1. Introduction
The HLK-3LSxx series 3W ultra-small AC DC power module is a compact and high-efficiency power supply designed by Shenzhen Hi-Link Electronic Co., Ltd. These modules are characterized by a global input voltage range, low temperature rise, low power consumption, high efficiency, high reliability, and high safety isolation. They are widely used in various applications including smart home devices, automation control systems, communication equipment, and instrumentation.
This manual provides essential information for the safe and effective use of your HLK-3LSxx series power module.
2. Safety Information
Please read and understand all safety instructions before installing or operating the module. Failure to follow these instructions may result in electric shock, fire, or serious injury.
2.1. General Safety Precautions
- Ensure the input voltage is within the specified range (85-305VAC or 100-430VDC).
- Do not operate the module in environments exceeding the specified working temperature range (-25°C to +60°C).
- Avoid exposing the module to excessive moisture, vibration, or dust, although it is designed to meet IP65 standards for environmental protection.
- Always disconnect power before making any connections or adjustments.
- The module is designed for natural cooling. Ensure adequate airflow around the module.
2.2. Certification and Electromagnetic Compatibility
The product design meets UL and CE safety certification requirements. For specific UL and CE certifications, the customer needs to design according to the reference circuit.
- The input design incorporates a UL listed 1A fuse.
- The PCB board is made of double-sided copper clad foil with a material fire resistance grade of 94-V0.
- Safety standards met: UL1012, EN60950, UL60950.
- Insulation voltage I/P-O/P: 2500Vac.
- Insulation resistance I/P-O/P: >100M Ohms/500Vdc at 25°C, 70% RH.
- Conduction and radiation meet EN55011, EN55022 (CISPR22).
- Electrostatic discharge: IEC/EN 61000-4-2 level 4 (8kV/15kV).
- Radio frequency radiation immunity: IEC/EN 61000-4-3.
3. Setup and Installation
The HLK-3LSxx series power modules are designed for easy integration into various electronic circuits. Follow the guidelines below for proper setup.
3.1. Input Connections
The input pins are AC(L) and AC(N) for AC input, or +V(cap) and -V(cap) for DC input. Ensure correct polarity for DC input.

A UL listed 1A fuse (F1) and a varistor (MOV1) are recommended for basic protective circuits and must be connected. If authentication/certification is required, a safety capacitance (C1) and common-mode inductance (L1) should also be included.
| Component | Function | Recommended Value |
|---|---|---|
| F1 / Fuse | Protects the circuit from damage when the module is working incorrectly. | 1A/250Vac, Slow fuse |
| MOV1 / Varistor | Protects the module from cumulative surge. | 10D561K |
| C1 / X Safety capacitance | Filtering, safety protection (EMC certification). | 0.1uF/275Vac |
| L1 / Common-mode inductance | EMI filtering. | Sensible value: 10-30mH Test requirements: 1KHZ/0.3V current: 100-500mA |
Note: Fuse and varistor are basic protective circuits and must be connected. If you need to pass authentication/certification, the safety capacitance and common-mode inductance cannot be omitted.
3.2. Output Connections
The output pins are +Vo and -Vo. Connect your load (RL) to these pins. An aluminum electrolytic capacitor (C2) is recommended for output ripple control.
| Component | Function | Recommended Value |
|---|---|---|
| C2 / Filter capacitor | Output ripple can be controlled in 30mV after adding this capacitor. | Aluminum electrolytic capacitance, capacity 100-220 uF, voltage reduction greater than 75%. |
| RL / Load | Connect your electronic load here. | (Specific to application) |
3.3. Typical Application Circuit
The typical application circuit for the HLK-3LSxx module involves connecting the AC input (LO, NO) through an input filter stage (F1, MOV1, C1, L1) to the module's AC(L) and AC(N) pins. The DC output (+Vo, -Vo) is then connected to the load (RL) with an optional output filter capacitor (C2). This configuration ensures stable power delivery and protection.

