1. Introduction
The Gaqqee XY-BT13L / XY-BT11L is a versatile Coulomb Counter Battery Capacity Indicator Tester designed for DC 10-110V systems. It provides fully automatic charge and discharge management, bidirectional current detection, and real-time display of various battery parameters. This device is ideal for monitoring and managing the health and performance of rechargeable batteries, ensuring extended battery life and efficient operation.
2. Safety Information
- Ensure all connections are secure and correct before applying power to prevent damage to the device or connected components.
- Operate within the specified voltage range of DC 10-110V and maximum current of 30A (for BT13L) or 10A (for BT11L).
- Avoid short circuits between terminals.
- Do not expose the device to moisture or extreme temperatures outside the operating range of -10°C to 60°C.
- Handle with care to prevent physical damage.
3. Product Overview
The device features a dedicated LCD display for clear parameter visualization, along with UP, DOWN, SET, and STOP buttons for navigation and configuration. It includes 30A charging and discharging relay switches for automated control and supports serial communication via Modbus protocol, allowing for integration with TTL-to-RS485 or WiFi modules for remote control.


4. Specifications
| Parameter | Value |
|---|---|
| Name | Battery Manage-Charge and Discharge |
| Model | XY-BT13L / XY-BT11L |
| Battery Voltage Range | 10-110V |
| Adapter Input Voltage Range | 10-110V |
| Maximum Current (BT13L) | 30A |
| Maximum Current (BT11L) | 10A |
| Voltage Accuracy | ±0.5% + 1 word |
| Current Accuracy | ±0.5% + 3 words |
| Operating Temperature | -10°C to 60°C |
| Voltage Resolution | 0.01V |
| Current Resolution | 0.01A |
| Screen Size | 1.8 inches |
| Product Size (BT13L) | 80x78x22mm |
| Product Size (BT11L) | 73x70x22mm |
| Product Weight (BT13L) | 100g (126g with package) |
| Product Weight (BT11L) | 62g (89g with package) |
5. Setup & Wiring
Proper wiring is essential for the safe and correct operation of the device. Refer to the diagram below for connection details.

Connection Points:
- IN+ / IN-: Input terminals for the charger.
- BT+ / BT-: Terminals for connecting the battery/rechargeable battery.
- OUT+ / OUT-: Output terminals for connecting the load.
- NTC OUT: Connector for an external NTC temperature probe.
- Serial Communication Interface: Supports standard Modbus Protocol. Can be connected to a TTL-to-RS485 module for RS485 communication or a WiFi module for remote control and unmanned operation.
Setup Demonstration Video:
6. Operation
6.1. Basic Display Navigation
On any operation interface, briefly press the SET button to cycle through the display content on the lower screen. The product supports displaying: Current (A), Power (W), Capacity (Ah), Energy (Wh), Percentage (%), Runtime (h), and Temperature (°C/°F).

6.2. Product Operation UI Parameters
- Current (A): Charging current or discharging current.
- Power (W): Charging power or discharging power.
- Capacity (Ah): Real-time display of battery remaining capacity.
- Energy (Wh): Real-time display of battery remaining energy.
- %: Relatively accurate remaining capacity percentage.
- Runtime (h): Starts counting when the device exits pause mode, resets during mode switching, and can serve as a pause condition.
- Temperature (°C/°F): Displays external temperature if a probe is connected, otherwise internal circuit board temperature.
6.3. Charging and Discharging Modes
The device automatically transitions between charging and discharging modes based on predefined conditions:

