Hantek TO1152C TO1202C TO1252C TO1154C TO1204C

Contents

Hantek TO1000 Series Multi-function Full Touch Screen Tablet Digital Oscilloscope User Manual

Models: TO1152C, TO1202C, TO1252C, TO1154C, TO1204C

1. Introduction

The Hantek TO1000 series represents a new generation of multi-function full touch screen tablet digital oscilloscopes. Designed for portability and durability, these devices feature a thin, lightweight body, a unique hanging design for hands-free operation, and robust anti-fall and shock resistance. The TO1000 series integrates multiple essential functions into one compact unit: an oscilloscope, multimeter, signal generator, and spectrum analyzer. Equipped with a large-capacity battery and fast-charging support, it ensures long-lasting performance for various testing applications.

2. Safety Information

Please read all safety instructions carefully before operating the device. Failure to follow these instructions may result in injury or damage to the product.

  • Do not expose the device to moisture, rain, or extreme temperatures.
  • Use only the provided or approved power adapter and charging cable.
  • Avoid dropping the device or subjecting it to strong impacts.
  • Do not attempt to disassemble or modify the device. Refer all servicing to qualified personnel.
  • Ensure proper ventilation when operating the device.
  • Always connect probes correctly and ensure they are rated for the voltage/current being measured.

3. Package Contents

Verify that all items listed below are included in your package:

  • Host Unit * 1
    Hantek TO1000 Series Host Unit

    The main Hantek TO1000 series device.

  • Oscilloscope Probe (One for two Channel Series and Two for four Channel Series)
    Oscilloscope Probe

    Probes for oscilloscope measurements.

  • Multimeter Probe * 1 (Only Standard Configuration of TO1000C/D Series)
    Multimeter Probe

    Probes specifically for multimeter functions.

  • Crocodile Clip (One for Two Channel Series and Two for four Channel Series, One More for the Model With Signal Source Function)
    Crocodile Clips

    Clips for secure connections during testing.

  • 18W Adapter * 1, Type-C Charging Cable * 1
    18W Adapter and Type-C Charging Cable

    Power adapter and USB Type-C cable for charging.

  • Instrument Package * 1
    Instrument Package/Case

    Protective carrying case for the device and accessories.

4. Product Features

The Hantek TO1000 series offers a comprehensive suite of features for various electrical testing needs:

  • Multi-touch Large Screen: Features an 800*480 resolution display with a user-friendly UI for intuitive interaction.
  • Digital Storage Oscilloscope: Standard 2 or 4 channels with bandwidths up to 250MHz, a sampling rate of 1GS/s, and 8M storage depth. Supports various triggers including edge, slope, pulse width, video, and timeout. Offers up to 42 measurement functions.
  • High-Precision Multimeter: Provides AC/DC voltage, current, resistance, capacitance, diode, and on-off measurements. Includes data recording, storage, trend graphs, and statistical analysis capabilities.
  • Arbitrary Function Signal Generator: Maximum output frequency of 25MHz, 12-bit high resolution, and 200MS/s high sampling rate. Built-in arbitrary waveforms, AM/FM modulation support, and switchable high/low resistance output.
  • FFT Spectrum Analyzer: Integrated for frequency domain analysis.
  • One-Key Waveform Storage: Convenient and quick saving of waveforms.
  • Unique Hanging Design: Features hanging feet for multi-angle adjustment, allowing for hands-free operation and enhanced durability against drops and shocks.
  • Long-Lasting Battery: Built-in 10000mAh removable lithium battery provides abundant power and extended battery life, with standby time up to half a year.
  • Fast Charging: Standard 18W charger with Type-C fast charging support, compatible with mobile phone charging equipment.

Official product overview video demonstrating key features and design.

Hantek TO1000 Series Multi-function Overview

Visual representation of the integrated multi-functions: Oscilloscope, DMM, AFG, File Browser, Settings, and Pictures.

Hantek TO1000 Series Oscilloscope Display

Example of the four-channel oscilloscope display showing multiple waveforms.

Hantek TO1000 Series Oscilloscope Trigger and Measurement

Detailed view of oscilloscope trigger settings and measurement functions.

Hantek TO1000 Series Signal Generator Interface

Interface for the arbitrary function signal generator, showing waveform selection and modulation options.

