1. General Information
The MYoslim Ems Body Sculpt Machine utilizes advanced HI-EMT technology, employing high-energy focused electromagnetic waves (HI-EMT) designed to induce powerful muscle contractions, thereby promoting muscle growth and reshaping the internal structure of muscles. Additionally, it claims to trigger significant fat breakdown through intense muscle contractions, causing fatty acids to be released from triglycerides and metabolized by the body over several weeks.
1.1 Indications for Use
- Improvement of abdominal tone, strengthening of the abdominal muscles, development of a fitter abdomen.
- Strengthening, toning, and firming of buttocks, thighs, and calves.
- Improvement of muscle tone and firmness, for strengthening muscles in arms.
1.2 Operating Environment
The operating environment of the EMS Body Sculpt instrument series is crucial to ensuring the effectiveness and safety of the device.
- Clean and Hygienic Environment: The operating environment should be clean and hygienic to prevent any external contamination or bacterial infections. Regular cleaning and disinfection of the equipment and its accessories are essential.
- Appropriate Temperature and Humidity: Ensure that the operating environment's temperature and humidity are within the appropriate range specified by the device manufacturer. Extreme temperatures or excessive dryness/humidity may impact the device's performance.
- Adequate Lighting: Provide sufficient lighting to ensure that operators can clearly see and operate the equipment correctly. This is especially important for conducting precise beauty procedures.
- Good Ventilation: The area where the equipment is operated should have adequate ventilation to ensure air circulation and prevent the accumulation of any harmful gases.
- Safety Measures: The operating environment should have appropriate safety measures, including fire extinguishers and first aid equipment, to address emergencies. Operators should be familiar with the equipment's safety procedures and know how to handle emergency situations.
- Avoidance of Interference Sources: The operating environment for beauty equipment should be kept away from any electromagnetic fields or other devices that could potentially cause interference, ensuring the normal operation of the equipment.
- Operator Training: All operators using beauty equipment should undergo proper training to understand the correct usage and safety procedures of the equipment.
1.3 Patient Profile
This machine is suitable for patients who are seeking healthy weight loss, who have no physical diseases, and who do not have metal substances in their bodies. Please note that this machine is only suitable for adults.
1.4 Description of the Device
The EMS Body Sculpt enables a simple and effective treatment process that you can easily perform by adjusting the digital energy selection treatment plan or diagnostic procedure. Additionally, any treatment parameter can be manually adjusted by simply touching the screen. You can also create precise and effective treatment plans by configuring the age group and gender of the person being treated within the machine.
1.5 Contraindications
The MYoslim Ems Body Sculpt Machine is not suitable for individuals with:
- Wounds on the skin (or avoiding wounds when using).
- Heart disease (such as those with arrhythmias), especially those with pacemakers.
- Cancer.
- Infectious diseases.
- Pregnancy, lactation, or during menstrual period.
- Major surgery patients, diabetic patients.
- Any metal in the body.
- Cerebrovascular disease (stroke patients).
1.6 Possible Side Effects
These effects may include but are not limited to:
- Muscle soreness.
- Reduction in muscle fat.
- Temporary muscle spasms.
- Transient joint or muscle tendon pain.
- Localized redness or skin flushing.
2. Safety Precautions and Warnings
Precautions before use:
- Do not use when feeling full, at least one hour after meals.
- Before using the instrument, remove any metal jewelry you are wearing.
- Before starting the operation, touch the probe vertically to the skin, then turn on the switch of the main unit and adjust the intensity of the operation mode.
- Set the intensity to the lowest level, and then increase the intensity sequentially according to the user's skin tolerance.
- It is forbidden to eat or drink during the operation, and try to eat after one hour after the operation.
3. Device and Accessories
3.1 Front and Rear Panel of the Main Unit
Front View:

The front panel features a display screen and two EMS handles. Note: The handle can only be used by the original machine and cannot be used interchangeably.
Rear View:

The rear panel includes connections for the handles, the power plug, and the fuse.
3.2 Handle Types
The machine supports various handle configurations, including optional accessories like cushions.

Various handle types are available, including standard handles and an optional cushion for specific treatments.
3.3 List of Accessories
| Serial | Name | Quantity | Picture |
|---|---|---|---|
| 1 | Host | 1 set | ![]() |
| 2 | Handle | 2 | ![]() |
| Handle | 2 | ![]() | |
| Cushion (optional accessories) | 1 | ![]() | |
| 3 | Belt | 7*100CM*2, 5*60CM*2 | ![]() |
| 4 | Power cable | 1 | ![]() |
| 5 | Electronic manual | 1 copy | ![]() |
4. Device Installation (Setup)
4.1 Install the Handle Bracket

Use a screwdriver to install the handle brackets on both sides of the machine. Ensure installation is successful.
4.2 Handle Film Application

Stick the black film to the working part of the handle.
4.3 Installing the Handle

Align the hole and fasten the clip, then lock the key ring.
4.4 Connect Power

Connect one end of the power cord to the machine and the other end to the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the same socket.
4.5 Press the Back Switch

