Y&H 1800W 3000W Hybrid Solar Inverter

Contents

Y&H Hybrid Solar Inverter User Manual

Models: 1.8KW-12V BAT, 3KW-24V BAT

1. Safety Instructions

⚠️ WARNING: This chapter contains important safety and operating instructions. Read and keep this manual for future reference.

  1. Before using the unit, read all instructions and cautionary markings on the unit, the batteries and all appropriate sections of this manual.
  2. CAUTION --To reduce risk of injury, charge only deep-cycle lead acid type rechargeable batteries. Other types of batteries may burst, causing personal injury and damage.
  3. Do not disassemble the unit. Take it to a qualified service center when service or repair is required. Incorrect re-assembly may result in a risk of electric shock or fire.
  4. To reduce risk of electric shock, disconnect all wirings before attempting any maintenance or cleaning. Turning off the unit will not reduce this risk.
  5. CAUTION - Only qualified personnel can install this device with battery.
  6. NEVER charge a frozen battery.
  7. For optimum operation of this inverter/charger, please follow required spec to select appropriate cable size. It's very important to correctly operate this inverter/charger.
  8. Be very cautious when working with metal tools on or around batteries. A potential risk exists to drop a tool to spark or short circuit batteries or other electrical parts and could cause an explosion.
  9. Please strictly follow installation procedure when you want to disconnect AC or DC terminals. Please refer to INSTALLATION section of this manual for the details.
  10. GROUNDING INSTRUCTIONS -This inverter/charger should be connected to a permanent grounded wiring system. Be sure to comply with local requirements and regulation to install this inverter.
  11. NEVER cause AC output and DC input short circuited. Do NOT connect to the mains when DC input short circuits.
  12. Warning!! Only qualified service persons are able to service this device. If errors still persist after following troubleshooting table, please send this inverter/charger back to local dealer or service center for maintenance.

2. Product Overview

The Y&H Hybrid Solar Inverter is a multi-function inverter/charger designed to provide uninterruptible power support. It integrates an inverter, solar charger, and battery charger into a compact unit. The comprehensive LCD display and user-configurable buttons allow for easy operation, including setting battery charging current, AC/solar charger priority, and acceptable input voltage ranges.

Y&H Hybrid Solar Inverter showing 3000W 24V, DC 24V Battery Voltage, 55-450Vdc Max PV Input, and MPPT 80A Charging Current.
Figure 1: Y&H Hybrid Solar Inverter (3000W 24V model)

2.1. Key Features

  • Pure sine wave inverter
  • Configurable input voltage range for home appliances and personal computers via LCD setting
  • Configurable battery charging current based on applications via LCD setting
  • Configurable AC/Solar Charger priority via LCD setting
  • Compatible with mains voltage or generator power
  • Auto restart while AC is recovering
  • Overload/ Over temperature/ short circuit protection
  • Smart battery charger design for optimized battery performance
  • Cold start function
  • WIFI (Optional)
  • Can connect to lithium battery
  • Intelligent fan speed adjustment
Collage of inverter features including pure sine wave technology, intelligent temperature control, multiple protection, and LCD screen with LED indicators.
Figure 2: Inverter Feature Highlights

2.2. Basic System Architecture

The inverter supports various configurations, including connection to solar power, generators, utility grids, battery packs, and home appliances. It is designed to power all kinds of appliances in home or office environments.

Diagram showing a hybrid power system with solar panels, generator/utility, inverter, external battery packs, and home appliances.
Figure 3: Hybrid Power System Diagram
Image showing seamless connection of multiple battery types including FLD, LI, SLD, AGM, GEL with the inverter. Battery BMS must be PylonTech.
Figure 4: Multiple Battery Compatibility
Image showing the inverter connected to various home appliances like a microwave, washing machine, and refrigerator, demonstrating its ability to power daily needs.
Figure 5: Powering Home Appliances

2.3. Wi-Fi Communication

The inverter supports Wi-Fi communication, allowing you to monitor its operation remotely via a mobile application.

A person using a smartphone to check the inverter's status via Wi-Fi communication.
Figure 6: Wi-Fi Communication for Remote Monitoring

3. Installation

3.1. Unpacking and Inspection

Before installation, inspect the unit for any damage. The package should contain:

  • The inverter unit x 1
  • User manual x 1

3.2. Mounting the Unit

Consider the following points for selecting the installation location:

  • Do not mount the inverter on flammable construction materials.
  • Mount on a solid surface.
  • Install this inverter at eye level to easily read the LCD display.
  • Allow approximately 20 cm clearance on the sides and 50 cm above and below for proper air circulation.
  • The ambient temperature should be between 0°C and 55°C for optimal operation.
  • The recommended installation position is adhered to the wall vertically.
  • Keep other objects clear to ensure sufficient heat dissipation and space for wiring.

