Gaqqee XY-BT13L / XY-BT11L

Contents

Gaqqee XY-BT13L / XY-BT11L Coulomb Counter Battery Capacity Indicator Tester User Manual

Model: XY-BT13L / XY-BT11L

1. Introduction

The Gaqqee XY-BT13L / XY-BT11L is a versatile Coulomb Counter Battery Capacity Indicator Tester designed for DC 10-110V systems. It provides fully automatic charge and discharge management, bidirectional current detection, and real-time display of various battery parameters. This device is ideal for monitoring and managing the health and performance of rechargeable batteries, ensuring extended battery life and efficient operation.

2. Safety Information

  • Ensure all connections are secure and correct before applying power to prevent damage to the device or connected components.
  • Operate within the specified voltage range of DC 10-110V and maximum current of 30A (for BT13L) or 10A (for BT11L).
  • Avoid short circuits between terminals.
  • Do not expose the device to moisture or extreme temperatures outside the operating range of -10°C to 60°C.
  • Handle with care to prevent physical damage.

3. Product Overview

The device features a dedicated LCD display for clear parameter visualization, along with UP, DOWN, SET, and STOP buttons for navigation and configuration. It includes 30A charging and discharging relay switches for automated control and supports serial communication via Modbus protocol, allowing for integration with TTL-to-RS485 or WiFi modules for remote control.

Gaqqee Coulomb Counter Battery Capacity Indicator Tester front view
Front view of the Gaqqee Coulomb Counter Battery Capacity Indicator Tester.
Gaqqee Coulomb Counter Battery Capacity Indicator Tester back view with MCU details
Back view showing the 48-Pin MCU controller and high-precision sampling chip.

4. Specifications

ParameterValue
NameBattery Manage-Charge and Discharge
ModelXY-BT13L / XY-BT11L
Battery Voltage Range10-110V
Adapter Input Voltage Range10-110V
Maximum Current (BT13L)30A
Maximum Current (BT11L)10A
Voltage Accuracy±0.5% + 1 word
Current Accuracy±0.5% + 3 words
Operating Temperature-10°C to 60°C
Voltage Resolution0.01V
Current Resolution0.01A
Screen Size1.8 inches
Product Size (BT13L)80x78x22mm
Product Size (BT11L)73x70x22mm
Product Weight (BT13L)100g (126g with package)
Product Weight (BT11L)62g (89g with package)

5. Setup & Wiring

Proper wiring is essential for the safe and correct operation of the device. Refer to the diagram below for connection details.

Wiring diagram for Gaqqee Coulomb Counter showing connections for charger, battery, load, and communication interfaces.
Wiring and Button Functions Diagram.

Connection Points:

  • IN+ / IN-: Input terminals for the charger.
  • BT+ / BT-: Terminals for connecting the battery/rechargeable battery.
  • OUT+ / OUT-: Output terminals for connecting the load.
  • NTC OUT: Connector for an external NTC temperature probe.
  • Serial Communication Interface: Supports standard Modbus Protocol. Can be connected to a TTL-to-RS485 module for RS485 communication or a WiFi module for remote control and unmanned operation.

Setup Demonstration Video:

Play video
Watch video online
Video demonstrating the wiring and basic operation of the battery management module.

6. Operation

6.1. Basic Display Navigation

On any operation interface, briefly press the SET button to cycle through the display content on the lower screen. The product supports displaying: Current (A), Power (W), Capacity (Ah), Energy (Wh), Percentage (%), Runtime (h), and Temperature (°C/°F).

Product Operation UI showing various parameters like voltage, current, power, capacity, energy, state of charge, runtime, and temperature.
Product Operation User Interface (UI) showing various parameters.

6.2. Product Operation UI Parameters

  • Current (A): Charging current or discharging current.
  • Power (W): Charging power or discharging power.
  • Capacity (Ah): Real-time display of battery remaining capacity.
  • Energy (Wh): Real-time display of battery remaining energy.
  • %: Relatively accurate remaining capacity percentage.
  • Runtime (h): Starts counting when the device exits pause mode, resets during mode switching, and can serve as a pause condition.
  • Temperature (°C/°F): Displays external temperature if a probe is connected, otherwise internal circuit board temperature.

6.3. Charging and Discharging Modes

The device automatically transitions between charging and discharging modes based on predefined conditions:

Diagram illustrating the transition between Charge Mode and Discharge Mode based on battery conditions.
Charge and Discharge Mode Transition.

Entering Discharge Mode (Charging Completion Conditions):

  1. Battery voltage > overvoltage protection threshold.
  2. Battery capacity is full.
  3. Charging current < minimum current threshold (LAP).
  4. Charge time > time threshold (OHP).

