Hi-Link HLK-3LSxx

Contents

HLK-3LSxx Series 3W AC DC Converter Power Supply Module User Manual

Brand: Hi-Link | Model: HLK-3LSxx

1. Introduction

The HLK-3LSxx series 3W ultra-small AC DC power module is a compact and high-efficiency power supply designed by Shenzhen Hi-Link Electronic Co., Ltd. These modules are characterized by a global input voltage range, low temperature rise, low power consumption, high efficiency, high reliability, and high safety isolation. They are widely used in various applications including smart home devices, automation control systems, communication equipment, and instrumentation.

This manual provides essential information for the safe and effective use of your HLK-3LSxx series power module.

2. Safety Information

Please read and understand all safety instructions before installing or operating the module. Failure to follow these instructions may result in electric shock, fire, or serious injury.

2.1. General Safety Precautions

  • Ensure the input voltage is within the specified range (85-305VAC or 100-430VDC).
  • Do not operate the module in environments exceeding the specified working temperature range (-25°C to +60°C).
  • Avoid exposing the module to excessive moisture, vibration, or dust, although it is designed to meet IP65 standards for environmental protection.
  • Always disconnect power before making any connections or adjustments.
  • The module is designed for natural cooling. Ensure adequate airflow around the module.

2.2. Certification and Electromagnetic Compatibility

The product design meets UL and CE safety certification requirements. For specific UL and CE certifications, the customer needs to design according to the reference circuit.

  • The input design incorporates a UL listed 1A fuse.
  • The PCB board is made of double-sided copper clad foil with a material fire resistance grade of 94-V0.
  • Safety standards met: UL1012, EN60950, UL60950.
  • Insulation voltage I/P-O/P: 2500Vac.
  • Insulation resistance I/P-O/P: >100M Ohms/500Vdc at 25°C, 70% RH.
  • Conduction and radiation meet EN55011, EN55022 (CISPR22).
  • Electrostatic discharge: IEC/EN 61000-4-2 level 4 (8kV/15kV).
  • Radio frequency radiation immunity: IEC/EN 61000-4-3.

3. Setup and Installation

The HLK-3LSxx series power modules are designed for easy integration into various electronic circuits. Follow the guidelines below for proper setup.

3.1. Input Connections

The input pins are AC(L) and AC(N) for AC input, or +V(cap) and -V(cap) for DC input. Ensure correct polarity for DC input.

HLK-3LSxx power module showing input and output pins
Figure 1: HLK-3LSxx power module with labeled input and output pins.

A UL listed 1A fuse (F1) and a varistor (MOV1) are recommended for basic protective circuits and must be connected. If authentication/certification is required, a safety capacitance (C1) and common-mode inductance (L1) should also be included.

Table 1: Recommended Input Components
ComponentFunctionRecommended Value
F1 / FuseProtects the circuit from damage when the module is working incorrectly.1A/250Vac, Slow fuse
MOV1 / VaristorProtects the module from cumulative surge.10D561K
C1 / X Safety capacitanceFiltering, safety protection (EMC certification).0.1uF/275Vac
L1 / Common-mode inductanceEMI filtering.Sensible value: 10-30mH
Test requirements: 1KHZ/0.3V current: 100-500mA

Note: Fuse and varistor are basic protective circuits and must be connected. If you need to pass authentication/certification, the safety capacitance and common-mode inductance cannot be omitted.

3.2. Output Connections

The output pins are +Vo and -Vo. Connect your load (RL) to these pins. An aluminum electrolytic capacitor (C2) is recommended for output ripple control.

Table 2: Recommended Output Components
ComponentFunctionRecommended Value
C2 / Filter capacitorOutput ripple can be controlled in 30mV after adding this capacitor.Aluminum electrolytic capacitance, capacity 100-220 uF, voltage reduction greater than 75%.
RL / LoadConnect your electronic load here.(Specific to application)

3.3. Typical Application Circuit

The typical application circuit for the HLK-3LSxx module involves connecting the AC input (LO, NO) through an input filter stage (F1, MOV1, C1, L1) to the module's AC(L) and AC(N) pins. The DC output (+Vo, -Vo) is then connected to the load (RL) with an optional output filter capacitor (C2). This configuration ensures stable power delivery and protection.