⚠️ WARNING: SUITABLE FOR MOUNTING ON CONCRETE OR OTHER NON-COMBUSTIBLE SURFACE ONLY.

Install the unit by screwing two screws. M4 or M5 screws are recommended.

3.3. Wiring Connections

Before connecting any wires, remove the bottom cover by unscrewing two screws. All wiring must be performed by qualified personnel.

Play video
Watch video online
Video 1: Product Wiring and Setup Demonstration. This video shows the step-by-step process of connecting the battery, AC input, AC output, and PV input to the inverter, followed by initial power-up and basic LCD settings for lithium batteries.

3.3.1. Battery Connection

⚠️ WARNING: Shock Hazard! Installation must be performed with care due to high battery voltage in series.

⚠️ CAUTION: Before making the final DC connection or closing DC breaker/disconnector, be sure positive (+) must be connected to positive (+) and negative (-) must be connected to negative (-).

It is important to install a separate DC over-current protector or disconnect device between the battery and inverter. Use appropriate cable sizes as recommended below:

ModelWire SizeCable (mm²)Torque Value (max)
2.2KVA 12V1 x 4AWG222 Nm
3.2KVA 24V1 x 6AWG142 Nm

Steps:

  1. Remove insulation sleeve 18 mm for positive and negative conductors.
  2. Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Connect all battery packs as shown in the diagram below.
  4. Insert the battery wires flatly into battery connectors of inverter and make sure the bolts are tightened with a torque of 2 Nm in a clockwise direction. Ensure correct polarity.

3.3.2. AC Input/Output Connection

⚠️ CAUTION: Install a separate AC breaker between the inverter and AC input power source. Recommended AC breaker is 20A for 2.2KVA and 32A for 3.2KVA. Do NOT mis-connect input and output connectors.

Use appropriate cable sizes as recommended below:

ModelGaugeTorque Value
2.2KVA 12V14 AWG0.5~0.6Nm
3.2KVA 24V12 AWG1.2 Nm

Steps:

  1. Before making AC input/output connection, open DC protector or disconnector first.
  2. Remove insulation sleeve 10mm for five conductors. Shorten phase L and neutral conductor N by 3 mm.
  3. Insert AC input wires according to polarities (L: brown/black, N: blue, PE: yellow-green) and tighten terminal screws.
  4. Then, insert AC output wires according to polarities and tighten terminal screws.

3.3.3. PV Connection

⚠️ CAUTION: Install a separate DC circuit breaker between the inverter and PV modules.

Use appropriate cable sizes as recommended below:

ModelWire SizeTorque Value (max)
2.2KVA 12V1x16AWG1.2 Nm
3.2KVA 24V1x16AWG1.2 Nm

PV Module Selection:

When selecting PV modules, consider the following:

  • Open circuit Voltage (Voc) of PV modules must not exceed the Max. PV array open circuit voltage of the inverter (450Vdc).
  • PV Array MPPT Voltage Range: 90Vdc-430Vdc.

Steps:

  1. Remove insulation sleeve 10 mm for positive and negative conductors.
  2. Suggest to put bootlace ferrules on the end of positive and negative wires with a proper crimping tool.
  3. Check correct polarity of wire connection from PV modules and PV input connectors. Connect positive (+) to positive (+) and negative (-) to negative (-).

3.4. Final Assembly

After connecting all wirings, replace the bottom cover by screwing in four screws.

4. Operation

4.1. Power ON/OFF

Once the unit is properly installed and batteries are connected, simply press the On/Off switch (located on the bottom of the case) to turn on the unit.

4.2. Operation and Display Panel

The front panel features an LCD display, three indicators (AC/INV, CHG, FAULT), and four function keys (ESC, UP, DOWN, ENTER) to show operating status and input/output power information.

LED IndicatorColorStatusMessages
AC/INVGreenSolid OnOutput is powered by utility in Line mode.
FlashingOutput is powered by battery or PV in battery mode.
CHGGreenSolid OnBattery is fully charged.
FlashingBattery is charging.
FAULTRedSolid OnFault occurs in the inverter.
FlashingWarning condition occurs in the inverter.
Function KeyDescription
ESCTo exit setting mode
UPTo go to previous selection
DOWNTo go to next selection
ENTERTo confirm the selection in setting mode or enter setting mode

4.3. LCD Display Icons

The LCD display provides detailed information about input source, configuration, output, and battery status. Key icons include:

  • AC: Indicates AC input.
  • PV: Indicates PV input.
  • INPUT/BATT: Displays input voltage, frequency, PV voltage, charger current, charger power, battery voltage.
  • 88: Indicates setting programs.
  • 88A ERROR: Indicates warning and fault codes.
  • OUTPUT/BATT/LOAD: Displays output voltage, frequency, load percent, load in VA/Watt, and discharging current.
  • CHARGING: Indicates battery level (0-24%, 25-49%, 50-74%, 75-100%) and charging status.

