GEYA GPS8-10

Contents

GEYA Voltage/Current Protector Switch GPS8-10 Instruction Manual

Model: GPS8-10 | Brand: GEYA

1. Introduction

The GEYA GPS8-10 is a smart bi-directional energy power kWh digital meter and protector switch designed for household equipment. It provides comprehensive protection against overvoltage, undervoltage, overcurrent, and leakage, while also displaying real-time frequency, power factor, power, and electricity consumption. Certain models (GPS8-10D) support WiFi connectivity for remote monitoring and control via a mobile application.

GEYA GPS8-10 Voltage/Current Protector Switch

Figure 1: GEYA GPS8-10 Device Overview

2. Key Features

  • Four-fold Intelligent Protection: Offers comprehensive safety with overvoltage, undervoltage, overcurrent, and leakage protection for household appliances.
  • Self-Recovery of Faults: Automatically resets and powers on after voltage, current, or leakage faults are cleared, ensuring continuous operation.
  • Visible Electricity Consumption: A large color screen displays real-time voltage, current, power, and electricity consumption parameters for clear monitoring.
  • Freely Adjustable Parameters: Protection thresholds and delay times can be flexibly adjusted to suit various application needs.
  • Industrial Level Installation: Designed for stable and reliable DIN rail mounting.
  • Special Metering Chips: Utilizes advanced chips for accurate detection of voltage, current, electricity consumption, and power.
  • Double Bus Wiring: Features a robust double bus wiring design for enhanced stability.
  • WiFi Connectivity (GPS8-10D models): Allows mobile phones to remotely check power status and control the device via the Tuya app.
WIFI V/A Protection Meter Features

Figure 2: WIFI V/A Protection Meter Overview

3. Technical Specifications

ParameterSpecification
FunctionOver voltage, under voltage and over current
Rated supply voltageAC220V(L-N)
Rated supply frequency45~65Hz
Operation voltage range80V~400V(L-N)
Rated operational current32A,40A,50A,63A,80A (AC1)
BurdenAC max.3VA
Over voltage operation valueOFF,230V~300V
Under voltage operation value140V~210V,OFF
Over/under voltage action delay0.1s~10s
Over current operation value1-32A,40A,50A,63A,80A
Over current action delay2s~600s
Leakage current valueOFF,10mA-400mA
Leakage reclosing countOFF,1-20,ON
Power-up delay2s~600s
Reset time2s~900s
Measurement error≤1%
Electrical life(AC1)1×104
Mechanical life1×106
Operating temperature-20℃ ~ +60℃
Storage temperature-35℃ ~ +75℃
Mounting/DIN railDin rail EN/IEC 60715
Protection degreeIP40 for front panel/IP20 terminals
Operating positionany
Overvoltage categoryIII.
Pollution degree2
Dimensions82×54×68mm
Weight205g
GEYA GPS8-10 Dimensions Diagram

Figure 3: Dimensions (mm)

4. Safety Information

  • This product does not have an isolation function.
  • Always disconnect the superior Miniature Circuit Breaker (MCB) during maintenance to prevent electric shock.
  • Installation must be performed by qualified electricians.
  • All electrical connections must comply with appropriate safety standards.

5. Installation

5.1 Wiring Diagram

The GPS8-10 is designed for DIN rail mounting. Ensure correct connection of live (L) and neutral (N) wires as shown in the diagram. The upper end serves as the incoming line, and the bottom end connects to the load.

GEYA GPS8-10 Wiring Diagram

Figure 4: Wiring Diagram (AC 220V)

5.2 Installation Video Guide

Video 1: GEYA GPS8-10 Usage and WiFi Setup Demonstration. This video illustrates the wiring process, manual operation, and steps for connecting the device to the Tuya app.

6. Operation

6.1 Panel Overview and Button Functions

GEYA GPS8-10 Panel Diagram

Figure 5: Panel Diagram and Button Functions

No.Description
1Press and hold the setting key (M) for 3 seconds to enter the setting interface. After modifying, press and hold for 3 seconds to save.
2WiFi Matching Key: Used to increase values when setting parameters. Long press for 5 seconds to configure the WiFi network.
3Manual Switch: Used to reduce values when setting parameters. After exiting settings, it can manually turn on/off the load. If automatic fault reset is off, this button can be used for manual reset.
4Current value display
5Electricity consumption display
6Power display
7Power factor display
8Frequency display
9Leakage current display
10Leakage fault indication
11Overcurrent fault indication
12Overvoltage fault indication
13Undervoltage fault indication
14ON/OFF status indication
15Voltage value display

6.2 Manual On/Off

Under normal operation, the load can be switched ON or OFF manually by pressing the power key (button 3) for 0.5 seconds.

6.3 Power-on and Reset Delay

During power-on or after a fault reset, the product will display a countdown according to the set delay time. It will enter the running state once the countdown finishes.

7. Parameter Settings

To enter the parameter setting interface, long press the 'M' key (button 1) for 3 seconds. Use the up/down keys (buttons 2 and 3) to increase or decrease values. A long press on these keys allows for quick adjustment. If no key is operated for 60 seconds, the device will automatically exit the setting mode. To manually exit and save settings, press the 'M' key for 3 seconds.

