SZYTF MQ-135

Contents

MQ-135 Air Quality Sensor Module

User Instruction Manual

1. Product Overview

The MQ-135 Air Quality Sensor Module utilizes a sensitive material, tin oxide (SnO2), which has low conductivity in clean air. In the presence of polluting gases, the sensor's conductivity increases proportionally to the gas concentration. This change in conductivity is then converted into an output signal.

The MQ-135 sensor is highly sensitive to ammonia, sulfide, benzene vapor, and smoke, making it ideal for monitoring various harmful gases. It is a cost-effective solution suitable for a wide range of applications.

Applications:

  • Home and factory gas leakage monitoring devices.
  • Detection of liquefied petroleum gas (LPG), butane, propane, methane, and smoke.

2. Features

  • High-quality dual-panel design.
  • Equipped with a power indicator LED.
  • Provides both a digital TTL signal output (DO) and an analog output (AO).
  • The TTL output valid signal is low (low-level signal), allowing direct connection to microcontrollers or relay modules.
  • Analog output voltage increases with higher gas concentration.
  • Four screw holes for easy mounting and positioning.
  • Designed for long life and reliable stability.
  • Exhibits rapid response and recovery characteristics.

3. Setup and Wiring

Before operation, ensure proper wiring and initial warm-up.

Wiring Diagram:

Top view of MQ-135 sensor module showing the gas sensing element and pin headers.
Figure 1: MQ-135 Sensor Module (Top View)
Bottom view of MQ-135 sensor module showing the potentiometer, power LED, output LED, and pin labels.
Figure 2: MQ-135 Sensor Module (Bottom View with Pin Labels)

Pin Connections:

Pin Description
VCC Positive power supply (DC 5V)
GND Ground (Negative power supply)
DO Digital Output (TTL switching signal)
AO Analog Output

Initial Warm-up:

After the sensor is powered on, it requires approximately 20 seconds to warm up. During this period, the sensor stabilizes, and measured data will become accurate. It is normal for the sensor to generate heat due to its internal heating wire.

4. Operating Instructions

The MQ-135 module provides two types of output signals:

Digital Output (DO):

  • The DO pin provides a TTL-level digital signal (0V or 5V).
  • This output goes LOW when the detected gas concentration exceeds a preset threshold.
  • The threshold can be adjusted using the onboard potentiometer (blue square component on the bottom side).
  • This output is suitable for simple gas presence detection or triggering alarms.

Analog Output (AO):

  • The AO pin provides an analog voltage signal that varies with the concentration of detected gases.
  • A higher gas concentration results in a higher analog output voltage.
  • This output is suitable for more precise measurements of gas concentration, requiring an Analog-to-Digital Converter (ADC) on a microcontroller.

5. Maintenance

  • Keep the sensor clean and free from dust or debris, especially the sensing element (metal mesh cap).
  • Avoid exposing the sensor to extreme temperatures or humidity outside its operating range.
  • Handle the module with care to prevent physical damage to components or solder joints.
  • Do not immerse the sensor in liquids.

6. Troubleshooting

No Output or Incorrect Readings:

  • Check Wiring: Ensure all VCC, GND, DO, and AO connections are secure and correctly wired.
  • Power Supply: Verify that the module is receiving a stable 5V DC power supply.
  • Warm-up Time: Allow at least 20 seconds for the sensor to warm up after power-on before expecting stable readings.
  • Potentiometer Adjustment: For digital output (DO), adjust the onboard potentiometer to set the detection threshold.

Sensor is Hot:

  • This is normal operation. The sensor contains an internal heating element necessary for its function.

Sensor Not Responding to Gas:

  • Ensure the gas source is present and at a detectable concentration.
  • Verify the sensor is correctly powered and warmed up.
  • For DO, try adjusting the potentiometer to a more sensitive setting.

7. Specifications

Parameter Value
Sensor Type Gas Sensor
Sensing Material Tin Oxide (SnO2)
Input Voltage DC 5V
Power Consumption (Current) 150mA
Digital Output (DO) TTL digital 0 and 1 (0.1V and 5V)
Analog Output (AO) 0.1V - 0.3V (relative to pollution), max 4V
Output Type Analog Sensor
Material Metal
Use Gas Sensor

8. User Tips

  • Calibration: For precise measurements, it is recommended to calibrate the analog output (AO) against known gas concentrations.
  • Threshold Adjustment: When using the digital output (DO), carefully adjust the potentiometer to set the detection threshold appropriate for your application.
  • Data Interpretation: The analog output provides a continuous range of values, offering more detailed information about gas concentration compared to the binary digital output.
  • Environmental Factors: Be aware that temperature and humidity can affect sensor readings. Consider environmental compensation if high accuracy is required.

9. Warranty and Support

For any technical support, warranty claims, or further inquiries regarding your MQ-135 Air Quality Sensor Module, please contact the seller or manufacturer directly. Refer to your purchase documentation for specific contact details.

A detailed user manual in PDF format may also be available from the seller for additional information.

© 2023 SZYTF. All rights reserved.