Upon meeting any of these conditions, charging is completed, and the system enters discharge mode. (Note: LAP and OHP can be turned on or off automatically.)

Entering Charging Mode (Discharging Completion Conditions):

  1. Battery voltage < undervoltage protection threshold.
  2. Battery capacity < low power protection.
  3. Discharge current < minimum current threshold (LAP).
  4. Discharge time > time threshold (OHP).

Upon satisfying any of these conditions, discharge is completed, and the system transitions into charging mode. (Note: LBP, LAP, and OHP can be turned on or off automatically.)

6.4. UPS Mode Description

In UPS (Uninterruptible Power Supply) mode, both the charging and discharging relays remain simultaneously closed. The charger supplies power to both the battery (charging) and the load. When the battery is fully charged, the charging relay maintains connection. If AC power fails, the battery automatically powers the load until depleted. When AC power resumes, the system automatically restores charging while continuing to power the load. This mode requires the charger's output power to exceed the sum of charging power and load power.

UPS Mode Description showing current display and how to enable/disable.
UPS Mode Description.

Current Description in UPS Mode:

When the charger simultaneously charges the battery and powers the load, the displayed current indicates the battery charging current. If the charger disconnects (or malfunctions), the charging icon will flash rapidly to signal charger failure. During this time, the battery automatically powers the load, and the displayed current switches to battery discharge current.

How to Enable/Disable UPS Mode:

Long press the SET button to enter settings, then set the FUC parameter to "UPS" to enable UPS mode. Set to other values to disable UPS mode.

UPS Mode Button Function:

Short press the STOP button for emergency stop.

7. System Parameter Configuration

To configure system parameters, long-press the SET button to enter the settings interface. Use the UP/DOWN buttons to modify values. For toggle-type parameters (indicated by '----'), long-press STOP to enable/disable. Long-press SET again to confirm settings and exit configuration mode.

System Parameter Configuration for various protection settings like LVP, OVP, LAP, OCP.
System Parameter Configuration (Part 1).
System Parameter Configuration for various protection settings like OHP, OTP, ETP, dOP, FOP, LOP.
System Parameter Configuration (Part 2).
System Parameter Configuration for various settings like BEP, Add, C-F, CLU, CLA, ZERO, RET.
System Parameter Configuration (Part 3).

Parameter Descriptions:

  • CAP SET (Set Battery Full Capacity): Set the specific capacity if known. If unknown, the system will automatically record it after capacity calibration.
  • FUC SET (Charging Mode Operation): Select operating mode: Charging (CH), Discharging (dCH), or UPS (uninterruptible power supply).
  • LBP SET (Low Battery Alarm Threshold): When battery percentage falls below this, audible/visual alarms activate, and the system switches to charging mode.
  • LVP SET (Under-Voltage Protection): If battery voltage drops below this parameter, alarms activate, and the system switches to charging mode.
  • OVP SET (Over-Voltage Protection): If battery voltage exceeds this parameter, alarms activate, and the system switches to discharge mode.
  • LAP SET (Current Threshold): When enabled in charge/discharge modes, the system automatically switches modes if current falls below this value. (Inactive in UPS mode).
  • OCP SET (Over-Current Protection): If charging/discharging current reaches this parameter, the relay disconnects with alarms.
  • OHP SET (Runtime Protection): After setting a duration, the device accumulates operating time. Upon reaching the set time, it automatically switches charge/discharge modes.
  • OTP SET (Over-Temperature Protection): If PCB temperature near the relay reaches this value, the device shuts down for protection.
  • ETP SET (External Over-Temperature Protection): If an external temperature probe is connected and temperature exceeds this value, the device shuts down for protection.
  • dOP SET (Turn-On Delay Time): After setting and enabling, the system enters a delay countdown during mode switching.
  • FOP SET (Forced Turn-On Time): When enabled, the system enters forced conduction state during mode transitions and device startup to prevent false triggering.
  • LOP SET (Cycle Threshold): One complete charge and discharge process constitutes a cycle. The system counts completed cycles and triggers an LOP alarm when the count matches the parameter.
  • POd SET (Power-On Status Parameters): ON: Automatically operates in the FUC-set mode upon power-on. OFF: Remains inactive (emergency stop state) after power-on.
  • BEP SET (Buzzer Enable/Disable): ON: Turn on buzzer. OFF: Turn off buzzer.
  • Add SET (ModBus Address Setting): Sets the Modbus address (1-247).
  • C-F SET (Temperature Unit Switch): Selects between Celsius (°C) and Fahrenheit (°F).
  • CLU SET (Voltage Calibration): Calibrate voltage readings using a high-precision multimeter.
  • CLA SET (Current Calibration): Calibrate current readings using a high-precision ammeter.
  • ZERO SET (Current Zero-Point Calibration): Calibrate current zero-point.
  • RET SET (Factory Reset): Resets all parameters to factory defaults.

