1. Introduction
The GEYA GPS8-10 is a smart bi-directional energy power kWh digital meter and protector switch designed for household equipment. It provides comprehensive protection against overvoltage, undervoltage, overcurrent, and leakage, while also displaying real-time frequency, power factor, power, and electricity consumption. Certain models (GPS8-10D) support WiFi connectivity for remote monitoring and control via a mobile application.

Figure 1: GEYA GPS8-10 Device Overview
2. Key Features
- Four-fold Intelligent Protection: Offers comprehensive safety with overvoltage, undervoltage, overcurrent, and leakage protection for household appliances.
- Self-Recovery of Faults: Automatically resets and powers on after voltage, current, or leakage faults are cleared, ensuring continuous operation.
- Visible Electricity Consumption: A large color screen displays real-time voltage, current, power, and electricity consumption parameters for clear monitoring.
- Freely Adjustable Parameters: Protection thresholds and delay times can be flexibly adjusted to suit various application needs.
- Industrial Level Installation: Designed for stable and reliable DIN rail mounting.
- Special Metering Chips: Utilizes advanced chips for accurate detection of voltage, current, electricity consumption, and power.
- Double Bus Wiring: Features a robust double bus wiring design for enhanced stability.
- WiFi Connectivity (GPS8-10D models): Allows mobile phones to remotely check power status and control the device via the Tuya app.

Figure 2: WIFI V/A Protection Meter Overview
3. Technical Specifications
| Parameter | Specification |
|---|---|
| Function | Over voltage, under voltage and over current |
| Rated supply voltage | AC220V(L-N) |
| Rated supply frequency | 45~65Hz |
| Operation voltage range | 80V~400V(L-N) |
| Rated operational current | 32A,40A,50A,63A,80A (AC1) |
| Burden | AC max.3VA |
| Over voltage operation value | OFF,230V~300V |
| Under voltage operation value | 140V~210V,OFF |
| Over/under voltage action delay | 0.1s~10s |
| Over current operation value | 1-32A,40A,50A,63A,80A |
| Over current action delay | 2s~600s |
| Leakage current value | OFF,10mA-400mA |
| Leakage reclosing count | OFF,1-20,ON |
| Power-up delay | 2s~600s |
| Reset time | 2s~900s |
| Measurement error | ≤1% |
| Electrical life(AC1) | 1×104 |
| Mechanical life | 1×106 |
| Operating temperature | -20℃ ~ +60℃ |
| Storage temperature | -35℃ ~ +75℃ |
| Mounting/DIN rail | Din rail EN/IEC 60715 |
| Protection degree | IP40 for front panel/IP20 terminals |
| Operating position | any |
| Overvoltage category | III. |
| Pollution degree | 2 |
| Dimensions | 82×54×68mm |
| Weight | 205g |

Figure 3: Dimensions (mm)
4. Safety Information
- This product does not have an isolation function.
- Always disconnect the superior Miniature Circuit Breaker (MCB) during maintenance to prevent electric shock.
- Installation must be performed by qualified electricians.
- All electrical connections must comply with appropriate safety standards.
5. Installation
5.1 Wiring Diagram
The GPS8-10 is designed for DIN rail mounting. Ensure correct connection of live (L) and neutral (N) wires as shown in the diagram. The upper end serves as the incoming line, and the bottom end connects to the load.

Figure 4: Wiring Diagram (AC 220V)
5.2 Installation Video Guide
Video 1: GEYA GPS8-10 Usage and WiFi Setup Demonstration. This video illustrates the wiring process, manual operation, and steps for connecting the device to the Tuya app.
6. Operation
6.1 Panel Overview and Button Functions

Figure 5: Panel Diagram and Button Functions
| No. | Description |
|---|---|
| 1 | Press and hold the setting key (M) for 3 seconds to enter the setting interface. After modifying, press and hold for 3 seconds to save. |
| 2 | WiFi Matching Key: Used to increase values when setting parameters. Long press for 5 seconds to configure the WiFi network. |
| 3 | Manual Switch: Used to reduce values when setting parameters. After exiting settings, it can manually turn on/off the load. If automatic fault reset is off, this button can be used for manual reset. |
| 4 | Current value display |
| 5 | Electricity consumption display |
| 6 | Power display |
| 7 | Power factor display |
| 8 | Frequency display |
| 9 | Leakage current display |
| 10 | Leakage fault indication |
| 11 | Overcurrent fault indication |
| 12 | Overvoltage fault indication |
| 13 | Undervoltage fault indication |
| 14 | ON/OFF status indication |
| 15 | Voltage value display |
6.2 Manual On/Off
Under normal operation, the load can be switched ON or OFF manually by pressing the power key (button 3) for 0.5 seconds.
6.3 Power-on and Reset Delay
During power-on or after a fault reset, the product will display a countdown according to the set delay time. It will enter the running state once the countdown finishes.
7. Parameter Settings
To enter the parameter setting interface, long press the 'M' key (button 1) for 3 seconds. Use the up/down keys (buttons 2 and 3) to increase or decrease values. A long press on these keys allows for quick adjustment. If no key is operated for 60 seconds, the device will automatically exit the setting mode. To manually exit and save settings, press the 'M' key for 3 seconds.

