1. Important Safety Instructions
WARNING: Failure to follow these instructions may result in damage to the product or personal injury.
- Please read the paper manual inside the package carefully before use.
- Keep the device and its cord out of reach of children under 3 years old.
- Keep away from children unless supervised by an adult.
- Do not use this product for purposes other than its intended use.
- Inspect the product before each use; do not use if damaged.
- Follow installation and operation guidelines to avoid injury.
This product is CE certified.
2. Product Overview
The QHJIA 12V/24V DC Gear Oil Pump is a self-priming fuel transfer pump designed for efficient transfer of various oils. It is suitable for use with diesel oil, engine oil, lubricating oil, and kerosene. Its compact design and robust construction make it ideal for a wide range of applications, including automotive, agricultural, and industrial settings.
3. Specifications
| Feature | Detail |
|---|---|
| Brand Name | QHJIA |
| Model | FP-12 / FP-24 |
| Power Source | Electric |
| Structure | Gear Pump |
| Voltage | 12V (FP-12) / 24V (FP-24) DC |
| Origin | China Mainland |
| Certification | CE |
| Pump Head Material | Copper |
| Gear Material | Copper |
| Joint Material | Copper |
| Motor | All-copper wire |
| Wiring Method | Twin-core wire |
| Dimensions (Approx.) | Height: 94mm (3.702in), Width: 109mm (4.295in), Length: 161mm (6.355in) |
4. Setup
- Remove all protective films from the device.
- Connect the water pipes (not included) to the water pump's inlet and outlet ports. Ensure connections are secure to prevent leaks.
- Connect the pump to the appropriate DC power supply (12V for FP-12, 24V for FP-24).
4.1. Electrical Connection
The pump uses a twin-core wire for electrical connection. Connect the red wire to the positive (+) terminal of your DC power source and the black wire to the negative (-) terminal.
5. Operating Instructions
- Ensure the pump is securely mounted and all connections (pipes and electrical) are correct and tight.
- Place the inlet hose into the liquid to be transferred and the outlet hose into the receiving container.
- Connect the pump to the power supply. The pump will begin to transfer the liquid.
- Monitor the transfer process. Once complete, disconnect the pump from the power supply.
- Turn off the device and store it in a dry place, away from children.
5.1. Operating Conditions
The gear oil pump can work normally under the following conditions:
- Ambient temperature: ≤ +50°C
- Medium temperature: 0°C ~ +65°C
- PH value of the medium: between 5.0 and 7.5
- Volume of solid impurities in the medium: ≤ 0.1%, and the particle size is no more than 0.2mm
- Power supply frequency: 50Hz, voltage is DC 12V/24V, and the voltage fluctuation range is ± 10% of the rated value.
5.2. Product Video
Watch this video for a visual guide on the product.
6. Maintenance
- Regularly inspect the pump for any signs of wear, damage, or leaks.
- Ensure all connections remain tight.
- Clean the exterior of the pump with a damp cloth. Do not immerse the pump in water.
- If transferring different types of liquids, ensure the pump is flushed appropriately to prevent contamination.
- Store the pump in a dry, clean environment when not in use.
6.1. Product Disassembly Drawing
For advanced maintenance or part replacement, refer to the disassembly diagram and component list below.
| No. | Component | No. | Component |
|---|---|---|---|
| 1 | Screw | 2 | Gear cover |
| 3 | Sealing ring | 4 | Copper cast gear |
| 5 | Shaft | 6 | Key |
| 7 | Copper cast joint | 8 | Pump head |
| 9 | Oil seal | 10 | All-copper motor |
| 11 | Iron base | 12 | Rubber foot |
7. Troubleshooting
If the pump is not operating as expected, consider the following common issues:
- No Power: Check electrical connections, ensure the power source matches the pump's voltage (12V or 24V), and verify the power supply is active.
- No Flow/Weak Flow: Ensure the inlet hose is fully submerged in the liquid and not blocked. Check for kinks or blockages in both inlet and outlet hoses. Verify the pump head and gears are clear of debris.
- Leaks: Inspect all pipe connections for tightness. Check for cracks or damage to hoses or pump housing.
- Unusual Noise: This could indicate a blockage, worn gears, or motor issues. Disconnect power immediately and inspect the pump.
If problems persist after checking these points, consult a qualified technician or contact customer support.
8. User Tips
No specific user tips were available from reviews or Q&A for this product at this time.
9. Warranty and Support
For warranty information or technical support, please refer to the documentation provided with your purchase or contact the seller directly. Keep your purchase receipt as proof of purchase.
A user manual in PDF format may also be available for download from the seller's product page or support section.