Press the switch on the back of the machine to turn it on (light on) or off (light off).
5. Operating Instructions
5.1 Handle Exchange
The handle must be calibrated every time it is installed or replaced.
Warning: When replacing the handle, you must turn off the power of the machine. The handle cannot be replaced when the machine is powered on.
5.2 Device Start Up/Shut Down
- Connect one end of the power cord to the machine and plug the other end into the socket. Plug the power cord directly into the main socket. Do not connect multiple machines to the socket.
- Move the manual switch on the rear panel to the "o" position.
- Press the button on the front panel.
- When the treatment is finished, press and hold the power button to turn off the machine.
5.3 Navigation Controls & Setting the Therapy
Pre-treatment regimen can be modified via on-screen controls. The treatment interface displays the following items and functions:

The touch-controlled display allows for easy navigation and adjustment of therapy parameters.
Mode 1 Operation:
- Click 'Mode 1' on the screen.
- The operation interface of Mode 1 is displayed. Ensure the handle is removed from its frame and fixed to the customer's body part using the belt. The frequency for Mode 1 is 5-60Hz.
- Adjust the handle operation time according to customer needs.
- Click the start/stop button to proceed to the next step.

Adjusting time and intensity for Mode 1 therapy.
Note: Adjust the corresponding intensity according to different customer needs to start the operation. If the customer requests to pause, you can click start/pause. The work button suspends the work, and you can directly click the back button to return after the work is completed.
Mode 2 Operation:
- Click 'Mode 2' on the screen.
- The operation interface of Mode 2 is displayed. Ensure the handle is removed from its frame and fixed to the customer's body part using the belt. The frequency for Mode 2 is 30-100Hz.
- Adjust the handle operation time according to customer needs.
- Click the start/stop button to proceed to the next step.

Adjusting time and intensity for Mode 2 therapy, which features 3 different periods of frequency.
5.4 Unit Settings
The device offers various unit settings for customization:
- Language Settings: Adjust the display language. The machine supports English, Spanish, Portuguese, French, Russian, Chinese, Japanese, and Korean.
- Sound Adjustment: Control the device's sound output.
- Brightness Adjustment: Modify screen brightness for optimal visibility.
- Set Date Time: Configure the current date and time.
- System Adjustment: Access system-level settings.
- Technician: Access technician-specific settings (password protected).

Screenshots of the diverse touch screen settings for multilingualism, operating interface, home, customer information, and date.
5.5 Preparing for Therapy & Placing the Handle
Before starting a therapy session, ensure the following steps are taken:
- Communicate with patients to understand their needs and comfort levels.
- Ensure the patient is in good health and has no contraindications.
- Ensure the patient is well-hydrated.
- The patient should wear appropriate, comfortable clothing.
- Avoid eating large quantities before the session.
- Familiarize yourself with the treatment process.
- Avoid drinking alcohol before the session.
Handle Placement:

Illustrations demonstrating how to correctly place the handles on different target areas such as the belly, buttocks, arms, thighs, calves, and for pelvic floor training.
Please operate according to the controller model you purchased and follow the manufacturer's official documentation to ensure the best experience. If you have any questions, please contact customer service for support.
6. Maintenance
6.1 Daily Inspection
Managers must regularly inspect instruments and components. Check whether the power socket has a reliable connection to the ground. Check whether the power cord of the instrument is damaged before use, and stop using the instrument if it is damaged.
6.2 Cleaning of the Surface of the Device
The logo of the machine is painted by silk screen printing process. The rest of the parts are painted with a spray painting technique. Please use cotton paper towels or ordinary toilet paper moistened with water to wipe clean; do not use alcohol-based detergents.
6.3 Cleaning of Accessories that Come into Contact with Patient
The parts that come into contact with the skin should be cleaned and disinfected with 75% alcohol before and after use. Do not soak directly in alcohol-based detergent as a whole; wipe with pure cotton material.
6.4 Transport and Storage
Storage: The instrument should be stored in the original packaging box, placed in a well-ventilated room. The packaging box should be padded. The ambient temperature should be -10°C to 40°C, the relative humidity should not be greater than 93%, and it is not allowed to be placed in harmful gases, around flammable, explosive substances, and corrosive gases.
Transportation: The instrument under the packaging condition is suitable for road, railway, air, and water transportation. During loading, unloading, and transportation, it should prevent severe vibration and shock, and should not be affected by moisture, and should not be mixed with flammable and corrosive substances. The specific requirements are specified in the order contract.
7. Troubleshooting
Common Faults and Troubleshooting Methods
| Fault Phenomenon | Causes | Exclusions and Workarounds |
|---|---|---|
| Device not working | The power plug is not inserted into the socket Power switch not on Power fuse failure | Check the power Check the power switch Replace the fuse |
| Handle not working | Check the handle for loose connection | Reseat the handle |
8. Specifications
8.1 Technical Parameters
| Name | Value |
|---|---|
| Model | E-04 |
| Max Frequency | 200HZ |
| Intensity | 15 Tesla |
| Power | 6500W |
| Handles | Per 1 to 4 Handles + 1 Seat-type Working Handle (Optional) |
| Feature | Fat Burning & Muscle Building & Pelvic Floor Muscle Repair |
| Cooling System | Air Cooling |
| Voltage | 100~230V Wide Voltage |
| Screen size | 8.0 inches |
| Machine color | Black |
| Material | ABS |
| Certification | CE, RoHS |
8.2 EMS vs. Other Technologies
| Feature | EMS (HIEMT) | Traditional RF, Laser, Cryolipolysis |
|---|---|---|
| Primary Action | Muscle Building + Fat Reduction | Primarily Fat Reduction or Primarily Skin Tightening |
| Principle | Induces supramaximal muscle contractions | Heats, cools, or destroys fat cells |
| Result | Improves muscle shape and reduces fat thickness | Mainly reduces fat or tightens skin; does not build muscle |
8.3 Radiated Electromagnetic Field Immunity Test
Port: Enclosure
Basic Standard: IEC 61000-4-3:2020
Test Level: 30V/m with 80% AM. 1kHz Modulation.
Standard require: A
Tester: Sam Liu
Temperature: 25°C
Humidity: 54%
Test Equipment
| Description | Manufacturer | Model | Identifier | Cal. Date | Cal. Due |
|---|---|---|---|---|---|
| Signal Generator | IFA | 2023B | N/A | 15/03/2022 | 14/03/2023 |
| Power Amplifier | AR | 150W1000 | N/A | 15/03/2022 | 14/03/2023 |
| Power Antenna | AR | 25S1G4A | N/A | 15/03/2022 | 14/03/2023 |
Block Diagram of Test Setup

