VariCore LiFePO4 Battery User Manual

Model: YQ-2 Series (100Ah, 120Ah, 160Ah, 180Ah)

Brand: VariCore

Introduction

This instruction manual provides detailed information regarding the basic parameters, MPPT setting and wiring, series and parallel connection, charging and discharging operations, applicable equipment, and application scenarios for the VariCore 12V LiFePO4 lithium battery. This battery features high-purity lithium iron phosphate materials and an intelligent BMS protection system, compatible with MPPT charging, and offers stable discharge performance.

Please read this manual carefully before use and strictly follow the operating specifications to ensure the service life and safe operation of the product. The company is not liable for any product damage or potential safety hazards caused by failure to operate in accordance with this manual.

For a complete visual guide and additional details, please refer to the official PDF manual: VariCore 12V 120Ah LiFePO4 Lithium Battery Instruction Manual (PDF)

Specifications

The VariCore LiFePO4 battery is designed for robust performance across various applications. Key parameters are provided below:

Parameter Name Specific Specification Remarks
Brand Name VariCore
Model Number YQ-2 (VC-12120, VC-12180 variants)
Rated Voltage 12V DC Standard working voltage, suitable for 12V system equipment
Nominal Capacity 120Ah / 160Ah / 180Ah (25°C, 0.2C discharge) At room temperature, discharge to 9.5V with a 24A current, discharge duration ≥5 hours (for 120Ah)
Battery Type Lithium Iron Phosphate (LiFePO4) Safe and stable, no memory effect, long cycle life
Charging Method Intelligent constant current and constant voltage charger Supports MPPT charging, compatible with 12V MPPT controller
Maximum Continuous Discharge Current 100A (25°C) Peak discharge current ≤200A (single time ≤10 seconds, frequent peak discharge is prohibited)
Charging Cut-off Voltage 14.6V ±0.1V Automatically detected by BMS, the charging circuit is cut off when the voltage is reached
Discharging Cut-off Voltage 9.5V ±0.1V BMS automatically cuts off discharge to avoid damage caused by over-discharging
Cycle Life ≥6000 times (25°C, 80% depth of charge and discharge) The lower the depth of charge and discharge, the longer the cycle life
Operating Temperature Range Charging: 0°C~55°C; Discharging: -20°C~65°C Optimal operating temperature: 20°C~25°C with the best performance
Size (approx.) 330*175*216mm
Weight (approx.) 12kg / 15kg Weight may vary according to cell batches or production batches
Connection Others
High-concerned chemical None
Close-up of the side label of the VariCore LiFePO4 battery, showing model (VC-12180), voltage, capacity, and other specifications.
Side label of the VariCore LiFePO4 battery, detailing model, voltage, capacity, and other specifications.

Setup and Installation

MPPT Controller Adaptation Requirements

  • Model Requirement: Use a 12V special MPPT solar controller that supports LiFePO4 lithium battery charging mode. MPPT controllers designed for lead-acid batteries are not allowed.
  • Parameter Setting: Set the charging voltage of the MPPT controller to 14.6V (consistent with the battery charging cut-off voltage) and the charging current to 0.1C~0.5C (i.e., 12A~60A) to ensure compatibility with battery parameters.
  • Pre-check: Before use, confirm that the open-circuit voltage of the battery is normal, the MPPT controller is undamaged, and the wiring terminals are not oxidized.

MPPT Wiring Method

Core Wiring Principle: Operate with power off. Ensure positive and negative poles are connected correctly. Reverse connection and short circuits are strictly prohibited.

  1. Power-off Preparation: Disconnect all power supplies of the MPPT controller, solar panel, and battery to ensure all three are in a power-off state. Wear insulated gloves to avoid electric shock or short circuit.
  2. Wiring between Battery and MPPT Controller: Connect the "BAT+" terminal of the MPPT controller to the battery positive pole (+) through an adaptive wire (cross-sectional area ≥10mm²), and the "BAT-" terminal to the battery negative pole (-). Tighten the wiring terminals to ensure good contact without looseness or exposed wires.
  3. Wiring between Solar Panel and MPPT Controller: Connect the positive pole (+) of the solar panel to the "PV+" terminal of the MPPT controller, and the negative pole (-) of the solar panel to the "PV-" terminal. Check the correspondence of positive and negative poles after wiring and tighten the terminals.
  4. Load Wiring (Optional): If the load needs to be driven by the MPPT controller, connect the positive and negative poles of the load to the "LOAD+" and "LOAD-" terminals of the MPPT controller correspondingly. The maximum load current shall not exceed 100A to avoid overload.