8. Capacity Correction

To ensure proper operation and accurate readings, it is necessary to correctly set the actual effective capacity of the battery. This is especially important when using the device for the first time or replacing a battery. There are two methods for capacity correction:

8.1. Capacity Correction Mode - Unknown Capacity

This method is used when the battery's capacity is unknown and requires active calibration by the device.

Diagram for capacity correction when battery capacity is unknown.
Capacity Correction Mode - Unknown Capacity.
  1. Step 1: To enter the Capacity Correction Mode, ensure that the charger, rechargeable battery, and load are properly connected.
  2. Step 2: Press the SET button briefly to switch the interface to the capacity parameter (Ah) interface.
  3. Step 3: Press and hold the UP button for more than 5 seconds to enter the Capacity Correction Mode.

To forcibly exit the Capacity Correction mode during the process, press and hold the UP button for more than 5 seconds.

8.2. Capacity Correction Mode - Known Capacity

This method is used when the battery's capacity is already known.

Diagram for capacity correction when battery capacity is known.
Capacity Correction Mode - Known Capacity.
  1. Step 1: Press and hold the SET button for 2 seconds on the main UI to enter the settings interface.
  2. Step 2: Press the UP/DOWN buttons shortly to adjust the parameter value for CAP SET. Short-press STOP button to shift position.
  3. Step 3: After completing the capacity parameter settings, long-press the SET button for 2 seconds again to exit the settings interface. The parameters will be saved automatically.

9. Protection and Alarms

The device evaluates transition conditions and notifies users when criteria are met. Alerts persist for 5 seconds before automatically clearing.

Table of Charge/Discharge Mode Transition Alerts and Alarm Function with codes and priority.
Charge/Discharge Mode Transition Alerts and Alarm Function.

Charge/Discharge Mode Transition Alerts:

  • OVP: Battery overvoltage condition met
  • LVP: Battery undervoltage condition met
  • LAP: Current threshold condition met
  • OHP: OHP Time threshold condition met
  • CAP: CAP Capacity threshold condition met

Alarm Function:

When an alarm is triggered, the screen and alarm code flash, and the buzzer sounds for 60 seconds. If multiple alarms occur simultaneously, only the highest priority alarm code is displayed.

Alarm Codes and Priority Ranking:

CodeDescription
1-OCPOvercurrent alarm
2-nbEBattery not connected alarm
3-nCHCharger not connected alarm
4-REVReverse current alarm: Current direction does not match the current mode
5-VOEVoltage anomaly alarm: Triggered when battery voltage exceeds charger voltage during charging after relay activation
6-OTPDevice overtemperature alarm
7-ETPExternal overtemperature alarm
8-LOPCycle threshold alarm
9-HFCRelay high-frequency operation alarm (to prevent relay damage)
10-OVPBattery overvoltage alarm
11-LVPBattery undervoltage alarm

10. Communication Protocol (Modbus RTU)

The device utilizes the MODBUS RTU protocol for serial communication via a TTL serial port. Information transmission is asynchronous, using 11-bit bytes.

10.1. Word Format

ParameterValue
Data Type (serial data)10-bit binary
Start BitOne
Data BitEight
Parity Check BitNone
Stop BitOne

10.2. Data Frame Structure

ParameterSize
Data Frame IntervalOf 3.5 bytes and above
Address Code1 Byte
FC (Function Code)1 Byte
Data FieldN Bytes
CRC Verification2 Bytes

The address code is the first byte (8 bits) of each communication message frame, ranging from 1 to 255. This byte indicates the address set by the user.

10.3. Function Codes

The function code is the second byte of each communication information frame transmission. The device supports function codes 0x03 (Read Register Data), 0x06 (Write Single Register), and 0x10 (Write Multiple Registers).

FCDefinitionOperation (Binary)
0x03Read register dataReads the data for one or more registers
0x06Write a single registerWrite a set of binary data to a single register
0x10Write multiple registersWrite multiple sets of binary data to multiple registers

10.4. Protocol Register Introduction

The data in a single register address is double-byte data. The factory default port rate is 115200, and the device address is 1.

