.9. Intelligent Sleep

The intelligent sleep function allows the BMS to enter a low-power standby mode if the charging and discharging current is less than 1A for 26 consecutive hours. This reduces the BMS's own energy consumption. The BMS can be reactivated by pressing a button (if available) or by connecting a charger.

7.10. Charge Current Limiting Function

The BMS features a charge current limiting function. Users can set the continuous charging current (A), overcurrent delay (S), and overcurrent release time (S) in the APP. If the battery is overcharged, the current limiting function activates, maintaining the charging current at approximately 10A to protect the battery.

8. Troubleshooting

8.1. Common Issues and Solutions

  • BMS not responding to control functions via APP (e.g., charge/discharge on/off): This might be a firmware compatibility issue. Some users reported success by downgrading the BMS firmware to an earlier stable version (e.g., 19.10 if currently on 19.14).
  • BMS not working after initial connection (Bat+ and B- connected, Start button pressed): Ensure proper device activation. The BMS typically activates by connecting a charger with a voltage 2V higher than the battery voltage. If using an optional display with a button, ensure the cable is correctly inserted and the button is pressed. Double-check all wiring, especially balance cables and main power connections.
  • Inaccurate SOC display: Some users have noted that the SOC display might have calculation issues. While the BMS offers high-spec active balancing, the SOC reading might not always be perfectly accurate. Monitor individual cell voltages for a more reliable indication of battery state.
  • RS485 communication issues with inverter: While the BMS supports RS485 communication, some users have experienced stability issues when communicating with certain inverters. If encountering problems, verify the selected protocol in the APP matches your inverter's specifications.
  • Short circuit protection triggering unexpectedly: If this occurs during initial connection of a charger or load, it might be due to high peak currents. Try increasing the short circuit protection delay (us) in the APP settings. Ensure external wiring is free of actual short circuits.

8.2. LED Indicators

The LED indicators on the interface board provide visual feedback on the BMS status:

StatusON/OFF IndicatorRUNALML1-L6 (Power LED)Description
Power OffOFF
Balance (Normal)ONFlickerOFFBased on battery display
Charging (Normal)ONFlickerOFFBased on battery display
Charging (Overcurrent, Overtemp, Overvoltage, Failure)ONFlickerFlickerBased on battery display
Discharge (Normal)ONFlickerOFFBased on battery display
Discharge (Overcurrent, Overtemp, Undervoltage, Failure)ONFlickerFlickerBased on battery display
Other Alarms (Password not changed, Short circuit, Temperature)ONFlickerFlickerBased on battery display

Power LED Description:

SOC RangeLED1LED2LED3LED4LED5
0%~9%OFFOFFOFFOFFOFF
10%~19%ONOFFOFFOFFOFF
20%~39%ONONOFFOFFOFF
40%~59%ONONONOFFOFF
60%~79%ONONONONOFF
80%~100%ONONONONON

9. User Tips

  • Firmware Management: If you experience issues with control functions via the mobile or Windows application (e.g., charge/discharge on/off not responding), consider downgrading the BMS firmware to a known stable version (e.g., 19.10 if you received 19.14).
  • SOC Display Accuracy: The State of Charge (SOC) display might sometimes have calculation discrepancies. For critical applications, rely on individual cell voltage readings for a more precise understanding of battery status.
  • Active Balancing Advantage: The JIKONG BMS is highly regarded for its high-spec active balancing at 1A or 2A, a feature not commonly found in many other BMS units. This significantly contributes to battery longevity and performance.
  • Inverter Communication: While RS485 communication with inverters is supported, some users have noted potential issues. Ensure your inverter's protocol is correctly selected in the BMS app. If stability problems persist, consider alternative monitoring methods if available.
  • Home Assistant Integration: The BMS has been successfully integrated with Home Assistant in combination with an ESP8266, offering advanced monitoring and control possibilities for tech-savvy users.

10. Frequently Asked Questions (FAQ)

Q: Is this truly the V19 version?
A: Yes, the product is the V19 version as described. Please refer to the product specifications and firmware version for confirmation.
Q: Why doesn't the BMS work after connecting Bat+ and B- and pressing the Start button?
A: The BMS typically requires activation. After connecting Bat+ and B-, you usually need to connect a charger with a voltage 2V higher than the battery voltage to activate the BMS. If you have an optional display with a button, ensure it's connected and the button is pressed for activation. Always double-check all wiring connections.
Q: What is the purpose of this device?
A: This device is a Battery Management System (BMS) designed for large-capacity series lithium battery packs. Its purpose is to monitor, protect, and optimize the performance and lifespan of your battery by managing voltage, current, temperature, and ensuring cell balance.

11. Warranty and Support

For warranty information and technical support, please refer to the official JIKONG website or contact your authorized dealer. Keep your purchase receipt as proof of purchase. Always ensure installation and operation are performed by qualified personnel to avoid voiding the warranty.

User Manual (PDF): A detailed user manual in PDF format is available for download. This document contains comprehensive instructions, wiring diagrams, and technical specifications. View User Manual (PDF)


Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.