4.4. LCD Settings for Lithium Batteries

To enter setting mode, press and hold the ENTER button for 3 seconds. Use UP/DOWN buttons to select programs and ENTER to confirm. For lithium battery settings, specific options need to be configured based on your battery's specifications (e.g., LiFePO4 battery).

Important Lithium Battery Settings:

  1. Program 05 (Battery Type): Set to 'USE' (User-Defined) for lithium batteries. This allows custom voltage settings.
  2. Program 26 (Bulk Charging Voltage): Set according to the lithium battery's charging cutoff voltage (e.g., 14.6V for a 12.8V LiFePO4 battery).
  3. Program 27 (Floating Charging Voltage): Set according to the lithium battery's charging cutoff voltage (e.g., 14.6V for a 12.8V LiFePO4 battery).
  4. Program 29 (Low DC Cut-off Voltage): Set according to the lithium battery's discharge cutoff voltage (e.g., 9.5V for a 12.8V LiFePO4 battery).
  5. Program 01 (Output Source Priority): Set to 'SBU' (Solar Battery Utility) for PV power maximization.
  6. Program 12 (Battery Voltage for Utility Power Supply): Set to the battery voltage at which the utility power supply should automatically take over and charge the battery (e.g., 12.8V for a 12.8V LiFePO4 battery).
  7. Program 13 (Battery Voltage for Mains Power Supply Stop): Set to the battery voltage at which the mains power supply stops and switches to battery power supply (e.g., 13.5V for a 12.8V LiFePO4 battery).
  8. Program 16 (Charger Source Priority): Set to 'C50' (Solar Priority Charging) to prioritize solar charging.

4.5. Operating Mode Description

The inverter operates in various modes, each with specific charging and power supply behaviors:

Operation ModeDescriptionCharging Source
Standby / Power SavingInverter is off, but can charge batteries.Utility and PV energy, or Utility only, or PV only.
Line ModeUnit provides output power from mains and charges battery.Utility and PV energy, or Utility only.
Battery ModeUnit provides output power from battery and PV power.PV energy only.
Fault ModeErrors due to internal circuit, over temperature, etc.PV energy and utility can charge batteries.

5. Maintenance

5.1. Anti-Dust Kit Clearance and Maintenance

Every inverter is pre-installed with an anti-dust kit. This kit helps maintain internal temperature and protects the inverter from dust in harsh environments.

Steps for Cleaning:

  1. Remove the screws securing the dustproof case.
  2. Carefully remove the dustproof case and take out the air filter foam.
  3. Clean the air filter foam and dustproof case.
  4. Re-assemble the dust kit back to the inverter.

NOTICE: The anti-dust kit should be cleaned from dust every one month.

5.2. Battery Equalization

The equalization function helps reverse the buildup of negative chemical effects like stratification and removes sulfate crystals from battery plates, which can reduce battery capacity. It is recommended to equalize the battery periodically.

How to Apply Equalization Function:

  1. Enable battery equalization in LCD setting program 33.
  2. Ensure program 05 is set to user-defined or flooded mode.
  3. Ensure program 33 is enabled.
  4. Set equalization parameters in programs 34 to 37 based on your battery requirements.
  5. Activate equalization immediately in program 39.

6. Troubleshooting

Refer to the table below for common problems and their solutions:

ProblemLCD/LED/BuzzerExplanation / Possible CauseWhat to do
Unit shuts down automatically during startup process.LCD/LEDs and buzzer active for 3 seconds then off.Battery voltage is too low (<1.91V/Cell)1. Re-charge battery.
2. Replace battery.
No response after power on.No indication.1. Battery voltage is far too low (<1.4V/Cell)
2. Internal fuse tripped.
1. Contact repair center for replacing fuse.
2. Re-charge battery.
3. Replace battery.
Input voltage is 0 on LCD, green LED flashing.Input protector is trippedCheck if AC breaker is tripped and AC wiring is connected well.
Mains exist but unit works in battery mode.Green LED is flashing.Insufficient quality of AC power (Shore or Generator)1. Check if AC wires are too thin and/or too long.
2. Check if generator (if applied) is working well or if input voltage range setting is correct.
Unit turned on, internal relay switches on/off repeatedly.LCD display and LEDs are flashingBattery is disconnected.Check if battery wires are connected well.
Fault code 07Overload error. Inverter is overload 110% and time is up.Reduce the connected load by switching off some equipment.
Fault code 05Output short circuited.Check if wiring is connected well and remove abnormal load.
Fault code 02Temperature of internal converter component is over 120°C.Check whether air flow is blocked or ambient temperature is too high.
Buzzer beeps continuously, red LED on.Fault code 03Battery is over-charged.Return to repair center.
The battery voltage is too high.Check if spec and quantity of batteries meet requirements.
Fault code 01Fan faultReplace the fan.
Fault code 06/58Output abnormal (Inverter voltage below 190Vac or higher than 260Vac)1. Reduce connected load.
2. Return to repair center.
Fault code 08/09/53/57Internal components failed.Return to repair center.
Fault code 51Over current or surge.Restart unit, if error persists, return to repair center.
Fault code 52Bus voltage is too low.
Fault code 55Output voltage is unbalanced.