4. Operating Instructions
The HLK-3LSxx series power modules are designed for "Almost Ready" state of assembly, meaning they are ready for integration into your system without complex initial setup procedures.
- Power On: Once correctly wired, apply the specified AC (85-305VAC) or DC (100-430VDC) input voltage. The module will automatically convert it to the stable DC output voltage.
- Output Voltage: The module provides a stable DC output voltage (e.g., 3.3V, 5V, 9V, 12V, 15V, 24V depending on the specific model).
- Load Connection: Connect your electronic load to the +Vo and -Vo terminals. Ensure the load does not exceed the module's rated output current.
- No External Circuit Required: The module is designed to operate without the need for additional external circuits for basic functionality.
5. Maintenance
The HLK-3LSxx series power modules are designed for high reliability and long life, with a continuous working time greater than 100,000 hours. Minimal maintenance is required.
- Cleaning: Keep the module free from dust and debris. Use a soft, dry brush or compressed air for cleaning. Do not use liquid cleaners.
- Cooling: The module uses natural cooling. Ensure that the operating environment allows for adequate heat dissipation. Do not obstruct airflow around the module.
- Inspection: Periodically inspect the module and its connections for any signs of damage, loose wires, or overheating.
- Environmental Conditions: Operate the module within the specified environmental conditions (temperature, humidity, atmospheric pressure, altitude) to ensure optimal performance and longevity.
6. Troubleshooting
This section provides solutions to common issues you might encounter with your HLK-3LSxx power module.
| Problem | Possible Cause | Solution |
|---|---|---|
| No output voltage |
|
|
| Output voltage unstable or incorrect |
|
|
| Module overheating |
|
|
| Short circuit protection activated |
|
|
7. Specifications
7.1. Product Models and Output
| Module Model | Output Voltage & Current |
|---|---|
| HLK-3LS03 | 3.3V/600mA |
| HLK-3LS05 | 5V/600mA |
| HLK-3LS09 | 9V/333mA |
| HLK-3LS12 | 12V/250mA |
| HLK-3LS15 | 15V/200mA |
| HLK-3LS24 | 24V/125mA |
All models have an output power of 3W and an input voltage range of 85-305VAC (100-430VDC).
7.2. General Electrical Characteristics
| Item | Technical Parameters | Units |
|---|---|---|
| Rated input voltage | 100-230 | Vac |
| Input voltage range | 90-245 | Vac |
| Maximum input current | ≤0.2 | A |
| Input inrush current | ≤10 | A |
| Input low start | ≤50 | mS |
| Input low voltage efficiency (Vin=110Vac, Output full load) | ≥69 | % |
| Input high voltage efficiency (Vin=220Vac, Output full load) | ≥70 | % |
| Long-term reliability (MTBF) | ≥100,000 | h |
| External fuse recommended | 0.5A/250Vac | Slow blow |
Note: Tested at room temperature.
7.3. Environmental Conditions
| Item | Technical Parameters | Units | Notes |
|---|---|---|---|
| Working temperature | -25 ~ +60 | °C | |
| Storage temperature | -40 ~ +80 | °C | |
| Relative humidity | 5 ~ 95 | % | |
| Thermal methods | Natural cooling | ||
| Atmospheric pressure | 80 ~ 106 | Kpa | |
| Altitude | ≤2000 | m | |
| Vibration | 10-500Hz, 2G 10min./1cycle, 60min. each along X,Y,Z axes | Meets requirements for secondary road transportation |
7.4. Output Features by Voltage Model
The following tables detail the output characteristics for each voltage model in the HLK-3LSxx series.