Series Connection (Maximum Voltage Shall Not Exceed 80V)

When a single 12V battery cannot meet the equipment voltage requirements, the total voltage can be increased through series connection (the total capacity remains unchanged after series connection). For series connection, use 12V 120Ah LiFePO4 lithium batteries of the same model, capacity, and batch, and strictly follow the wiring method to avoid operation errors.

Core Parameters of Series Connection

Series Connection Rule: When 'n' 12V 120Ah LiFePO4 lithium batteries are connected in series, the total voltage after series connection = 12V × n, and the total capacity = 120Ah. The maximum continuous discharge current is still 100A (consistent with a single battery).

Example:

  • 2 batteries in series → total voltage 24V, total capacity 120Ah.
  • 3 batteries in series → total voltage 36V, total capacity 120Ah.

Series Connection Wiring Method

  1. Power-off Preparation: Disconnect all batteries to be connected in series from loads and charging equipment, ensure the BMS function of all batteries is normal, and check the voltage of each battery with a single battery voltage difference ≤0.3V.
  2. Battery Series Wiring: Connect the negative pole (-) of the first battery to the positive pole (+) of the second battery through an adaptive wire (cross-sectional area ≥16mm²), and so on to complete the series connection of all batteries. For example, for 2 batteries in series: battery 1 negative pole → battery 2 positive pole. For 3 batteries in series: battery 1 negative pole → battery 2 positive pole, battery 2 negative pole → battery 3 positive pole.
  3. Confirmation of Total Output Terminals: After series connection, the remaining positive pole (+) of the first battery and negative pole (-) of the last battery are used as the total output positive and negative terminals for connecting loads or chargers. Mark the terminals clearly to avoid confusion.
  4. Wiring Detection: Check whether all wiring terminals are tightened and whether the positive and negative poles are reversely connected. After confirming no short circuit or looseness, measure the total output voltage (which should be 12V x number of series batteries). If the voltage is normal, the series connection is successful; if the voltage is abnormal, cut off the power immediately and troubleshoot the wiring errors.

For visual diagrams of two and three batteries in series, please refer to the 'Series Connection' section in the official PDF manual.

Parallel Connection

When the capacity of a single 12V battery cannot meet the equipment discharge duration requirements, the total capacity can be increased through parallel connection (the total voltage remains unchanged after parallel connection). For parallel connection, use 12V 120Ah LiFePO4 lithium batteries of the same model, capacity, and batch, and strictly follow the wiring method to ensure standard wiring.

Core Parameters of Parallel Connection

Parallel Connection Rule: When 'n' 12V 120Ah LiFePO4 lithium batteries are connected in parallel, the total voltage after parallel connection = 12V (consistent with a single battery), the total capacity = 120Ah × n, and the maximum continuous discharge current is 100A (the discharge current does not superpose due to the built-in BMS).

Example:

  • 2 batteries in parallel → total voltage 12V, total capacity 240Ah, maximum discharge current 100A.
  • 3 batteries in parallel → total voltage 12V, total capacity 360Ah, maximum discharge current 100A.

Parallel Connection Wiring Method

  1. Power-off Preparation: Disconnect all batteries to be connected in parallel from loads and charging equipment to ensure all batteries are in a power-off state. Check that the BMS system of each battery has no fault alarm and the single battery voltage difference ≤0.3V to avoid circulating current between batteries after parallel connection.
  2. Battery Parallel Wiring: Use two adaptive wires (cross-sectional area ≥16mm²), one wire to connect the positive pole (+) terminals of all batteries (bus connection), and the other wire to connect the negative pole (-) terminals of all batteries (bus connection). Tighten each wiring terminal to ensure good contact without looseness or exposure.
  3. Confirmation of Total Output Terminals: The positive bus connection point after parallel connection is the total output positive pole (+), and the negative bus connection point is the total output negative pole (-).
  4. Wiring Detection: Check whether all wiring terminals are tightened and whether the positive and negative poles are confused. After confirming no short circuit or looseness, measure the total output voltage (which should be 12V). If the voltage is normal, the parallel connection is successful; if heating or abnormal voltage occurs, cut off the power immediately and troubleshoot the wiring errors.

For visual diagrams of two and three batteries in parallel, please refer to the 'Parallel Connection' section in the official PDF manual.