Hantek TO1000 Series Multimeter Data Recording

Multimeter display with data recording and trend graph capabilities.

Hantek TO1000 Series Hanging Design

The unique hanging design of the device, allowing for versatile placement.

Hantek TO1000 Series Kickstand in Use

The integrated kickstand for stable desktop use.

Hantek TO1000 Series Battery Compartment

Internal view showing the large capacity 18650 batteries for extended endurance.

Hantek TO1000 Series Type-C Fast Charging Port

The Type-C port supporting 9V2A fast charging.

5. Specifications

AttributeValue
Brand NameHantek
Model NumberHantek TO1152C TO1202C TO1252C TO1154C TO1204C
DIY SuppliesElectrical
OriginMainland China
CertificationCE
Band Width100-349MHz
Digital Channels4
Real Time Sampling Rate1GSa/S
Record Length8M
Max Waveform Capture Rate30,000wfm/s
Display Resolution640*480 Pixels
Display Size5.0 - 6.9 Inches
Battery IncludedYes
IS Battery DemountableNo
High-concerned ChemicalNone

Detailed Oscilloscope Specifications

ParameterTO1000 Series (1G Sampling)TO1112 Series (250M Sampling)
Horizontal Scale Range2ns/div~100s/div (1, 2, 5 sequence)2ns/div~100s/div (1, 2, 5 sequence)
Incremental Time Measurement Accuracy± (1 sampling interval +100ppm × reading +0.6ns)± (1 sampling interval +100ppm × reading +0.6ns)
Average Measurement Accuracy>16 times on average>16 times on average
Full Bandwidth Accuracy±(1 sampling interval +100ppm × reading +0.4ns)±(1 sampling interval +100ppm × reading +0.4ns)
Sampling Intervalseconds/grid ÷200seconds/grid ÷200
A/D Converter8-bit resolution, each channel sampled simultaneously8-bit resolution, each channel sampled simultaneously
Vertical Scale Range2mV/div~10V/div at input BNC10mV/div~10V/div at input BNC
Vertical Resolution8bit8bit
Vertical Sensitivity Range2mV/div~10V/div10mV/div~10V/div
Offset Range±1V (2mV/div~100mV/div)
±10V (200mV/div~1V/div)
±50V (2V/div~10V/div)
±1Vmax (100mV/div)
±10Vmax (1V/div)
±50Vmax (10V/div)
Dynamic Range±5div (8bit)±5div (8bit)
Optional Analog Bandwidth Limitation, Typical20MHz, Each channel is independently selectable20MHz, Each channel is independently selectable
DC Gain Accuracy±3% FullScale±3% FullScale
Isolation Between Channels40dB, DC to the maximum rated bandwidth of each model40dB, DC to the maximum rated bandwidth of each model

Note: Bandwidth reduced to 6MHz when using a 1X probe.

6. Setup

  1. Unpacking: Carefully remove all components from the packaging. Retain the packaging for future storage or transport.
  2. Initial Charge: Before first use, fully charge the device using the provided 18W adapter and Type-C charging cable. Connect the Type-C cable to the device's charging port and the adapter to a power outlet. The charging indicator will show the charging status.
    Hantek TO1000 Series Type-C Fast Charging Port

    Connect the Type-C cable for fast charging.

  3. Power On/Off: Press and hold the power button (usually located on the side or top) to turn the device on or off.
  4. Adjusting the Kickstand: The device features an integrated kickstand for convenient viewing angles. Extend the kickstand from the back of the unit to position it on a flat surface.
    Hantek TO1000 Series Side View with Kickstand

    Side view showing the kickstand in use.

  5. Connecting Probes: Depending on the function (oscilloscope or multimeter), connect the appropriate probes to the designated input ports on the device. Ensure a secure connection.
    Hantek TO1000 Series Side Ports

    Input ports for probes and other connections.

7. Operating Instructions

The Hantek TO1000 series features a full touch screen interface for easy navigation and operation. The main menu provides access to all integrated functions.

7.1. General Touch Screen Operation

  • Tap: Select an icon or menu option.
  • Drag: Adjust parameters, move waveforms, or scroll through menus.
  • Pinch-to-Zoom: Use two fingers to zoom in or out on waveforms.
    Hantek TO1000 Series Touch Screen Interaction

    Demonstration of touch screen gestures for waveform manipulation.

