1. Introduction
Thank you for purchasing the HTRC iMAX B6 V2 Professional Balance Charger. This product is a rapid charger equipped with a high-performance microprocessor and specialized operating software. This manual provides comprehensive information on operating procedures and safety guidelines. Please read it thoroughly before use to ensure safe and efficient operation.
The iMAX B6 V2 features an AUTO function for charging and discharging, especially for Lithium batteries, to prevent overcharging and automatically disconnects and alarms upon malfunction. All settings are user-configurable.

Figure 1: HTRC iMAX B6 V2 Balance Charger and accessories.
2. Safety Warnings and Notes
⚠ WARNING: This product can expose you to chemicals including lead, which is known to the State of California to cause cancer and birth defects or other reproductive harm. For more information go to www.P65Warnings.ca.gov.
- Never leave the charger unattended when connected to power. Terminate operation immediately if any malfunction is detected.
- Keep the charger away from dust, damp, rain, heat, direct sunlight, and vibration. Do not drop.
- The allowable input voltage is 11-18V DC.
- Place the charger and battery on a heat-resistant, non-flammable, and non-conductive surface during operation. Keep flammable materials away.
- Ensure the battery specifications match the charger's requirements. Incorrect setup can damage the battery and charger, potentially causing fire or explosion.
- Always connect the charge cable to the charger first, then to the battery. Reverse this sequence when disconnecting.
- Do not connect more than one battery pack to this charger at a time.
- Never attempt to charge or discharge faulty, damaged, or non-rechargeable batteries.
- Do not disassemble the battery pack.
- Lithium battery packs wired in parallel or series require careful attention to voltage balance to prevent fire or explosion. Series charging is recommended for Lithium batteries.
3. Product Overview
The iMAX B6 V2 is a versatile balance charger designed for various battery types. Below is a diagram illustrating its main components and controls.

Figure 2: Front and side view of the iMAX B6 V2 Balance Charger with labeled components.
- LCD Screen: 16-character, 2-line display for program information.
- Temperature Sensor Port: For connecting an optional temperature probe.
- Batt Type/Stop Button: Selects main program, stops current operation.
- Dec/Inc Buttons: Selects sub-program, alters values.
- Start/Enter Button: Resumes or starts operation.
- Balance Lead Sockets (JST-XH ports): For connecting balance leads of multi-cell batteries.
- Output Charge Lead (4mm banana plug): Main battery connection port.
- DC Input 11-18V: Power input for the charger.

Figure 3: Key features of the iMAX B6 V2 Balance Charger.
4. Specifications
Below are the technical specifications for the HTRC iMAX B6 V2 Balance Charger:
| Feature | Specification |
|---|---|
| Operating voltage range | DC 11~18 Volts |
| Max. Charge power | 80 Watts |
| Max. Discharge power | 10 Watts |
| Charge current range | 0.1~6.0 A |
| Discharge current range | 0.1~2.0 A |
| Current drain for balancing Li-Po/Ion/Fe | 300 mA/cell |
| Li-ion/Fe/Polymer cell count | 1~6 cells |
| NiCd/NiMH battery cell count | 1~15 cells |
| Pb battery voltage | 2V~20V (1~10 cells) |
| Temperature sensor port | Yes |
| Built-in balance | Yes |
| Net Weight | 277g (approx.) |
| Dimension (L×W×H) | 133×87×33 mm |
The charger supports a wide range of battery types:

Figure 4: Wide battery type compatibility.
5. Initial Setup and Parameter Configuration
Upon first connection to a DC 11-18V power source, the charger will display default user settings. You can modify these parameters as needed.
5.1. Navigating Menus and Changing Values
- To alter a parameter value, press the "Start/Enter" key until the value blinks.
- Use the "INC" or "DEC" keys to change the value.
- Press "Start/Enter" again to save the new value.
5.2. Lithium Battery Type Selection (LiPo/Lilo/LiFe)
The charger supports LiFe (3.3V), Lilo (3.6V), and LiPo (3.7V) batteries. It is crucial to select the correct battery type to prevent damage or explosion. The charger attempts to automatically recognize the cell count, but for deeply discharged batteries, manual verification may be needed.
- Cell Count Verification: The charger automatically detects cell count. If the detected count is incorrect (e.g., for deeply discharged batteries), you can set a time limit (e.g., 10 minutes) for the processor to verify the cell count.
5.3. NiMH/NiCd Sensitivity (Delta-Peak)
This setting determines the trigger voltage for automatic charge termination for NiMH and NiCd batteries. The range is 5 to 20mV per cell. A higher setting risks overcharging, while a lower setting may cause premature termination. Refer to your battery's technical specifications.
5.4. Temperature Cut-off
An optional feature (requires a temperature probe, not included). When enabled, you can set a maximum temperature. If the battery reaches this temperature during charging, the process will terminate to protect the battery.
5.5. Input Power Low Cut-off
This function monitors the input voltage. If the input voltage drops below the user-set value, the charging process will terminate to protect the input power source.
6. Operating Modes
6.1. Connecting the Charger