Operating Instructions

Charging

This battery has a built-in intelligent BMS charging protection system and supports two charging methods:

Method 1: Charging with a Special Charger (Basic Charging Method)

  1. Charger Selection: Select a 12V special charger for LiFePO4 lithium batteries that supports constant current and constant voltage mode. The charging current shall be less than 60A (recommended >24A), and the charger output voltage shall match the battery charging cut-off voltage (14.6V ±0.1V). Chargers for lead-acid batteries or non-special chargers are strictly prohibited.
  2. Pre-charging Check: Disconnect the battery from the load, check that the battery appearance is undamaged, and the wiring terminals are not oxidized or loose; check that the charger is fault-free and the charging wire is intact.
  3. Wiring Operation: Connect the positive (+) clip of the charger to the positive (+) terminal of the battery, and the negative (-) clip to the negative (-) terminal of the battery to ensure good contact. Reverse connection of positive and negative poles is strictly prohibited.
  4. Start Charging: Connect the charger to the power supply, and the charger starts to work. The BMS system will initiate protection and enter the constant current charging stage. When the battery voltage rises to 14.6V, it automatically switches to the constant voltage charging stage, and the charging current gradually decreases. When the charging current approaches 0, the BMS automatically cuts off the charging circuit, and charging is completed.
  5. Completion of Charging: Disconnect the charger power supply, then disconnect the wiring between the charger and the battery, and place the battery properly for use or storage.
12V 10A LiFePO4 Smart Charger with alligator clips and power plug.
Included 12V 10A LiFePO4 Smart Charger.
VariCore LiFePO4 battery being charged by the included charger, showing alligator clips connected to battery terminals.
Battery connected to the charger for charging.
Close-up of the battery's LCD display showing '13.4V' and battery capacity, with Type-C and USB-A ports, during charging.
Battery LCD display showing voltage and charge status during operation.

Method 2: MPPT Charging (Suitable for Solar Energy Storage Scenarios)

The operating specifications refer to the 'MPPT Setting' section of this manual. After wiring is completed, the MPPT controller will automatically track the maximum power of solar energy to charge the battery. The BMS system will monitor the whole process to ensure charging safety without manual intervention and will automatically cut off the charging circuit after charging is completed.

Discharging (Maximum 100A Continuous Discharge)

The maximum continuous discharge current of this battery is 100A (25°C). During the discharge process, the BMS system monitors the discharge current, voltage, and battery temperature in real time, and automatically triggers protection against over-discharging, overcurrent, high temperature, etc., to ensure discharge safety and extend battery life.

Core Discharge Specifications

  • Maximum Continuous Discharge Current: 100A (25°C environment). It is recommended to control long-time discharge within 50A to effectively extend battery cycle life.
  • Peak Discharge Current: ≤200A, single continuous time ≤10 seconds. Frequent peak discharge is prohibited, otherwise the BMS system and battery will be damaged.
  • Discharging Cut-off Voltage: 9.5V ±0.1V. The BMS system will automatically cut off the discharge circuit when the voltage reaches this value. Forcible discharge below this voltage is prohibited.
  • Discharge Environment: The optimal discharge temperature is 20°C~25°C. When the temperature is lower than -20°C, large current discharge (≤30A) is prohibited to avoid battery performance degradation and damage.

Discharging Operating Steps

  1. Pre-discharge Check: Measure whether the battery voltage is normal, check that the battery appearance is undamaged, bulging or leaking liquid, and the wiring terminals are not oxidized or loose. Ensure the equipment load parameters (rated voltage 12V, maximum current ≤100A) match the battery.
  2. Wiring Operation: Connect the positive (+) wire of the load to the positive (+) terminal of the battery, and the negative (-) wire of the load to the negative (-) terminal of the battery. Tighten the wiring terminals to ensure good contact. Reverse connection of positive and negative poles is strictly prohibited; the wire cross-sectional area ≥16mm² is suitable for 100A discharge current.
  3. Post-discharge Processing: Charge the battery in a timely manner within 24 hours after discharge is completed to avoid the battery being in a low-power state for a long time, which will cause plate sulfation and shorten the battery life.
Multi Kinetic Energy Inverter (500W/1000W/2000W) with alligator clips, 12V DC to 220V AC.
Multi-functional inverter for converting 12V DC to AC power.

Applicable Equipment

This 12V 120Ah LiFePO4 lithium battery is built-in with a BMS protection system and supports 100A continuous discharge, suitable for all DC electrical equipment with a rated voltage of 12V and a maximum working current of ≤100A. When matching equipment, confirm that the parameters are consistent to avoid over-specification use.

