1. Introduction
The CHINT KG316T series microcomputer time control switch is designed for automatic control circuits. It is primarily used for the timed switching (ON/OFF) of various electrical equipment, such as street lamps, advertising light boxes, and other industrial or household applications. This device operates on an AC 50Hz power supply with a rated control voltage of up to 220V and a rated operating current of up to 3A. This manual provides detailed instructions for the safe installation, operation, and maintenance of your KG316T/KG316T-D time control switch.
2. Safety Information
WARNING: Risk of Electric Shock!
- Installation and maintenance should only be performed by qualified personnel.
- Ensure the power supply is completely disconnected before performing any wiring or maintenance.
- Do not operate the device with wet hands or in damp environments.
- Verify all wiring connections are secure and correct before applying power.
- This device is designed for indoor use in a dry environment unless otherwise specified for outdoor enclosures.
3. Product Overview
The CHINT KG316T/KG316T-D is a compact, microcomputer-controlled timer switch featuring a digital display and intuitive button interface for programming. It is designed for DIN rail mounting, making it suitable for integration into electrical distribution boxes.
3.1. Components and Controls


The front panel features a digital LCD display, several control buttons, and status indicators. The buttons are typically labeled in Chinese, but their functions are standard for time switches:
- 取消恢复 (Cancel/Restore): Used to clear settings or restore default values.
- 校时 (Calibrate Hour): Adjusts the hour setting.
- 校分 (Calibrate Minute): Adjusts the minute setting.
- 校星期 (Calibrate Weekday): Adjusts the day of the week setting.
- 自动手动 (Auto/Manual): Toggles between automatic (programmed) operation and manual ON/OFF control.
- 定时 (Timing): Enters or navigates through programming modes for ON/OFF cycles.
- 时钟 (Clock): Displays the current time or exits programming mode.
Below the display, there are indicators for "电源" (Power) and "动作" (Action/Status).
3.2. Mounting and Terminals


The device is designed for easy installation onto a standard DIN rail. The bottom of the unit features screw terminals for connecting the power source and the electrical load. These are typically labeled "电源 SOURCE" (Power Source) and "负载 LOAD" (Load), with individual terminals for Neutral (N) and Live (L) for both input and output.
4. Specifications
| Feature | Specification |
|---|---|
| Brand Name | CHINT |
| Model Number | KG316T, KG316T-D |
| Max. Voltage | AC 220V / 240V |
| Max. Current | 3A |
| Frequency | 50Hz |
| DIY Supplies | Electrical |
| Certification | CCC |
| Smart Device | Yes |
| Origin | Mainland China, Zhejiang |
| Battery Included | No (Internal backup battery for clock/memory, user-replaceable if display is unclear) |
4.1. Dimensions

Refer to Figure 4.1 for detailed dimensions of the device, including mounting points and overall size. All measurements are in millimeters (MM).
5. Setup
5.1. Mounting
- Ensure the power supply to the installation area is completely turned off.
- Locate a standard 35mm DIN rail within your electrical enclosure.
- Align the timer switch's mounting clip with the DIN rail.
- Press the timer switch firmly onto the DIN rail until it clicks securely into place.
5.2. Wiring
IMPORTANT: All wiring must be done with the power OFF. Incorrect wiring can cause damage to the device, electrical shock, or fire.