HLK-3LSxx power module as part of a circuit
Figure 2: HLK-3LSxx power module, representing its integration into a typical application circuit.

4. Operating Instructions

The HLK-3LSxx series power modules are designed for "Almost Ready" state of assembly, meaning they are ready for integration into your system without complex initial setup procedures.

  • Power On: Once correctly wired, apply the specified AC (85-305VAC) or DC (100-430VDC) input voltage. The module will automatically convert it to the stable DC output voltage.
  • Output Voltage: The module provides a stable DC output voltage (e.g., 3.3V, 5V, 9V, 12V, 15V, 24V depending on the specific model).
  • Load Connection: Connect your electronic load to the +Vo and -Vo terminals. Ensure the load does not exceed the module's rated output current.
  • No External Circuit Required: The module is designed to operate without the need for additional external circuits for basic functionality.
Video 1: Overview of Hi-Link AC DC 3LSxx Power Module production and packaging process.

5. Maintenance

The HLK-3LSxx series power modules are designed for high reliability and long life, with a continuous working time greater than 100,000 hours. Minimal maintenance is required.

  • Cleaning: Keep the module free from dust and debris. Use a soft, dry brush or compressed air for cleaning. Do not use liquid cleaners.
  • Cooling: The module uses natural cooling. Ensure that the operating environment allows for adequate heat dissipation. Do not obstruct airflow around the module.
  • Inspection: Periodically inspect the module and its connections for any signs of damage, loose wires, or overheating.
  • Environmental Conditions: Operate the module within the specified environmental conditions (temperature, humidity, atmospheric pressure, altitude) to ensure optimal performance and longevity.

6. Troubleshooting

This section provides solutions to common issues you might encounter with your HLK-3LSxx power module.

Table 3: Troubleshooting Guide
ProblemPossible CauseSolution
No output voltage
  • No input power.
  • Incorrect input wiring.
  • Blown input fuse.
  • Module failure.
  • Verify input power supply is active.
  • Check input connections for correct polarity and secure contact.
  • Inspect and replace the input fuse (F1) if blown.
  • If all checks fail, contact technical support.
Output voltage unstable or incorrect
  • Load exceeding module capacity.
  • Poor output filtering (C2).
  • Input voltage fluctuations.
  • Reduce load or use a higher power module.
  • Ensure C2 is correctly installed and of appropriate value (100-220uF).
  • Verify stable input voltage.
Module overheating
  • Insufficient ventilation.
  • Ambient temperature too high.
  • Overload condition.
  • Ensure adequate airflow around the module.
  • Operate within specified working temperature range (-25°C to +60°C).
  • Check if the load current exceeds the module's rating.
Short circuit protection activated
  • Short circuit at the output.
  • Over-current condition.
  • Remove the short circuit. The module features self-recovery.
  • Ensure load current is within 110-150% of rated output current for over-current protection.

7. Specifications

7.1. Product Models and Output

Table 4: Product Model and Output Specifications
Module ModelOutput Voltage & Current
HLK-3LS033.3V/600mA
HLK-3LS055V/600mA
HLK-3LS099V/333mA
HLK-3LS1212V/250mA
HLK-3LS1515V/200mA
HLK-3LS2424V/125mA

All models have an output power of 3W and an input voltage range of 85-305VAC (100-430VDC).

7.2. General Electrical Characteristics

Table 5: General Electrical Characteristics
ItemTechnical ParametersUnits
Rated input voltage100-230Vac
Input voltage range90-245Vac
Maximum input current≤0.2A
Input inrush current≤10A
Input low start≤50mS
Input low voltage efficiency (Vin=110Vac, Output full load)≥69%
Input high voltage efficiency (Vin=220Vac, Output full load)≥70%
Long-term reliability (MTBF)≥100,000h
External fuse recommended0.5A/250VacSlow blow

Note: Tested at room temperature.