Energy Storage Equipment

  • 12V MPPT solar energy storage systems, small energy storage inverters (power ≤1200W), 12V UPS uninterruptible power supplies.
  • Applicable Scenarios: Household energy storage, outdoor energy storage, off-grid power supply systems.

Mobile Power Supply Equipment

  • RV power supply equipment, off-road vehicle auxiliary power supplies, ship auxiliary power supply systems, high-power electric wheelchairs, portable energy storage power supplies.
  • Adaptation Advantages: Large capacity, stable discharge, 100A large current can meet the power supply requirements of high-power mobile equipment with long endurance.

Industrial/Outdoor Equipment

  • 12V DC motors (maximum current ≤100A), outdoor monitoring equipment, emergency lighting systems, portable testing equipment, agricultural irrigation equipment.
  • Adaptation Advantages: Resistant to high and low temperatures, wide operating temperature range, adaptable to complex outdoor and industrial environments, and BMS protection ensures stable equipment operation.

Household/Commercial Emergency Equipment

  • Household small energy storage power supply, commercial emergency power supply, medical equipment (low-power 12V equipment), emergency broadcast equipment.
  • Adaptation Advantages: Safe and stable, no memory effect, can be used as a long-term backup, fast emergency power supply response to ensure normal equipment operation.

Maintenance

  • Regular Inspection: The product needs regular inspection and maintenance.
  • Long-term Storage: If the battery is not used for a long time, it shall be fully charged before storage and recharged every 1-2 months to avoid battery damage caused by low power.
  • Ventilation: During charging, place the battery in a well-ventilated place away from fire, heat sources, and direct sunlight to avoid battery bulging and liquid leakage caused by high temperature.
  • Optimal Temperature: The optimal operating temperature for discharge is 20°C~25°C. When the temperature is lower than -20°C, large current discharge (≤30A) is prohibited to avoid battery performance degradation and damage.
  • Disposal: After the battery is scrapped, it shall be properly disposed of in accordance with local environmental protection regulations. Random discarding is strictly prohibited. LiFePO4 lithium batteries are recyclable and environmentally friendly.

Troubleshooting

  • Abnormalities during MPPT Charging: If abnormalities such as overcharging, overcurrent, or high temperature occur during MPPT charging, the BMS system will automatically cut off the charging circuit. Check the equipment and wiring, then eliminate faults before reuse.
  • Battery Failure in Series Connection: If one of the batteries in a series connection fails (e.g., bulging, liquid leakage, abnormal voltage), stop using it immediately, disconnect all battery connections, replace the faulty battery, and then perform series connection again. Do not continue to use the battery with faults.
  • Abnormalities during Charging: If the battery is found to be abnormally hot, bulging, leaking liquid, producing a peculiar smell, or smoking during charging, stop charging immediately, cut off the power supply, and contact after-sales service for processing. It is strictly forbidden to continue using it.
  • Over-discharging: Discharging below 9.5V is strictly prohibited. Over-discharging will lead to battery capacity attenuation, performance degradation, and even permanent battery damage.
  • Overload Discharge: Continuous discharge exceeding 100A and frequent peak discharge are strictly prohibited, otherwise the BMS system and the internal structure of the battery will be damaged. The load current shall be controlled within the maximum discharge current range of the battery.
  • Equipment Mismatch: It is strictly prohibited to use the 12V battery for equipment with a voltage higher than 12V or with overcurrent. If the equipment has special power supply requirements, contact us via email for professional matching suggestions.

User Tips

  • Initial Charge: The battery may not arrive fully charged (e.g., 70-90% charge). It is recommended to charge it to 100% before its first use to ensure optimal performance.
  • Capacity Verification: Actual capacity may vary slightly from the nominal rating. If precise measurement is critical for your application, consider performing a capacity test.
  • Inverter Wiring: For high-power applications using an inverter, ensure that the inverter wiring is adequately sized for the expected load. Inadequate wiring can lead to overheating, especially under loads exceeding 500W.
  • Inverter Temperature: Monitor the inverter's temperature when operating under heavy loads, as it may heat up considerably.

Warranty and Support

The warranty period for this product is 12 months, calculated from the date of purchase.

Within the warranty period, if the product experiences quality problems caused by non-human factors, you may contact us for free repair or replacement services. Damage caused by human factors or failure to operate in accordance with specifications is not covered by the warranty.

Shenzhen Varicore Electronic Technology Co., Ltd. reserves the final right of interpretation of this manual.

Contact Information:

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.