Diagram illustrating the arrangement of equipment for the electromagnetic field immunity test.
9. Warranty and Support
9.1 Warranty Card Information
The machine can be replaced with a new one within 7 days from the date of purchase (with the receipt) with the intact appearance. The main machine is guaranteed for one year (except for fragile parts, and other non-warranty scope or expired warranty period). Also, it can be responsible for maintenance and update, and the maintenance fee needs to be charged appropriately. If the instrument is broken and needs to be sent back for repair, the buyer shall bear the return shipping out cost within six months from the date of purchase, and the seller shall bear the shipping in cost; the buyer shall bear all the shipping costs for more than half a year.
Free warranty service is not provided for the following user's failures caused by personal reasons:
- Faults caused by unauthorized disassembly and modification of this product.
- Faults caused by accidental fall.
- Failure caused by lack of reasonable maintenance.
- Failure to operate according to the correct instructions in the instruction manual.
9.2 Manufacturer
Guangzhou Xinwei Electronic Technology Co., Ltd.
9.3 After-Sales Service & Support
- Local Repair Centers: Dual repair centers in Mexico and Europe offer faster overseas local after-sales service, reducing international shipping costs and repair times.
- Professional Technical Team: Experienced engineers provide online diagnostics and local repair support.
- Warranty: The machine comes with a one-year warranty.
- Support: Video technical support and online support are available.
10. User Tips
- The machine is beginner-friendly and easy to use, making it suitable for home use.
- The machine's sensitivity is high, allowing for real-time parameter adjustments based on customer feedback.
- For shaping, expect to see muscle tightening in 2-4 weeks (3-5 times a week).
- For fat burning, cooperate with diet; waist circumference may reduce 3-5cm in 1-2 months.
- For muscle building, combine with strength training for more significant results.
- Customer service is responsive and provides professional advice.
11. Frequently Asked Questions (FAQ)
Q: How long does it take to see the effect?
A: It varies from person to person, usually:
- Shaping: 2~4 weeks (3~5 times a week) to see muscle tightening.
- Fat burning: Need to cooperate with diet, waist circumference may reduce 3~5cm in 1~2 months.
- Muscle building: It is recommended to combine with strength training for more significant results.
Q: Can this machine replace traditional fitness?
A: It cannot completely replace, but it is suitable for:
- People who don’t have time to go to the gym.
- Muscle activation during rehabilitation.
- Breakthrough of the plateau period for fitness people.
Q: Is EMS harmful to the body?
A: Safety premise:
- Healthy people: It can be used without contraindications such as pacemakers and epilepsy.
- Pregnant women/menstrual period: It is not recommended to use it in the abdomen.
- Pain: It may be slightly stinging when used for the first time, and it is necessary to adapt from low intensity.
Q: Who should not use it?
A: Taboo groups:
- Pregnant women, heart patients.
- Skin damage or inflammation sites.
- Painful patients with malignant tumors and thrombosis.
Q: How long should I use it each time? How often?
A: Recommendations:
- Beginners: 15-20 minutes/time, 3 times a week.
- Advanced: 30 minutes/time, 5 times a week.
- Avoid overuse leading to muscle fatigue.
Q: Do I need to apply gel? How to clean?
A: It does not need to be used with conductive gel. Wipe the electrode with a damp cloth after use to avoid alcohol corrosion.Q: Are there any additional charges for delivery?