1. Introduction
This manual provides comprehensive instructions for the Aideepen 5-in-1 Air Quality Monitor, a device designed to accurately detect and monitor various air quality parameters in real-time. It helps you understand the air quality in your environment by measuring Formaldehyde (HCHO), Total Volatile Organic Compounds (TVOC), Carbon Dioxide (CO2), Temperature, and Humidity.
The monitor features a large HD screen for easy readability and provides fast, accurate, and stable detection results, ensuring you are aware of potential air quality issues.

2. Features
- Highly Sensitive and Fast Sensor: Adopts a high-performance sensor for accurate measurements, with detection data accuracy up to 0.001, ensuring precise real-time monitoring results.
- Multi-parameter Real-time Detection: Simultaneously monitors Carbon Dioxide (CO2), Formaldehyde (HCHO), Volatile Organic Compounds (TVOC), Temperature, and Humidity for a comprehensive understanding of air quality.
- Intelligent Automatic Calibration: Built-in automatic calibration system allows for long-term use without manual adjustment, ensuring stable and reliable data.
- Sound and Light Alarm: Automatically triggers audible and visual alarms when air quality exceeds safety thresholds, prompting users to take timely action.
- Air Convection Constant Anti-interference: Unique design ensures 99.9% stability of test capability, effectively resisting external interference for continuous and reliable detection.
- Multi-functional and Ultra-accurate: Provides healthy air testing for a healthier life.
- Simple and Practical: User-friendly design for ease of use.

3. Package Contents
Upon opening the package, please ensure all the following items are present:
- 1 x Air Quality Monitor (Tester)
- 1 x Instruction Manual
- 1 x Type C Charging Cable
4. Setup
4.1 Charging the Device
The monitor is equipped with a 1200mAh rechargeable battery. Before first use, or when the battery indicator shows low power, connect the device to a 5V power source using the provided USB Type-C charging cable.
4.2 Initial Power On
Press and hold the power button for 3 seconds to turn the system on. The display will light up and begin showing readings.
5. Operating Instructions
5.1 Power On/Off
To power on the device, press and hold the power button for 3 seconds. To power off, press and hold the power button for 3 seconds again.
5.2 Sound and Display Settings
- Sound On/Off: Briefly press the power button to toggle the sound on or off.
- Temperature/Humidity Display: Double-click the power button to switch between different temperature and humidity display forms (e.g., Celsius/Fahrenheit).
5.3 Understanding Air Quality Readings
The monitor displays real-time values for CO2, HCHO, TVOC, Temperature, and Humidity. Below the main readings, four color indicators provide a quick visual assessment of air quality levels:
- Green: Excellent/Good air quality
- Yellow: Slightly polluted
- Orange: Moderately polluted
- Red: Heavily polluted
If any detected parameter exceeds its safety standard, the device will automatically trigger an audible and visual alarm.

6. Maintenance
6.1 Automatic Calibration
The device features an intelligent automatic calibration system. This means it will self-adjust over time to maintain accuracy, requiring no manual calibration for long-term use.
6.2 Cleaning and Storage
- Wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Avoid exposing the device to extreme temperatures, direct sunlight, or high humidity.
- Store the device in a cool, dry place when not in use.

7. Troubleshooting
7.1 Device Not Turning On
- Ensure the device is fully charged. Connect it to a 5V power source using the Type-C cable and allow it to charge for some time.
- Press and hold the power button for at least 3 seconds.
7.2 Inaccurate Readings
- The device has an automatic calibration system. Allow it some time to stabilize, especially after initial power-on or moving to a new environment.
- Ensure the air inlets are not obstructed.
- Avoid placing the device near strong air currents, heat sources, or direct sunlight, which can affect sensor performance.
7.3 Alarm Triggering Frequently
- Check the displayed readings. If they are consistently high, it indicates poor air quality in the environment. Consider ventilation or identifying the source of pollution.
- The alarm thresholds are preset based on safety standards.
8. Specifications
| Parameter | Value |
|---|---|
| Detection Parameters | HCHO, TVOC, CO2, Temperature, Humidity |
| Power Supply | 1200mAh rechargeable battery |
| Working Voltage | 5V |
| Charging Mode | USB Type-C interface |
| Product Size | 90mm x 70mm x 35mm (3.54in x 2.76in x 1.38in) |
| Battery Included | Yes |
| Is Smart Device | No |
| With LCD Screen | Yes |
| Gas Type | Multifunctional |
| DIY Supplies | Electrical |
| Origin | Mainland China |
| Certification | NONE |

9. Warranty and Support
For specific warranty information and customer support, please refer to the official product page or contact the seller directly. This manual serves as a guide for product usage and does not imply any specific warranty terms.
A PDF version of the user manual may also be available for download from the seller's website for more detailed information.