1. Product Overview
The Gaqqee DTS6619 is a high-quality, reliable, and accurate 3-phase 4-wire digital electric energy meter designed for monitoring power consumption. It features good resistance to electromagnetic interference, low power consumption, high accuracy, high overload capacity, high stability, and an ultra-long lifespan. Its compact and lightweight design allows for standard DIN rail installation.
A large display screen with backlight provides a clear and intuitive view of energy data, including KWh, Voltage, Current, Power, Frequency, and Power Factor.

Figure 1: Front view of the DTS6619 Energy Meter with input and output terminals labeled.

Figure 2: Key features of the DTS6619 Energy Meter, including its multifunctional capabilities and high accuracy.
2. Specifications
2.1 Technical Parameters
| Parameter | Value |
|---|---|
| Reference Voltage | 3*127/220 V, 3*230/400 V |
| Reference Current | 3*10 (100A) |
| Accuracy Level | 1.0 |
| Rated Frequency | 50Hz |
| Power Consumption | ≤2W, 10VA |
| Working Temperature | -20°C to 55°C |
| Storage Temperature | -25°C to 70°C |
| Display Type | Digital Only |
| Phase | Three Phase |
| DIY Supplies | Electrical |
| Origin | Mainland China |
2.2 Physical Dimensions

Figure 3: Dimensions of the DTS6619 Energy Meter (Height: 100mm, Width: 76mm, Depth: 65mm, DIN rail mounting depth: 35mm).
3. Safety Information
- The electric energy meter should be installed indoors in a ventilated and dry place.
- The bottom plate of the electric energy meter should be fixed on a sturdy, fire-resistant, and vibration-resistant wall.
- In environments with potential pollution or risk of damage to the mechanism, the energy meter should be installed within a protective cabinet.
- Ensure all wiring is performed by a qualified electrician in accordance with local electrical codes and safety standards.
4. Installation
4.1 Mounting
The DTS6619 energy meter is designed for 35mm DIN standard rail type installation. Ensure the mounting location is indoors, ventilated, and dry. Securely mount the meter onto the DIN rail.

Figure 4: The DTS6619 Energy Meter securely mounted on a standard DIN rail.
4.2 Wiring
All wiring must be carried out according to the wiring diagram provided on the end button cover of the energy meter or as shown in the diagram below. It is crucial to use multiple copper wires for connections to prevent poor contact, which could lead to abnormal operation or burning of the energy meter.

Figure 5: Detailed wiring diagram for the 3-phase 4-wire energy meter. Connect L1, L2, L3, and N for both input and output as indicated.
Once the meter is correctly connected to the power grid, the power indicator light on the meter should be constantly on, indicating proper power supply.
5. Operation
The DTS6619 energy meter features a clear LCD screen with backlight for easy reading, even in low-light conditions. The meter displays various energy parameters.
5.1 Display Indicators

Figure 6: Labeled components of the DTS6619 Energy Meter, highlighting the LCD, indicators, and terminals.
- LCD Screen with Backlight: Displays energy consumption data and other parameters.
- Pulse Indicator: Flashes to indicate energy consumption.
- L1, L2, L3 Power Indicators: These lights indicate the presence of power on each respective phase. They should be constantly on when the meter is correctly connected to the power grid.
5.2 Reading Data
The meter digitally displays energy consumption in kilowatt-hours (KWh). It can also display real-time values for Voltage, Current, Power, Frequency, and Power Factor, providing a comprehensive overview of your electrical system's performance.
6. Maintenance
The DTS6619 energy meter is designed for durability and minimal maintenance. To ensure optimal performance and longevity:
- Keep the meter clean and free from dust. Use a soft, dry cloth for cleaning.
- Ensure the installation environment remains ventilated and dry, as specified in the safety guidelines.
- The meter features a sealed cover design to prevent dust ingress and tampering, contributing to its long-term accuracy and reliability.
- Regularly inspect wiring terminals for secure connections to prevent poor contact.
7. Troubleshooting
If you encounter issues with your DTS6619 energy meter, consider the following common troubleshooting steps:
- Meter not displaying or power indicator off: Check all input and output wiring connections to ensure they are secure and correctly wired according to the diagram. Verify that power is supplied to the input terminals.
- Inaccurate readings: Ensure all wiring is correct and tight. Verify that the meter is installed in a stable environment free from excessive vibration or electromagnetic interference.
- Flickering display: Check for stable power supply and secure connections.
For persistent issues, consult a qualified electrician or contact customer support.
8. User Tips
No specific user tips were found in the provided data (reviews or Q&A). However, general best practices for energy meters include:
- Always ensure the meter is installed in a location that is easily accessible for reading but protected from environmental factors.
- Keep a record of your energy readings over time to track consumption patterns and identify potential energy savings.
9. Warranty and Support
For detailed information regarding the product's warranty, please refer to the official documentation or contact the seller directly.
An additional user manual in PDF format is available for download: View User Manual (PDF)