1. Introduction
Thank you for choosing the Mastfuyi FY368 Digital Clamp Meter. This high-precision ammeter is designed for professional and DIY electrical testing, offering a wide range of measurement functions including AC/DC voltage, AC/DC current, capacitance, resistance, temperature, frequency, diode, and continuity. It features True RMS for accurate readings, NCV for non-contact voltage detection, live wire checking, data hold, backlight, LED lighting, and an auto power-off function for energy saving. Please read this manual thoroughly before use to ensure safe and effective operation.
2. Safety Information
WARNING: To avoid electric shock or personal injury, please read and understand all safety information before using this product.
- Always adhere to local and national safety codes.
- Do not use the meter if it appears damaged or if the insulation on the test leads is compromised.
- Do not apply more than the rated voltage, as marked on the meter, between the terminals or between any terminal and earth ground.
- Use caution when working with voltages above 30V AC RMS, 42V peak, or 60V DC. Such voltages pose a shock hazard.
- Remove the test leads from the circuit before changing functions or ranges.
- Do not operate the meter with the battery cover open.
- Replace the battery as soon as the low battery indicator appears.
- Always use the correct terminals, function, and range for your measurements.
- Ensure the clamp jaw is fully closed when measuring current.
3. Package Contents
Verify that all items are present and undamaged:
- Mastfuyi FY368 Digital Clamp Meter
- Test Leads (Red and Black)
- Temperature Test Lead
- User Manual (this document and a multi-language PDF)
- Carrying Bag
- Packing Box

4. Product Overview
The Mastfuyi FY368 is a versatile digital clamp meter designed for various electrical measurements. Its compact design and comprehensive features make it suitable for automotive repair, household electrical checks, and professional use.

4.1 Key Functions
The FY368 offers a wide array of measurement capabilities:

- AC/DC Voltage: Measures up to 600V.
- AC/DC Current: Measures up to 60A, including leakage current.
- Capacitance: Measures up to 60mF.
- Resistance: Measures up to 60MΩ.
- Temperature: Measures from -20℃ to 1000℃ (-4°F to 1832°F).
- Frequency: Measures up to 60KHz.
- Diode & Continuity: For testing diodes and circuit continuity.
- NCV (Non-Contact Voltage): Detects AC voltage without direct contact.
- LIVE Wire Check: Identifies live wires.
- True RMS: Provides accurate measurements for non-sinusoidal waveforms.
- Data Hold: Freezes the current reading on the display.
- Backlight & LED Lighting: For working in dimly lit environments.
- Auto Power Off: Conserves battery life (after 10 minutes of inactivity).
5. Setup
5.1 Battery Installation
The FY368 clamp meter comes with batteries included. If replacement is needed:
- Ensure the meter is turned off and all test leads are disconnected.
- Locate the battery compartment on the back of the meter.
- Unscrew the battery compartment cover.
- Insert new batteries, observing correct polarity (+ and -).
- Replace the battery cover and secure it with the screw.
5.2 Connecting Test Leads
For most measurements (voltage, resistance, capacitance, diode, continuity, temperature), you will need to connect the test leads:
- Insert the red test lead into the "VΩCAPHz" input jack.
- Insert the black test lead into the "COM" input jack.
- For temperature measurements, connect the temperature test lead to the appropriate jacks as indicated on the meter.
6. Operating Modes
Turn the rotary dial to select the desired measurement function. Use the 'SEL' button to cycle through sub-functions if available (e.g., AC/DC for current/voltage, or different modes within a single dial position).
6.1 AC/DC Voltage Measurement
Range: 600V
- Turn the rotary dial to the 'V~' (AC Voltage) or 'V=' (DC Voltage) position. The meter may automatically detect AC or DC.
- Connect the red test lead to the positive side of the circuit and the black test lead to the negative side (or neutral/ground for AC).
- Read the voltage value on the display.

6.2 AC/DC Current Measurement (Clamp)
Range: 60A
- Turn the rotary dial to the 'A~' (AC Current) or 'A=' (DC Current) position.
- Open the clamp jaw and enclose only ONE conductor of the circuit.
- Ensure the clamp jaw is fully closed.
- Read the current value on the display.
6.3 Leakage Current Measurement
Leakage current is generally identified as occurring when the value exceeds 0.03A. For three-phase electricity measurement, clamp all three live wires to perform the leakage test.
- Press the 'SEL' button to switch to the AC current measurement mode.
- Without disconnecting the power supply, clamp the neutral and live wires to measure the leakage current in the circuit.
- Read the leakage current value on the display.

6.4 Capacitance Measurement
Range: 60mF
- Turn the rotary dial to the 'CAP' position.
- Ensure the capacitor is fully discharged before testing.
- Connect the test leads across the capacitor terminals.
- Read the capacitance value on the display.