Figure 5: Correct connection sequence for the charger.
- Connect the AC cable and adapter to the charger.
- Correctly connect the positive and negative electrodes of the battery to the charger's output.
- Connect the balanced ports (JST-XH) correctly for multi-cell batteries.
WARNING: You must connect the charger in order, otherwise charging will fail.
6.2. Lithium Battery Charging Modes (LiPo/Li-ion/LiFe)
The iMAX B6 V2 offers several modes for Lithium batteries:
- Charge Mode: For charging Li-Po/Ion/Fe batteries without a balance lead. Set the desired current (0.1-6.0A) and voltage (3.7-22.2V). Press and hold "Start/Enter" for 3 seconds to begin. The screen will show real-time status.
- Balance Charge Mode: For balancing the voltage of individual cells in multi-cell Lithium-polymer batteries while charging. Requires connecting the battery's balance lead to the JST-XH ports. The charger monitors and equalizes individual cell voltages.
- Fast Charge Mode: Reduces charging duration by ending the process earlier. The charging current will decrease towards the end. This results in a slightly smaller charging capacity but significantly shorter charging time.
- Storage Mode: Charges or discharges batteries to a specific voltage level (e.g., 3.75V Lilo, 3.85V LiPo, 3.3V LiFe) for long-term storage, protecting the battery's lifespan.
6.3. NiCd/NiMH Battery Charging Modes
- Charge Mode: For NiCd/NiMH batteries. You can set the charge current (0.1-6.0A). In "Auto" mode, set an upper limit to prevent damage. In "Manual" mode, it charges at the set current. Allowable fast charge current: 1C-2C.
- Cycle Mode (Charge/Discharge & Discharge/Charge): Performs 1 to 5 cycles of charge/discharge or discharge/charge to refresh and balance the battery, stimulating its activity. You can set the sequence and number of cycles.
6.4. Pb (Lead-Acid) Battery Charging Mode
This mode is for Pb batteries with nominal voltages from 2V to 20V. Set the charge current (0.1-6.0A) and nominal voltage. The optimum charge current is typically 1/10 of the capacity. Pb batteries cannot be fast-charged. It is recommended to use the CAPACITY CUT OFF feature to protect the battery.
6.5. Discharging Batteries
Discharging helps to clean residual capacity or reduce voltage to a defined level. Set the discharge current (0.1-2.0A) and final voltage. For Lithium batteries, ensure the final discharge voltage is not below the minimum to prevent capacity loss or failure. The charger monitors individual cell voltages during discharge and will terminate if any cell voltage is abnormal.
7. Data Management and Information Display
7.1. Data Store Program
The charger can store up to five battery data sets, including program settings for continuous charging or discharging. This allows you to recall settings without re-entering them.
- Navigate to "PROGRAM SELECT SAVE DATA".
- Select a storage slot (e.g., [01] NiMH).
- Press "Start/Enter" to save the current settings.
7.2. Load Data Program
To load previously saved battery data:
- Navigate to "PROGRAM SELECT LOAD DATA".
- Use "INC" or "DEC" to select the desired data number.
- Press and hold "Start/Enter" for more than 3 seconds to load the data.
7.3. Various Information in the Program
During operation, you can press the "DEC" key to view various user settings or the "INC" key to monitor individual cell voltages (if a multi-cell battery is connected via balance port).
- End Voltage: Displays the final voltage reached when the program ended.
- Capacity Cut-Off: Shows if the function is ON and the set capacity limit.
- Safety Timer: Indicates if the timer is ON and its duration in minutes.
- Temp Cut-Off: Shows if the temperature cut-off is ON and the set temperature.
- Ext. Temp: Displays the external temperature if a probe is used.
- IN Power Voltage: Shows the current input voltage.
- Cell Voltages: Displays individual cell voltages (up to 6 batteries) when connected via balance port.
8. Troubleshooting: Warning and Error Messages
The iMAX B6 V2 incorporates various functions to verify processes and the state of the electronics. In case of an error, the screen will display a message and emit an audible sound. Refer to the table below for common messages and their meanings:
| Error Message | Meaning / Action |
|---|---|