7.4.1. HLK-3LS03 (3.3V/1000mA)
| Item | Technical Parameters | Units | Notes |
|---|---|---|---|
| No-load rated output voltage | 3.3±0.1 | Vdc | |
| Full-load rated output voltage | 3.3±0.2 | Vdc | |
| Short time maximum output current | ≥1100 | mA | |
| Rated output current | 1000 | mA | |
| Voltage regulation | ±0.2 | % | |
| Load regulation | ±0.5 | % | |
| Input low voltage efficiency (Vin=115Vac, Output full load) | ≥72 | % | |
| Input high voltage efficiency (Vin=230Vac, Output full load) | ≥72 | % | |
| Output ripple and noise (mVp-p) | ≤100 (Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test.) | mV | |
| Switching on/off overshoot amplitude | (Rated input voltage, output plus 10% load)≤ 5 | %Vo | |
| Output over-current protection | Output maximum load 110-150% | A | |
| Output short circuit protection | Direct short circuit in normal output and automatic return to normal operation after removal of short circuit | No-damage to the whole device |
7.4.2. HLK-3LS05 (5V/600mA)
| Item | Technical Parameters | Units | Notes |
|---|---|---|---|
| No-load rated output voltage | 5.0±0.1 | Vdc | |
| Full-load rated output voltage | 5.0±0.2 | Vdc | |
| Short time maximum output current | ≥700 | mA | |
| Rated output current | 600 | mA | |
| Voltage regulation | ±0.2 | % | |
| Load regulation | ±0.5 | % | |
| Input low voltage efficiency (Vin=115Vac, Output full load) | ≥73 | % | |
| Input high voltage efficiency (Vin=230Vac, Output full load) | ≥73 | % | |
| Output ripple and noise (mVp-p) | ≤100 (Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test.) | mV | |
| Switching on/off overshoot amplitude | (Rated input voltage, output plus 10% load)≤ 5 | %Vo | |
| Output over-current protection | Output maximum load 110-150% | A | |
| Output short circuit protection | Direct short circuit in normal output and automatic return to normal operation after removal of short circuit | No-damage to the whole device |
7.4.3. HLK-3LS09 (9V/330mA)
| Item | Technical Parameters | Units | Notes |
|---|---|---|---|
| No-load rated output voltage | 9.0±0.1 | Vdc | |
| Full-load rated output voltage | 9.0±0.2 | Vdc | |
| Short time maximum output current | ≥430 | mA | |
| Rated output current | 330 | mA | |
| Voltage regulation | ±0.2 | % | |
| Load regulation | ±0.5 | % | |
| Input low voltage efficiency (Vin=115Vac, Output full load) | ≥73 | % | |
| Input high voltage efficiency (Vin=230Vac, Output full load) | ≥73 | % | |
| Output ripple and noise (mVp-p) | ≤120 (Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test.) | mV | |
| Switching on/off overshoot amplitude | (Rated input voltage, output plus 10% load)≤ 5 | %Vo | |
| Output over-current protection | Output maximum load 110-150% | A | |
| Output short circuit protection | Direct short circuit in normal output and automatic return to normal operation after removal of short circuit | No-damage to the whole device |
7.4.4. HLK-3LS12 (12V/250mA)
| Item | Technical Parameters | Units | Notes |
|---|---|---|---|
| No-load rated output voltage | 12.0±0.1 | Vdc | |
| Full-load rated output voltage | 12.0±0.2 | Vdc | |
| Short time maximum output current | ≥350 | mA | |
| Rated output current | 250 | mA | |
| Voltage regulation | ±0.2 | % | |
| Load regulation | ±0.5 | % | |
| Input low voltage efficiency (Vin=115Vac, Output full load) | ≥73 | % | |
| Input high voltage efficiency (Vin=230Vac, Output full load) | ≥73 | % | |
| Output ripple and noise (mVp-p) | ≤120 (Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test.) | mV | |
| Switching on/off overshoot amplitude | (Rated input voltage, output plus 10% load)≤ 5 | %Vo | |
| Output over-current protection | Output maximum load 110-150% | A | |
