1. Safety Instructions

Thank you for purchasing our product. Please read this manual carefully before use. Please keep this manual properly after reading.

General Precautions

  • Caution: There may be a risk of death or serious injury.
  • Caution: There may be a risk of personal injury or property loss.
  • Do not input signals exceeding the measurement range of this product. Select the correct test position and range to avoid damage to the instrument or personal injury. "OL" will be shown on the display when out of range.
  • When the voltage to be measured exceeds 36V DC or 25V AC, the operator shall be careful to avoid electric shock.
  • Check the function position before measuring.
  • Disconnect the test leads from the circuit before changing the mode.
  • For your safety, please read this manual carefully before use. Please fully understand the instructions and use this product correctly.

Measurement Notices

  • Common Notice: Do not measure circuits that exceed the maximum input rated value 1000V. DC/AC high voltage circuits are very dangerous, please be careful to measure. Do not add AC/DC voltages that exceed the maximum rated value between the ground terminal and test terminal. Do not operate this product with wet hands. Do not use around explosive gas or in damp environments. Do NOT touch the input terminals when measuring. Do not use test leads with damaged coatings.
  • AC/DC Voltage Measurement: The measured voltage should not exceed the rated maximum test value.
  • AC/DC Current Measurement: The measured current should not exceed the rated maximum test value. Use the 10A Terminal and the appropriate mode for unknown currents. Do not input voltage in this measuring state.
  • Resistance Measurement: Before measuring, ensure all capacitors in the circuit are fully discharged. Do not input voltage in this measuring state.
  • Continuity Measurement: Do not measure continuity with a voltage circuit or wire. Do not input voltage in this measuring state.

2. Product Overview

This product is a multi-functional, auto-ranging digital multimeter with a 6000 counts LCD display.

Key Features

  • Measurement functions include AC/DC voltage, AC/DC current, resistance, diode test/continuity, NCV, frequency/duty cycle, capacitance.
  • Support True-RMS.
  • Support Auto Power Off.
  • Support temperature measurement.
  • Support data hold.
ZOYI ZT-120A Multimeter with Auto Range and Smart Features

Figure 2.1: ZOYI ZT-120A Multimeter highlighting Auto Range, Dual-Mode Smart Multimeter features including Voltage, Inductance, Resistance, Capacitance, Temperature, Frequency, Continuity with Beep, NCV, Diode, Auto Detection, Data Hold, and Auto Power Off.

ZOYI ZT-102 Multimeter with Auto Range Digital Multimeter Features

Figure 2.2: ZOYI ZT-102 Multimeter highlighting Auto Range Digital Multimeter features including Voltage, Current, Resistance, Frequency, Capacitance, Temperature, 6000 Counts, Continuity, and Diode.

Appearance and Components

The multimeter features an LCD display, a function dial, input terminals, and control buttons.

ZOYI ZT-98 Multimeter with 6000 Counts One-Touch Data Hold

Figure 2.3: ZOYI ZT-98 Multimeter with 6000 Counts One-Touch Data Hold feature. Press the HOLD button lightly to freeze the reading.

3. Setup

Battery Installation

The multimeter requires batteries for operation. If the low battery indicator () is shown on the display, replace the batteries immediately.

  1. Turn off the multimeter and remove the test leads.
  2. Loosen the screw on the battery door and remove the battery door.
  3. Replace the used batteries with new batteries of the same type, observing polarity.
  4. Place the battery door back and fasten the screws.

Test Lead Connection

Proper connection of test leads is crucial for accurate and safe measurements.

  • For most measurements (Voltage, Resistance, Diode, Continuity, Frequency, Temperature, Capacitance): Insert the black test lead into the COM terminal and the red test lead into the VΩHz-T-C/FmA terminal.
  • For current measurements (up to 10A): Insert the black test lead into the COM terminal and the red test lead into the 10A terminal.
  • For current measurements (mA): Insert the black test lead into the COM terminal and the red test lead into the VΩHz-T-C/FmA terminal.

4. Operating Instructions

General Measurement Steps

  1. Confirm the measurement content.
  2. Switch the function dial to the appropriate measurement mode.
  3. Connect the test leads to the circuit or component to be measured.
  4. Read the measurement on the LCD display.
  5. After measurement, remove test leads and turn off the multimeter.

Specific Measurement Modes

Refer to the official user manual PDF for detailed connection illustrations and usage notes for each mode: ZOYI Digital Multimeter User Manual (PDF)

  • Auto Mode (Voltage/Resistance/Continuity): Rotate dial to AUTO. The multimeter automatically recognizes the measurement type.
  • DC/AC Voltage Measurement: Rotate dial to V (DC) or V~ (AC). Use SEL/NCV to toggle between AC/DC.
  • DC/AC Current Measurement: Rotate dial to A (DC) or A~ (AC) or mA. Use SEL/NCV to toggle between AC/DC.
  • Resistance Measurement: Rotate dial to Ω. Ensure the circuit is de-energized and capacitors are discharged.
  • Continuity Test: Rotate dial to ))). A built-in beeper will sound if resistance is below 50Ω.
  • Diode Test: Rotate dial to . Connect the red probe to the anode and black probe to the cathode.
  • Capacitance Measurement: Rotate dial to . Ensure capacitors are discharged before testing.
  • Frequency/Duty Cycle: Rotate dial to Hz/%.
  • NCV (Non-Contact Voltage) Function: Press and hold the SEL/NCV button to enter NCV mode. Move the multimeter near an AC voltage source; the beeper will sound and LED will flash.
  • Data Hold/REL: Press the HOLD/REL button briefly to freeze the current reading. Press and hold to enter Relative Measurement mode (REL).