6.5 Resistance Measurement
Range: 60MΩ
- Turn the rotary dial to the 'Ω' position.
- Ensure the circuit is de-energized before measuring resistance.
- Connect the test leads across the component to be measured.
- Read the resistance value on the display.
6.6 Temperature Measurement
Range: -20℃ to 1000℃ (-4°F to 1832°F)
- Turn the rotary dial to the 'TEMP' position.
- Connect the temperature test lead (thermocouple) to the appropriate input jacks.
- Place the tip of the thermocouple on or near the object whose temperature you wish to measure.
- Read the temperature value on the display.
6.7 Frequency Measurement
Range: 60KHz
- Turn the rotary dial to the 'Hz' position.
- Connect the test leads across the circuit where frequency is to be measured.
- Read the frequency value on the display.
6.8 Diode and Continuity Test
- Turn the rotary dial to the 'Diode/Continuity' position. Use the 'SEL' button to switch between modes.
- Diode Test: Connect the red lead to the anode and the black lead to the cathode of the diode. The display will show the forward voltage drop. Reverse the leads to check for open circuit.
- Continuity Test: Connect the test leads across the circuit or component. If continuity exists (resistance below a certain threshold), the buzzer will sound.
6.9 NCV (Non-Contact Voltage) Detection
- Turn the rotary dial to the 'NCV' position.
- Move the top end of the meter close to the AC voltage source.
- The meter will emit an audible beep and the LED indicator will flash when AC voltage is detected.
6.10 LIVE Wire Check
- Turn the rotary dial to the 'LIVE' position.
- Touch the red test lead to the conductor you want to test.
- The meter will indicate if the wire is live.
7. Special Features
- True RMS: Ensures accurate measurements for both sinusoidal and non-sinusoidal AC waveforms.
- Data Hold: Press the 'HOLD' button to freeze the current reading on the display. Press again to release.
- Backlight: Press the backlight button to illuminate the display for better visibility in low-light conditions.
- LED Lighting: The built-in LED flashlight provides illumination for the work area.
- Auto Power Off: The meter automatically turns off after approximately 10 minutes of inactivity to conserve battery life. Press any button or turn the rotary dial to wake it up.
- Intelligent Anti-Burnout: Designed with protection against incorrect operation.
- Large Screen Dual Display: Provides clear and easy-to-read measurements.

8. Maintenance
8.1 Cleaning
Wipe the case with a damp cloth and mild detergent. Do not use abrasives or solvents. Keep the clamp jaw free of dust and debris.
8.2 Battery Replacement
Refer to section 5.1 for battery installation instructions. Replace batteries promptly when the low battery indicator appears to ensure accurate readings and proper operation.
8.3 Storage
If the meter is not to be used for an extended period, remove the batteries to prevent leakage. Store the meter in a cool, dry place, away from direct sunlight and extreme temperatures.
9. Troubleshooting
| Problem | Possible Cause | Solution |
|---|---|---|
| Meter does not turn on | Dead or incorrectly installed batteries | Check battery polarity; replace batteries. |
| No reading or "OL" displayed | Incorrect range, open circuit, or exceeding maximum input | Select appropriate range; check circuit connections; ensure measurement is within meter's limits. |
| Inaccurate readings | Low battery, external interference, or damaged test leads | Replace batteries; move away from strong electromagnetic fields; inspect and replace test leads if damaged. |
| Buzzer not working for continuity | Continuity threshold not met, or meter in diode mode | Ensure resistance is low enough for continuity; press 'SEL' to switch to continuity mode. |
10. Specifications
| Parameter | Value |
|---|---|
| Model Number | FY368 |
| Display Type | Digital Only |
| Max Display | 6000 Counts |
| Measuring Voltage Range | 600V (AC/DC) |
| Measuring Current Range | 60A (AC/DC) |
| Measuring Resistance Range | 60MΩ |
| Measuring Capacitance Range | 60mF |
| Frequency Range | 60KHz |
| Temperature Range | -20~1000℃ (-4°F~1832°F) |
| Operating Temperature | 0-40 ℃ |
| Dimensions | 197x66x30mm |
| Weight | 138g |
| Battery Included | Yes |
| Auto Power Off | Yes (10 minutes) |
| Certification | CE, FCC, RoHS |
11. User Tips
- For current measurements, always ensure the clamp is around a single conductor, not a bundle of wires, to get an accurate reading.
- When measuring capacitance, always discharge the capacitor completely before connecting the meter to avoid damage to the meter or the component.
- Utilize the NCV function as a preliminary safety check to quickly identify live wires before making contact measurements.
- The backlight and LED flashlight are very useful in dark environments, but remember to turn them off when not needed to save battery.