7.3. Environmental Conditions

Table 6: Environmental Conditions
ItemTechnical ParametersUnitsNotes
Working temperature-25 ~ +60°C
Storage temperature-40 ~ +80°C
Relative humidity5 ~ 95%
Thermal methodsNatural cooling
Atmospheric pressure80 ~ 106Kpa
Altitude≤2000m
Vibration10-500Hz, 2G 10min./1cycle, 60min. each along X,Y,Z axesMeets requirements for secondary road transportation

7.4. Output Features by Voltage Model

The following tables detail the output characteristics for each voltage model in the HLK-3LSxx series.

7.4.1. HLK-3LS03 (3.3V/1000mA)

Table 7: HLK-3LS03 Output Specifications
ItemTechnical ParametersUnitsNotes
No-load rated output voltage3.3±0.1Vdc
Full-load rated output voltage3.3±0.2Vdc
Short time maximum output current≥1100mA
Rated output current1000mA
Voltage regulation±0.2%
Load regulation±0.5%
Input low voltage efficiency (Vin=115Vac, Output full load)≥72%
Input high voltage efficiency (Vin=230Vac, Output full load)≥72%
Output ripple and noise (mVp-p)≤100 (Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test.)mV
Switching on/off overshoot amplitude(Rated input voltage, output plus 10% load)≤ 5%Vo
Output over-current protectionOutput maximum load 110-150%A
Output short circuit protectionDirect short circuit in normal output and automatic return to normal operation after removal of short circuitNo-damage to the whole device

7.4.2. HLK-3LS05 (5V/600mA)

Table 8: HLK-3LS05 Output Specifications
ItemTechnical ParametersUnitsNotes
No-load rated output voltage5.0±0.1Vdc
Full-load rated output voltage5.0±0.2Vdc
Short time maximum output current≥700mA
Rated output current600mA
Voltage regulation±0.2%
Load regulation±0.5%
Input low voltage efficiency (Vin=115Vac, Output full load)≥73%
Input high voltage efficiency (Vin=230Vac, Output full load)≥73%
Output ripple and noise (mVp-p)≤100 (Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test.)mV
Switching on/off overshoot amplitude(Rated input voltage, output plus 10% load)≤ 5%Vo
Output over-current protectionOutput maximum load 110-150%A
Output short circuit protectionDirect short circuit in normal output and automatic return to normal operation after removal of short circuitNo-damage to the whole device

7.4.3. HLK-3LS09 (9V/330mA)

Table 9: HLK-3LS09 Output Specifications
ItemTechnical ParametersUnitsNotes
No-load rated output voltage9.0±0.1Vdc
Full-load rated output voltage9.0±0.2Vdc
Short time maximum output current≥430mA
Rated output current330mA
Voltage regulation±0.2%
Load regulation±0.5%
Input low voltage efficiency (Vin=115Vac, Output full load)≥73%
Input high voltage efficiency (Vin=230Vac, Output full load)≥73%
Output ripple and noise (mVp-p)≤120 (Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test.)mV
Switching on/off overshoot amplitude(Rated input voltage, output plus 10% load)≤ 5%Vo
Output over-current protectionOutput maximum load 110-150%A
Output short circuit protectionDirect short circuit in normal output and automatic return to normal operation after removal of short circuitNo-damage to the whole device

7.4.4. HLK-3LS12 (12V/250mA)

Table 10: HLK-3LS12 Output Specifications
ItemTechnical ParametersUnitsNotes
No-load rated output voltage12.0±0.1Vdc
Full-load rated output voltage12.0±0.2Vdc
Short time maximum output current≥350mA
Rated output current250mA
Voltage regulation±0.2%
Load regulation±0.5%
Input low voltage efficiency (Vin=115Vac, Output full load)≥73%
Input high voltage efficiency (Vin=230Vac, Output full load)≥73%
Output ripple and noise (mVp-p)≤120 (Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test.)mV
Switching on/off overshoot amplitude(Rated input voltage, output plus 10% load)≤ 5%Vo
Output over-current protectionOutput maximum load 110-150%A
Output short circuit protectionDirect short circuit in normal output and automatic return to normal operation after removal of short circuitNo-damage to the whole device