Auto Power Off

To conserve battery life, the multimeter will automatically power off after approximately 15 minutes of inactivity. To disable this feature, press and hold the SEL/NCV button while turning on the multimeter. It will be cancelled after five beeps.

Product Demonstration Video

Video 4.1: A demonstration of the ZOYI ZT102A Digital Multimeter's various functions, including resistance, voltage, and current measurements.

5. Maintenance

Battery Replacement

Refer to Section 3.1 for detailed instructions on battery replacement.

Fuse Replacement

If current measurement is not possible, the fuse may be blown. Replace with the required rated fuse (F2 600mA/250V, F1 10A/250V).

  1. Remove the battery cover and batteries.
  2. Use a screwdriver to remove the two screws on the back cover and carefully open the casing.
  3. Replace the blown fuse with a new one of the correct rating.
  4. Reassemble the back cover and battery cover, tightening all screws.

Cleaning the Product

Wipe the product with a damp cloth and mild detergent. Do not use abrasives or solvents. Dirt or moisture in the terminals can affect readings. Remove input signals before cleaning.

Calibration

Calibration is regularly performed at a calibration laboratory to ensure accurate measurements. The recommended calibration period is once a year. Consult your dealer for calibration cost and delivery time.

Storage Method

Please turn off the power after use. If not used for a long time, remove the battery to prevent leakage and damage.

6. Troubleshooting

  • "OL" Display: Indicates that the measurement is out of range. Select a higher range or ensure the input is within the meter's capabilities.
  • Unstable Readings: May be caused by noise-generating devices nearby or large temperature differences. Try to move away from such sources.
  • Incorrect Current Measurement: Check if the fuse is blown. Refer to Section 5.2 for fuse replacement.
  • Irregular Display without Test Leads Connected: This is normal due to high input sensitivity and not a fault. Readings will stabilize once connected to a circuit.
  • No Display/Meter Not Turning On: Check battery installation and battery charge. Replace batteries if necessary.

7. Specifications

General Specifications

ParameterSpecification
Display (LCD)6000 counts
RangingAuto
MaterialABS/PVC
Update Rate3 times/second
Low Battery IndicationYes
Product Weight114g (batteries not included)
Product Dimension130x65x32mm
Operating Temperature0 - 40 °C
Operating Humidity<75%
Storage Temperature-20 - 60 °C
Storage Humidity<80%

Electrical Specifications

FunctionRangeResolutionAccuracyMax
DC Voltage (V)600mV - 1000V0.01mV - 1V±(0.5%+3)1000V
60mV - 600mV0.01mV - 0.1mV±(0.5%+3)600mV
AC Voltage (V)600mV - 750V0.01mV - 1V±(1.0%+3)750V
60mV - 600mV0.01mV - 0.1mV±(1.0%+3)600mV
DC Current (A)60mA - 10A0.01mA - 0.01A±(1.2%+3)10A
AC Current (A)60mA - 10A0.01mA - 0.01A±(1.5%+3)10A
Resistance (Ω)600Ω - 60MΩ0.1Ω - 0.01MΩ±(0.5%+3) - ±(1.5%+3)60MΩ
Capacitance (F)9.999nF - 9.999mF0.001nF - 0.001mF±(5.0%+20) - ±(5.0%+5)9.999mF
Frequency (Hz)99.99Hz - 9.999MHz0.01Hz - 0.001MHz±(0.1%+2)9.999MHz
Duty Cycle (%)1% - 99%0.1%±(0.1%+2)
Temperature (°C/°F)-20°C to 1000°C / -4°F to 1832°F1°C / 1°F±(2.5%+5)1000°C / 1832°F
DiodeYes
ContinuityYes

8. Warranty and Support

Limited Warranty and Limitation of Liability

Customers enjoy a one-year warranty from the date of purchase.

This warranty does not cover fuses, disposable batteries, damage from misuse, accident, neglect, alteration, contamination, or abnormal conditions of operation or handling, including failures caused by use outside of the product's specifications, or normal wear and tear of mechanical components.

All rights reserved. Specifications are subject to change without notice.

Additional Support

For further assistance, troubleshooting, or warranty claims, please contact the seller or manufacturer directly.

9. User Tips

  • Always double-check your test lead connections and function dial setting before taking any measurement to prevent damage to the meter or the circuit.
  • When measuring resistance or capacitance, ensure the circuit is de-energized and all capacitors are fully discharged to avoid inaccurate readings or damage.
  • For prolonged storage, always remove the batteries to prevent leakage and potential damage to the multimeter.