NameDescriptionBytesDecimal PointUnitRead/WriteRegister Address (Decimal)Register Address (Hex)
MODECharge and discharge mode20-R/W00x0000
CH_RELAYCharging relay status20-R10x0001
DCH_RELAYDischarging relay status20-R20x0002
AH - LOWLower 16 bits of remaining capacity20mAhR30x0003
AH - HIGHUpper 16 bits of remaining capacity20mAhR40x0004
WH - LOWLower 16 bits of energy20mWhR50x0005
WH - HIGHUpper 16 bits of energy20mWhR60x0006
PERPercentage21%R70x0007
VCHARGECharger voltage22VR80x0008
VBATBattery voltage22VR90x0009
IBATBattery current22AR100x000A
W - LOWLower 16 bits of power20mWR110x000B
W - HIGHUpper 16 bits of power20mWR120x000C
CH_RuntimeCharging running time20MinsR130x000D
DCH_RuntimeDischarging running time20MinsR140x000E
LOOPCOUNTNumber of cycles completed20-R150x000F
IN_TEMPDevice temperature21°CR160x0010
EX_TEMPBattery temperature21°CR170x0011
ALARMAlarm status20-R/W180x0012
STOPMode pause20-R/W190x0013
LEARNLearning mode20-R/W200x0014
CAPEffective capacity21AhR/W210x0015
LBPLow battery protection21%R/W220x0016
LVPDischarge undervoltage protection21VR/W230x0017
OVPCharge overvoltage protection21VR/W240x0018
LAPThreshold current22AR/W250x0019
OCPOvercurrent protection22AR/W260x001A
OHPLimiting time20MinsR/W270x001B
OTPDevice overtemperature protection20°C/FR/W280x001C
ETPBattery overtemperature protection20°C/FR/W290x001D
DOPDelayed action time20SR/W300x001E
FOPForced conduction time20SR/W310x001F
LOPCycle number threshold20-R/W320x0020
FUCMode selection20-R/W330x0021
POdPower - on action selection20-R/W340x0022
BEPBuzzer switch20-R/W350x0023
ADDMODBUS address20-R/W360x0024
C_FTemperature unit switch20-R/W370x0025
BAUDBaud rate20-R/W380x0026
LOCKKey lock20-R/W390x0027
LIGHTChange backlight brightness20-R/W400x0028
PRODUCT_MODELProduct model20-R410x0029
VERSIONProduct code version number20-R420x002A

11. User Tips

  • Capacity Calculation: The device calculates charge percentage based on the amount of energy (Ah) that has passed through it, not solely on voltage. If you connect the module to an already charged battery, it might initially display it as discharged until it completes a learning cycle or capacity correction is performed.
  • Initial Setup: While the module is generally easy to use once configured, the initial setup, especially parameter configuration and calibration, can be complex. Refer to this manual carefully or seek translation assistance if needed.
  • Modbus Communication: The device supports standard Modbus protocol, allowing for advanced integration and remote control via TTL-to-RS485 or WiFi modules.

12. Troubleshooting

  • No Display/Incorrect Readings: Check all wiring connections (IN+, IN-, BT+, BT-, OUT+, OUT-) for proper polarity and secure contact. Ensure the input voltage is within the 10-110V DC range.
  • Device Not Charging/Discharging: Verify that the charging and discharging relays are functioning correctly. Check the FUC SET parameter to ensure the correct operating mode (CH, dCH, UPS) is selected. Review OVP, LVP, LAP, OCP, OHP, OTP, ETP, dOP, FOP, and LOP settings, as these can prevent operation.
  • Inaccurate Capacity/Percentage: Perform a capacity correction (refer to Section 8) to ensure the device accurately learns or is set to the battery's effective capacity.
  • Alarm Triggered: Refer to the 'Alarm Codes and Priority Ranking' table in Section 9 to identify the specific alarm and its cause. Address the underlying issue (e.g., overcurrent, undervoltage, overtemperature).
  • Communication Issues (Modbus): Ensure correct wiring for the serial communication interface. Verify Modbus address (ADD SET) and baud rate (BAUD SET) parameters match your communication setup.
  • Device Unresponsive: Try a factory reset (RET SET) as a last resort, but note that this will clear all custom settings.

13. Maintenance

  • Keep the device clean and free from dust and debris.
  • Avoid exposing the device to water or high humidity.
  • Store in a dry environment within the specified operating temperature range.
  • Regularly check wiring connections for looseness or corrosion.

14. Warranty & Support

For any technical assistance, troubleshooting beyond this manual, or warranty inquiries, please contact the seller or manufacturer directly. Ensure you have your purchase details and model number (XY-BT13L / XY-BT11L) available for faster service.

A detailed user manual in PDF format is available for download: View User Manual (PDF)