7.4.5. HLK-3LS15 (15V/200mA)

Table 11: HLK-3LS15 Output Specifications
ItemTechnical ParametersUnitsNotes
No-load rated output voltage15.0±0.1Vdc
Full-load rated output voltage15.0±0.2Vdc
Short time maximum output current≥300mA
Rated output current200mA
Voltage regulation±0.2%
Load regulation±0.5%
Input low voltage efficiency (Vin=115Vac, Output full load)≥73%
Input high voltage efficiency (Vin=230Vac, Output full load)≥73%
Output ripple and noise (mVp-p)≤150 (Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test.)mV
Switching on/off overshoot amplitude(Rated input voltage, output plus 10% load)≤ 5%Vo
Output over-current protectionOutput maximum load 110-130%A
Output short circuit protectionDirect short circuit in normal output and automatic return to normal operation after removal of short circuitNo-damage to the whole device

7.4.6. HLK-3LS24 (24V/125mA)

Table 12: HLK-3LS24 Output Specifications
ItemTechnical ParametersUnitsNotes
No-load rated output voltage24.0±0.1Vdc
Full-load rated output voltage24.0±0.1Vdc
Short time maximum output current≥220mA
Rated output current125mA
Voltage regulation±0.2%
Load regulation±0.5%
Input low voltage efficiency (Vin=115Vac, Output full load)≥73%
Input high voltage efficiency (Vin=230Vac, Output full load)≥73%
Output ripple and noise (mVp-p)≤150 (Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test.)mV
Switching on/off overshoot amplitude(Rated input voltage, output plus 10% load)≤ 5%Vo
Output over-current protectionOutput maximum load 110-130%A
Output short circuit protectionDirect short circuit in normal output and automatic return to normal operation after removal of short circuitNo-damage to the whole device

7.5. Dimensions and Weight

Table 13: Dimensions and Pin Functions
ItemValue
Size (L*W*H)26.4 * 17.5 * 10 mm
Weight9 ± 2g

Dimensional error: The error of length, width, height and pin spacing is ±2mm. Pin length error: ±1mm. Pin diameter error: -0.2mm. Unit: mm. The dimensions on the drawing are for reference only. The actual dimensions shall be subject to the physical product.

HLK-3LSxx module top view with dimensions and pinout
Figure 3: Top view of the HLK-3LSxx module with approximate dimensions and pin labels (AC, -Vo, +Vo).
Table 14: Pin Function
PinFunction
1AC (Input)
2AC (Input)
3-Vo (Output Negative)
4+Vo (Output Positive)

8. User Tips

  • Quality Assurance: Users have noted the product appears to be of good quality. Ensure proper handling during installation to maintain its integrity.
  • Component Integration: For optimal performance and safety, especially when seeking certifications, integrate the recommended external components (fuse, varistor, safety capacitor, common-mode inductor) as detailed in the "Setup and Installation" section.
  • Environmental Considerations: While robust, operating within the specified temperature and humidity ranges will maximize the module's lifespan and reliability.

9. Warranty and Support

9.1. Warranty Period

The HLK-3LSxx series power modules come with a 1-year quality guarantee period from the date of purchase.

9.2. Technical Support and Contact Information

For technical assistance, inquiries, or support, please contact Shenzhen Hi-Link Electronic Co., Ltd. using the following information:

  • Address: 17F, Building E, Xinghe WORLD, Minzhi Street, Longhua district, Shenzhen 518131, China
  • Telephone: 0755-23152658
  • Email: sales@hlktech.com
  • Website: www.hlktech.net

© 2022 Shenzhen Hi-Link Electronic Co., Ltd. All rights reserved.

This manual is for informational purposes only. Specifications are subject to change without notice.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.