| Output short circuit protection | Direct short circuit in normal output and automatic return to normal operation after removal of short circuit | No-damage to the whole device |
7.4.5. HLK-3LS15 (15V/200mA)
| Item | Technical Parameters | Units | Notes |
|---|---|---|---|
| No-load rated output voltage | 15.0±0.1 | Vdc | |
| Full-load rated output voltage | 15.0±0.2 | Vdc | |
| Short time maximum output current | ≥300 | mA | |
| Rated output current | 200 | mA | |
| Voltage regulation | ±0.2 | % | |
| Load regulation | ±0.5 | % | |
| Input low voltage efficiency (Vin=115Vac, Output full load) | ≥73 | % | |
| Input high voltage efficiency (Vin=230Vac, Output full load) | ≥73 | % | |
| Output ripple and noise (mVp-p) | ≤150 (Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test.) | mV | |
| Switching on/off overshoot amplitude | (Rated input voltage, output plus 10% load)≤ 5 | %Vo | |
| Output over-current protection | Output maximum load 110-130% | A | |
| Output short circuit protection | Direct short circuit in normal output and automatic return to normal operation after removal of short circuit | No-damage to the whole device |
7.4.6. HLK-3LS24 (24V/125mA)
| Item | Technical Parameters | Units | Notes |
|---|---|---|---|
| No-load rated output voltage | 24.0±0.1 | Vdc | |
| Full-load rated output voltage | 24.0±0.1 | Vdc | |
| Short time maximum output current | ≥220 | mA | |
| Rated output current | 125 | mA | |
| Voltage regulation | ±0.2 | % | |
| Load regulation | ±0.5 | % | |
| Input low voltage efficiency (Vin=115Vac, Output full load) | ≥73 | % | |
| Input high voltage efficiency (Vin=230Vac, Output full load) | ≥73 | % | |
| Output ripple and noise (mVp-p) | ≤150 (Rated input voltage, output full load. With 20MHz bandwidth oscilloscope, Load side 10uF and 0.1uF capacitance test.) | mV | |
| Switching on/off overshoot amplitude | (Rated input voltage, output plus 10% load)≤ 5 | %Vo | |
| Output over-current protection | Output maximum load 110-130% | A | |
| Output short circuit protection | Direct short circuit in normal output and automatic return to normal operation after removal of short circuit | No-damage to the whole device |
7.5. Dimensions and Weight
| Item | Value |
|---|---|
| Size (L*W*H) | 26.4 * 17.5 * 10 mm |
| Weight | 9 ± 2g |
Dimensional error: The error of length, width, height and pin spacing is ±2mm. Pin length error: ±1mm. Pin diameter error: -0.2mm. Unit: mm. The dimensions on the drawing are for reference only. The actual dimensions shall be subject to the physical product.

| Pin | Function |
|---|---|
| 1 | AC (Input) |
| 2 | AC (Input) |
| 3 | -Vo (Output Negative) |
| 4 | +Vo (Output Positive) |
8. User Tips
- Quality Assurance: Users have noted the product appears to be of good quality. Ensure proper handling during installation to maintain its integrity.
- Component Integration: For optimal performance and safety, especially when seeking certifications, integrate the recommended external components (fuse, varistor, safety capacitor, common-mode inductor) as detailed in the "Setup and Installation" section.
- Environmental Considerations: While robust, operating within the specified temperature and humidity ranges will maximize the module's lifespan and reliability.
9. Warranty and Support
9.1. Warranty Period
The HLK-3LSxx series power modules come with a 1-year quality guarantee period from the date of purchase.
9.2. Technical Support and Contact Information
For technical assistance, inquiries, or support, please contact Shenzhen Hi-Link Electronic Co., Ltd. using the following information:
- Address: 17F, Building E, Xinghe WORLD, Minzhi Street, Longhua district, Shenzhen 518131, China
- Telephone: 0755-23152658
- Email: sales@hlktech.com
- Website: www.hlktech.net