7. Specifications

7.1. Line Mode Specifications

INVERTER MODEL2.2KVA-12V3.2KVA-24V
Input Voltage WaveformSinusoidal (utility or generator)
Nominal Input Voltage230Vac
Low Loss Voltage170Vac±7V (UPS); 90Vac±7V (Appliances)
Low Loss Return Voltage180Vac±7V (UPS); 100Vac±7V (Appliances)
High Loss Voltage280Vac±7V
High Loss Return Voltage270Vac±7V
Max AC Input Voltage300Vac
Nominal Input Frequency50Hz / 60Hz (Auto detection)
Low Loss Frequency40±1Hz
Low Loss Return Frequency42±1Hz
High Loss Frequency65±1Hz
High Loss Return Frequency63±1Hz
Output Short Circuit ProtectionCircuit Breaker
Efficiency (Line Mode)>95% (Rated R load, battery full charged)
Transfer Time10ms typical (UPS); 20ms typical (Appliances)

7.2. Inverter Mode Specifications

INVERTER MODEL2.2KVA-12V3.2KVA-24V
Rated Output Power2200VA/1800W3200VA/3000W
Output Voltage WaveformPure Sine Wave
Output Voltage Regulation230Vac±5%
Output Frequency50Hz
Peak Efficiency94%
Overload Protection5s@ >150% load; 10s@ 110% ~ 150% load
Surge Capacity2* rated power for 5 seconds
Nominal DC Input Voltage12Vdc24Vdc
Cold Start Voltage11.5Vdc23.0Vdc
Low DC Warning Voltage @ load < 50%11.0Vdc22.0Vdc
Low DC Warning Voltage @ load > 50%10.5Vdc21.0Vdc
Low DC Warning Return Voltage @ load < 50%11.5Vdc22.5Vdc
Low DC Warning Return Voltage @ load > 50%11.0Vdc22.0Vdc
Low DC Cut-off Voltage @ load < 50%10.2Vdc20.5Vdc
Low DC Cut-off Voltage @ load > 50%9.6Vdc20.0Vdc
High DC Recovery Voltage14.5Vdc29Vdc
High DC Cut-off Voltage15.5Vdc31Vdc
No Load Power Consumption<25W<35W

7.3. Charge Mode Specifications

INVERTER MODEL2.2KVA-12V3.2KVA-24V
Charging Algorithm3-Step
AC Charging Current (Max)60 Amp (230Vac)60Amp (230Vac)
Bulk Charging Voltage (Flooded Battery)14.629.2
Bulk Charging Voltage (AGM / Gel Battery)14.128.2
Floating Charging Voltage13.5Vdc27Vdc
Max. PV Array Power2000W3000W
Nominal PV Voltage240Vdc
PV Array MPPT Voltage Range55~430Vdc
Max. PV Array Open Circuit Voltage450Vdc
Max Charging Current (AC charger plus solar charger)80Amp

7.4. General Specifications

INVERTER MODEL2.2KVA-12V3.2KVA-24V
Safety CertificationCE
Operating Temperature Range-10°C to 50°C
Storage temperature-15°C ~ 60°C
Humidity5% to 95% Relative Humidity (Non-condensing)
Dimension (D*W*H), mm348*282*105mm
Net Weight, kg5.05.5

8. User Tips

  • This inverter is compatible with LiFePO4 batteries. Ensure correct settings (Program 05, 26, 27, 29) are applied for optimal performance and battery longevity.
  • The hybrid inverter can function without a battery, relying solely on solar panels, depending on the specific operating mode configuration.

9. Warranty and Support

For any issues not covered in the troubleshooting section or for warranty claims, please contact your local dealer or service center. Only qualified personnel should attempt repairs.

A detailed user manual in PDF format is available for download: Download User Manual (PDF)

Documents and downloads

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.