| REVERSE POLARITY | Incorrect polarity connected. Check connections. |
| CONNECTION BREAK | Battery connection is interrupted. Check all cables. |
| SHORT ERR | Short-circuit of the output termination. Disconnect immediately and check for shorts. |
| INPUT VOL ERR | Input voltage protection activated. Check input power supply voltage. |
| VOL SELECT ERR | The voltage of the battery pack has been selected incorrectly! Verify battery type and cell count. |
| BREAK DOWN | The charger has malfunctioned. Seek professional advice. |
| BATTERY CHECK LOW VOLTAGE | The battery voltage is lower than the set value. Check the number of cells in the battery pack. |
| BATTERY CHECK HIGH VOLTAGE | The battery voltage is higher than the set value. Check the number of cells in the battery pack. |
| BATTERY VOLTAGE CELL LOW VOL | Voltage of one cell in the battery pack is too low. Check individual cell voltages. |
| BATTERY VOLTAGE CELL HIGH VOL | Voltage of one cell in the battery pack is too high. Check individual cell voltages. |
| BATTERY VOL ERR CELL CONNECT | Wrong connection of the connector detected. Check the connector and cable. |
| CONTROL FAILURE | The processor cannot control the feeding current. Repair is needed. |
9. User Tips
- For NiCd/NiMH batteries, utilizing the cyclic charge/discharge function regularly can help prevent the "memory effect" and maintain battery capacity.
- When charging Pb (lead-acid) batteries, always adhere to the manufacturer's recommended charge current, typically 1/10 of the battery's capacity, and enable the Capacity Cut-Off feature for safety.
- If you frequently charge the same type of battery, use the "Data Store" and "Load Data" functions to quickly recall your preferred settings, saving time and ensuring consistent charging parameters.
10. Recommended Accessories
To enhance the functionality and safety of your iMAX B6 V2 charger, the following accessories are recommended:
- 60W Switching Power Supply (if not included with your specific model)
- Temperature Sensor Cable (for enabling temperature cut-off feature)
- Various charging cables: XH Adaptor, HP/PQ Adaptor, TP/FP Adaptor, Dean charging cable, Tamiya charging cable, TRAXXAS charging cable, Glow charging cable, Bullet charging cable, EC3 charging cable, Crocodile clip charging cable, Futaba RX charging cable.
- PC-LINK USB adaptor (for PC-based analysis and characteristic display of the battery via USB port).
11. Warranty and Compliance
11.1. Warranty and Service
This product is guaranteed to be free of manufacturing and assembly defects for a period of one year from the time of purchase. The warranty covers material or operational defects present at the time of purchase. During this period, defective products will be repaired or replaced free of service charge. Proof of purchase (invoice or receipt) is required for warranty claims. This warranty is not valid for damage resulting from misuse, modification, or failure to follow the procedures outlined in this manual.
11.2. Conformity Declaration
The iMAX B6 V2 complies with all relevant and mandatory EC directives and FCC Part 15 Subpart B: 2008. The product has been tested to meet the following technical standards:
| Test Standard | Description | Result |
|---|---|---|
| EN 55014-1:2006 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 1: Emission | Conform |
| EN55014-2:1997+A1:2001 | Electromagnetic compatibility - Requirements for household appliances, electric tools and similar apparatus - Part 2: Immunity-Product family standard | Conform |
| EN61000-6-1(2007) | Electromagnetic compatibility (EMC) - Part 6-1: Generic standards - Immunity for residential, commercial and light-industrial environments | Conform |
| EN61000-6-3(2007) | Electromagnetic compatibility (EMC) - Part 6-3: Generic standards - Emission standard for residential, commercial and light-industrial environments | Conform |
Disposal Information: This symbol indicates that the product must not be disposed of with general household waste. Please take your charger to a local waste collection point or recycling center at the end of its useful life. This applies to all countries of the European Union and other regions with separate waste collection systems.
All specifications and figures are subject to change without notice. Printed in China © 2009.