GEYA GPS8-10 Parameter Setting Flow Chart

Figure 6: Parameter Setting Flow Chart

7.1 Factory Settings

The device comes with predefined factory settings. To restore these settings:

  1. Ensure the device is powered off.
  2. Press and hold both the 'Up' (button 2) and 'Down' (button 3) keys simultaneously.
  3. While holding the keys, power on the device. This will restore the factory settings.
ParameterRangeStep valueFactory settings
Over voltage valueOFF,230V-300V1V275V
Over voltage recovery value225V-295V1V265V
Under voltage value140V-210V,OFF1V175V
Under voltage recovery value145V-215V1V180V
Voltage fault action time0.1s-10s0.1s0.5s
Over current valueOFF,1A-32/40/50/63A/80A0.1A32A/40/50/63A
Over current action delay2s-600s1s5s
Leakage currentOFF,10mA-400mA1mA30mA
Leakage reclosing countOFF,1-20,ON13
Power on delay time2s-600s1s5s
Reset time2s-900s1s30s
Fault resetON-OFFON

8. WiFi Configuration (GPS8-10D models only)

To connect your GPS8-10D device to your WiFi network and the Tuya Smart app:

  1. Ensure your mobile phone is connected to a 2.4GHz WiFi network. The device does not support 5GHz networks.
  2. Scan the QR code located on the side of the product to download and install the Tuya Smart app.
  3. On the GPS8-10D device, long press the WiFi matching key (button 2) for 5 seconds to enter the WiFi configuration state. The WiFi indicator on the device will flash.
  4. Open the Tuya Smart app on your phone and follow the prompts to add a new device.
  5. When the WiFi indicator is solid ON, it indicates a good WiFi signal. If it flashes, it's waiting for configuration. If it's OFF, WiFi cannot be connected.

NOTE: Please ensure that your WiFi network is 2.4G.

9. Protection Functions Diagram

The following diagrams illustrate the behavior of the protector under different fault conditions:

GEYA GPS8-10 Functions Diagram

Figure 7: Functions Diagram (Over/Under Voltage, Overcurrent, Leakage)

  • Overvoltage/Undervoltage Fault: When an overvoltage or undervoltage fault occurs, the protector will turn off. It will automatically turn back on after the voltage returns to normal and the set reset time (Tr) has elapsed.
  • Overcurrent Fault: If the current exceeds the set value and persists for the configured action delay (Tc), the protector will turn off and initiate a reset delay (Tr). It will turn on again after the delay.
  • Leakage Current Fault: If the circuit's leakage current exceeds the set value, the protector will turn off. The leakage protection function can be disabled in settings. The device will attempt to reclose based on the set reclosing count. If the count is exceeded, it will not reclose and the leakage current indicator will light up. Manual reset via the ON/OFF button is required. The reclosing count can be set to 'ON' for permanent reclosing activation.

Key to Timing Parameters:

  • Tp: Power-up delay (2-600s)
  • Tr: Reset delay time (2-900s)
  • Tu: Over/under voltage fault action time (0.1-10s)
  • Tc: Overcurrent fault action time (2-600s)

10. User Tips

  • The GPS8-10 device displays both current and voltage, and can also show active power and total electricity consumption, providing comprehensive monitoring of your electrical usage.
  • For models with WiFi functionality (GPS8-10D), utilize the Tuya Smart app for convenient remote control and monitoring of your device's status and energy data.
  • Always ensure your WiFi network is set to 2.4GHz when configuring the device for smart connectivity.

11. Maintenance

Regularly inspect the device for any signs of damage or loose connections. Ensure the installation area is clean and free from dust or moisture. For any internal maintenance or repairs, always consult a qualified electrician and ensure power is completely disconnected from the circuit by switching off the main circuit breaker.

12. Troubleshooting

  • Device not powering on: Check the main power supply and ensure all wiring connections are secure and correct. Verify that the superior MCB is switched ON.
  • WiFi connection issues:
    • Ensure your router is broadcasting a 2.4GHz WiFi signal. The device does not support 5GHz.
    • Confirm your phone is connected to the same 2.4GHz network during setup.
    • Long press the WiFi matching key (button 2) for 5 seconds until the WiFi indicator flashes, indicating pairing mode.
    • If the WiFi indicator is OFF, it means WiFi cannot be connected. Try restarting your router or moving the device closer to the router.
  • Device trips frequently: Review your parameter settings for overvoltage, undervoltage, overcurrent, and leakage. Adjust the thresholds and action delays if necessary, ensuring they match your load requirements and local electrical standards.
  • Display is blank or erratic: Check power supply. If the issue persists, contact customer support.
  • Cannot reset after a fault: If automatic fault reset is turned off, use the manual switch (button 3) to reset the device. For leakage faults, if the reclosing count is exceeded, manual reset is required.

13. Warranty and Support

For warranty claims, technical support, or service inquiries, please contact GEYA Electrical Co., Ltd. directly. Refer to the contact information provided on the product packaging or the official GEYA website.

GEYA Electrical Co., Ltd.
Add: Wenzhou Bridge Industrial Zone, Beibaixiang Town, Yueqing, Zhejiang, China 325603
E-mail: sale@cngeya.com
Web: www.geya.net

A user manual in PDF format is available for download: View User Manual (PDF)

14. Disposal of Electrical Waste

All electrical waste should be disposed of in compliance with current WEEE (Waste Electrical and Electronic Equipment) regulations. Do not dispose of this product with general household waste. Please locate appropriate collection facilities or recycling centers in your area for environmentally sound disposal.

© 2024 GEYA Electrical Co., Ltd. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.