Figure 6: Parameter Setting Flow Chart
7.1 Factory Settings
The device comes with predefined factory settings. To restore these settings:
- Ensure the device is powered off.
- Press and hold both the 'Up' (button 2) and 'Down' (button 3) keys simultaneously.
- While holding the keys, power on the device. This will restore the factory settings.
| Parameter | Range | Step value | Factory settings |
|---|---|---|---|
| Over voltage value | OFF,230V-300V | 1V | 275V |
| Over voltage recovery value | 225V-295V | 1V | 265V |
| Under voltage value | 140V-210V,OFF | 1V | 175V |
| Under voltage recovery value | 145V-215V | 1V | 180V |
| Voltage fault action time | 0.1s-10s | 0.1s | 0.5s |
| Over current value | OFF,1A-32/40/50/63A/80A | 0.1A | 32A/40/50/63A |
| Over current action delay | 2s-600s | 1s | 5s |
| Leakage current | OFF,10mA-400mA | 1mA | 30mA |
| Leakage reclosing count | OFF,1-20,ON | 1 | 3 |
| Power on delay time | 2s-600s | 1s | 5s |
| Reset time | 2s-900s | 1s | 30s |
| Fault reset | ON-OFF | ON |
8. WiFi Configuration (GPS8-10D models only)
To connect your GPS8-10D device to your WiFi network and the Tuya Smart app:
- Ensure your mobile phone is connected to a 2.4GHz WiFi network. The device does not support 5GHz networks.
- Scan the QR code located on the side of the product to download and install the Tuya Smart app.
- On the GPS8-10D device, long press the WiFi matching key (button 2) for 5 seconds to enter the WiFi configuration state. The WiFi indicator on the device will flash.
- Open the Tuya Smart app on your phone and follow the prompts to add a new device.
- When the WiFi indicator is solid ON, it indicates a good WiFi signal. If it flashes, it's waiting for configuration. If it's OFF, WiFi cannot be connected.
NOTE: Please ensure that your WiFi network is 2.4G.
9. Protection Functions Diagram
The following diagrams illustrate the behavior of the protector under different fault conditions:

Figure 7: Functions Diagram (Over/Under Voltage, Overcurrent, Leakage)
- Overvoltage/Undervoltage Fault: When an overvoltage or undervoltage fault occurs, the protector will turn off. It will automatically turn back on after the voltage returns to normal and the set reset time (Tr) has elapsed.
- Overcurrent Fault: If the current exceeds the set value and persists for the configured action delay (Tc), the protector will turn off and initiate a reset delay (Tr). It will turn on again after the delay.
- Leakage Current Fault: If the circuit's leakage current exceeds the set value, the protector will turn off. The leakage protection function can be disabled in settings. The device will attempt to reclose based on the set reclosing count. If the count is exceeded, it will not reclose and the leakage current indicator will light up. Manual reset via the ON/OFF button is required. The reclosing count can be set to 'ON' for permanent reclosing activation.
Key to Timing Parameters:
- Tp: Power-up delay (2-600s)
- Tr: Reset delay time (2-900s)
- Tu: Over/under voltage fault action time (0.1-10s)
- Tc: Overcurrent fault action time (2-600s)
10. User Tips
- The GPS8-10 device displays both current and voltage, and can also show active power and total electricity consumption, providing comprehensive monitoring of your electrical usage.
- For models with WiFi functionality (GPS8-10D), utilize the Tuya Smart app for convenient remote control and monitoring of your device's status and energy data.
- Always ensure your WiFi network is set to 2.4GHz when configuring the device for smart connectivity.
11. Maintenance
Regularly inspect the device for any signs of damage or loose connections. Ensure the installation area is clean and free from dust or moisture. For any internal maintenance or repairs, always consult a qualified electrician and ensure power is completely disconnected from the circuit by switching off the main circuit breaker.
12. Troubleshooting
- Device not powering on: Check the main power supply and ensure all wiring connections are secure and correct. Verify that the superior MCB is switched ON.
- WiFi connection issues:
- Ensure your router is broadcasting a 2.4GHz WiFi signal. The device does not support 5GHz.
- Confirm your phone is connected to the same 2.4GHz network during setup.
- Long press the WiFi matching key (button 2) for 5 seconds until the WiFi indicator flashes, indicating pairing mode.
- If the WiFi indicator is OFF, it means WiFi cannot be connected. Try restarting your router or moving the device closer to the router.
- Device trips frequently: Review your parameter settings for overvoltage, undervoltage, overcurrent, and leakage. Adjust the thresholds and action delays if necessary, ensuring they match your load requirements and local electrical standards.
- Display is blank or erratic: Check power supply. If the issue persists, contact customer support.
- Cannot reset after a fault: If automatic fault reset is turned off, use the manual switch (button 3) to reset the device. For leakage faults, if the reclosing count is exceeded, manual reset is required.
13. Warranty and Support
For warranty claims, technical support, or service inquiries, please contact GEYA Electrical Co., Ltd. directly. Refer to the contact information provided on the product packaging or the official GEYA website.
GEYA Electrical Co., Ltd.
Add: Wenzhou Bridge Industrial Zone, Beibaixiang Town, Yueqing, Zhejiang, China 325603
E-mail: sale@cngeya.com
Web: www.geya.net
A user manual in PDF format is available for download: View User Manual (PDF)
14. Disposal of Electrical Waste
All electrical waste should be disposed of in compliance with current WEEE (Waste Electrical and Electronic Equipment) regulations. Do not dispose of this product with general household waste. Please locate appropriate collection facilities or recycling centers in your area for environmentally sound disposal.