7.2. Oscilloscope Function

  1. From the main menu, tap the 'OSC' icon to enter oscilloscope mode.
  2. Connect the oscilloscope probes to the desired test points.
  3. Adjust vertical (Volts/Div) and horizontal (Time/Div) scales using touch gestures or dedicated on-screen controls.
  4. Configure trigger settings (type, source, level) to stabilize the waveform.
  5. Utilize the measurement functions to automatically display parameters like frequency, peak-to-peak voltage, etc.
  6. Use the 'Save' or 'Print' options for waveform storage or output.

7.3. Multimeter Function

  1. Tap the 'DMM' icon from the main menu.
  2. Connect the multimeter probes to the appropriate input terminals (V/Ω/C, COM, mA, A).
  3. Select the desired measurement mode (voltage, current, resistance, capacitance, diode, continuity) on the screen.
  4. For data recording, access the recording feature within the DMM mode to monitor and log data over time.

7.4. Signal Generator Function (AFG)

  1. Select the 'AFG' icon from the main menu.
  2. Choose the desired waveform type (sine, square, ramp, arbitrary) and adjust parameters such as frequency, amplitude, and offset.
  3. Connect the output of the signal generator to the circuit under test.
  4. Configure AM/FM modulation if required.

8. Maintenance

  • Cleaning: Use a soft, dry cloth to clean the device. For stubborn dirt, a slightly damp cloth with mild detergent can be used, ensuring no liquid enters the device openings. Do not use abrasive cleaners or solvents.
  • Battery Care: To prolong battery life, avoid fully discharging the battery frequently. If storing the device for an extended period, charge it to about 50-70% and store in a cool, dry place. Recharge periodically to prevent deep discharge.
  • Storage: Store the device and its accessories in the provided instrument package to protect them from dust and physical damage.
  • Software Updates: Check the manufacturer's website periodically for any available firmware or software updates to ensure optimal performance and access to new features.

9. Troubleshooting

If you encounter issues with your Hantek TO1000 series device, please refer to the following common troubleshooting steps:

  • Device does not power on: Ensure the battery is sufficiently charged. Connect the device to the charger and try again. If the issue persists, contact support.
  • No waveform displayed in oscilloscope mode: Check that probes are securely connected to both the device and the circuit under test. Verify that the input channels are enabled and the vertical/horizontal scales are appropriately set for the signal being measured. Adjust trigger settings.
  • Inaccurate multimeter readings: Ensure probes are correctly inserted into the appropriate jacks for the measurement type (e.g., voltage, current, resistance). Check probe integrity for any damage.
  • Touch screen unresponsive: Try restarting the device. If the screen remains unresponsive, ensure it is clean and dry.
  • Device freezes or crashes: Perform a soft reset by holding the power button until the device powers off, then restart it. If the problem recurs, consider checking for firmware updates.

For persistent issues not resolved by these steps, please contact Hantek customer support.

10. User Tips

  • Leverage Portability: The lightweight design and hanging feature make this device ideal for field work or tight spaces. Don't hesitate to use the kickstand or hang it to free up your hands.
  • Maximize Battery Life: With its large 10000mAh battery, you can work for extended periods without needing a power outlet. Remember to utilize the fast-charging feature during breaks to quickly top up the battery.
  • Explore Multi-functions: Don't limit yourself to just the oscilloscope. Experiment with the multimeter for precise measurements and the signal generator for testing circuits. The integrated spectrum analyzer can also provide valuable insights into signal characteristics.
  • Touch Screen Efficiency: Get comfortable with the multi-touch gestures like pinch-to-zoom and dragging. These can significantly speed up waveform analysis compared to traditional knob-based controls.
  • Data Logging: For long-term monitoring of voltage, current, or resistance, make use of the multimeter's data recording function. This can be invaluable for identifying intermittent issues or analyzing trends.

11. Warranty and Support

After Service Policy:

  • All delivered products are tested before shipping to ensure full functionality.
  • In case of missing or defective parts, notify the seller no later than 5 days after receiving the item for re-shipment.
  • A 1-year after-sell service is offered from the date of purchase. The seller will cover one-way freight (from China to your place) for warranty repairs.

For any questions or support needs, please contact the seller directly. Your satisfaction is important, and they are committed to assisting you until you are satisfied.


Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.