- Identify the "电源 SOURCE" (Power Source) terminals and "负载 LOAD" (Load) terminals at the bottom of the device.
- Connect the incoming Live (L) wire from your AC 220V/240V power supply to the "L" terminal under "电源 SOURCE".
- Connect the incoming Neutral (N) wire from your AC 220V/240V power supply to the "N" terminal under "电源 SOURCE".
- Connect the Live (L) wire of your electrical load (e.g., street lamp, advertising light) to the "L" terminal under "负载 LOAD".
- Connect the Neutral (N) wire of your electrical load to the "N" terminal under "负载 LOAD".
- Ensure all screw terminals are tightened securely to prevent loose connections.
- After wiring, double-check all connections for correctness before restoring power.
6. Operating Instructions
Once the device is powered on, the display will illuminate. If the display is dim or blank, refer to the Troubleshooting section regarding the internal battery.
6.1. Setting Current Time and Day
- Press the "时钟" (Clock) button to ensure you are in the main time display mode.
- Press and hold the "时钟" (Clock) button, then simultaneously press "校时" (Calibrate Hour) to set the hour.
- While still holding "时钟" (Clock), press "校分" (Calibrate Minute) to set the minute.
- While still holding "时钟" (Clock), press "校星期" (Calibrate Weekday) to set the current day of the week (e.g., Mo for Monday, Tu for Tuesday, etc.).
- Release the "时钟" (Clock) button. The current time and day are now set.
6.2. Programming ON/OFF Cycles
The KG316T/KG316T-D allows you to set multiple ON/OFF programs. Each program consists of an ON time and an OFF time, and can be configured for specific days of the week.
- Press the "定时" (Timing) button. The display will show "1 ON" (or similar, indicating the first ON program).
- Use "校时" (Calibrate Hour), "校分" (Calibrate Minute), and "校星期" (Calibrate Weekday) to set the desired ON time and days for the first program. You can select individual days, weekdays, weekends, or all days.
- Press "定时" (Timing) again. The display will show "1 OFF" (indicating the first OFF program).
- Use "校时" (Calibrate Hour), "校分" (Calibrate Minute), and "校星期" (Calibrate Weekday) to set the desired OFF time and days for the first program.
- Repeat steps 1-4 for additional ON/OFF programs (e.g., "2 ON", "2 OFF", etc.) as needed. The device typically supports a certain number of programs (e.g., 8, 16, or 20).
- After setting all desired programs, press the "时钟" (Clock) button to exit programming mode and return to the current time display.
6.3. Auto/Manual Mode
The "自动手动" (Auto/Manual) button allows you to override programmed settings temporarily or permanently.
- Auto Mode (自动): The device operates according to the programmed ON/OFF cycles. This is the default and desired mode for automatic control.
- Manual ON (手动 ON): The load is continuously ON, overriding any programmed OFF times.
- Manual OFF (手动 OFF): The load is continuously OFF, overriding any programmed ON times.
Press the "自动手动" button repeatedly to cycle through these modes until the desired operating state is displayed.
6.4. Resetting the Device
To clear all programmed settings and reset the device to factory defaults, locate the small reset button (often recessed) and press it using a non-metallic pointed object (e.g., a toothpick). This will typically clear all programs and reset the clock to 00:00.
7. Maintenance
- Cleaning: Periodically wipe the device with a soft, dry cloth. Do not use abrasive cleaners or solvents.
- Internal Battery: The device contains an internal backup battery to maintain time and program settings during power outages. If the display becomes dim, unclear, or loses time/settings frequently, the internal battery may need replacement. Refer to the Troubleshooting section for more details.
- Connection Check: Annually, or as needed, inspect wiring connections to ensure they remain tight and free from corrosion.
8. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Display is unclear or no display. | Internal backup battery is low or depleted. | Replace the internal battery. This typically involves opening the front panel (often a small cover at the top) and replacing a button cell battery (e.g., CR2032). Ensure power is disconnected before attempting. |
| Device does not power on. | No power supply; incorrect wiring; faulty unit. | Check power source. Verify wiring connections (L and N for SOURCE). If power is present and wiring is correct, the unit may be faulty. |
| Load does not turn ON/OFF as programmed. | Incorrect programming; device in Manual mode; faulty load connection. | Ensure the device is in "Auto" mode. Recheck your programmed ON/OFF times and days. Verify the load is correctly wired to the "LOAD" terminals and is functional. |
| Time or settings are lost after power outage. | Internal backup battery is low or depleted. | Replace the internal battery. |
9. User Tips
- Initial Charge: When first installing or after a long period of no power, allow the device to be powered for a few hours to charge the internal backup battery.
- Test Programs: After programming, it's advisable to manually advance the time or wait for the programmed times to verify that the ON/OFF cycles function as intended before relying on the automation.
- Labeling: For complex setups, consider labeling the timer switch and its associated load for easy identification.
10. Warranty and Support
CHINT products are manufactured to high-quality standards. For specific warranty information, please refer to the documentation provided at the time of purchase or contact your local CHINT distributor. Keep your purchase receipt as proof of purchase.
For technical support or further assistance, please contact CHINT customer service or visit the official CHINT website.