Entering Discharge Mode (Charging Completion Conditions):
- Battery voltage > overvoltage protection threshold.
- Battery capacity is full.
- Charging current < minimum current threshold (LAP).
- Charge time > time threshold (OHP).
Upon meeting any of these conditions, charging is completed, and the system enters discharge mode. (Note: LAP and OHP can be turned on or off automatically.)
Entering Charging Mode (Discharging Completion Conditions):
- Battery voltage < undervoltage protection threshold.
- Battery capacity < low power protection.
- Discharge current < minimum current threshold (LAP).
- Discharge time > time threshold (OHP).
Upon satisfying any of these conditions, discharge is completed, and the system transitions into charging mode. (Note: LBP, LAP, and OHP can be turned on or off automatically.)
6.4. UPS Mode Description
In UPS (Uninterruptible Power Supply) mode, both the charging and discharging relays remain simultaneously closed. The charger supplies power to both the battery (charging) and the load. When the battery is fully charged, the charging relay maintains connection. If AC power fails, the battery automatically powers the load until depleted. When AC power resumes, the system automatically restores charging while continuing to power the load. This mode requires the charger's output power to exceed the sum of charging power and load power.

Current Description in UPS Mode:
When the charger simultaneously charges the battery and powers the load, the displayed current indicates the battery charging current. If the charger disconnects (or malfunctions), the charging icon will flash rapidly to signal charger failure. During this time, the battery automatically powers the load, and the displayed current switches to battery discharge current.
How to Enable/Disable UPS Mode:
Long press the SET button to enter settings, then set the FUC parameter to "UPS" to enable UPS mode. Set to other values to disable UPS mode.
UPS Mode Button Function:
Short press the STOP button for emergency stop.
7. System Parameter Configuration
To configure system parameters, long-press the SET button to enter the settings interface. Use the UP/DOWN buttons to modify values. For toggle-type parameters (indicated by '----'), long-press STOP to enable/disable. Long-press SET again to confirm settings and exit configuration mode.



Parameter Descriptions:
- CAP SET (Set Battery Full Capacity): Set the specific capacity if known. If unknown, the system will automatically record it after capacity calibration.
- FUC SET (Charging Mode Operation): Select operating mode: Charging (CH), Discharging (dCH), or UPS (uninterruptible power supply).
- LBP SET (Low Battery Alarm Threshold): When battery percentage falls below this, audible/visual alarms activate, and the system switches to charging mode.
- LVP SET (Under-Voltage Protection): If battery voltage drops below this parameter, alarms activate, and the system switches to charging mode.
- OVP SET (Over-Voltage Protection): If battery voltage exceeds this parameter, alarms activate, and the system switches to discharge mode.
- LAP SET (Current Threshold): When enabled in charge/discharge modes, the system automatically switches modes if current falls below this value. (Inactive in UPS mode).
- OCP SET (Over-Current Protection): If charging/discharging current reaches this parameter, the relay disconnects with alarms.
- OHP SET (Runtime Protection): After setting a duration, the device accumulates operating time. Upon reaching the set time, it automatically switches charge/discharge modes.
- OTP SET (Over-Temperature Protection): If PCB temperature near the relay reaches this value, the device shuts down for protection.
- ETP SET (External Over-Temperature Protection): If an external temperature probe is connected and temperature exceeds this value, the device shuts down for protection.
- dOP SET (Turn-On Delay Time): After setting and enabling, the system enters a delay countdown during mode switching.
- FOP SET (Forced Turn-On Time): When enabled, the system enters forced conduction state during mode transitions and device startup to prevent false triggering.
- LOP SET (Cycle Threshold): One complete charge and discharge process constitutes a cycle. The system counts completed cycles and triggers an LOP alarm when the count matches the parameter.
- POd SET (Power-On Status Parameters): ON: Automatically operates in the FUC-set mode upon power-on. OFF: Remains inactive (emergency stop state) after power-on.
- BEP SET (Buzzer Enable/Disable): ON: Turn on buzzer. OFF: Turn off buzzer.
- Add SET (ModBus Address Setting): Sets the Modbus address (1-247).
- C-F SET (Temperature Unit Switch): Selects between Celsius (°C) and Fahrenheit (°F).
- CLU SET (Voltage Calibration): Calibrate voltage readings using a high-precision multimeter.
- CLA SET (Current Calibration): Calibrate current readings using a high-precision ammeter.
- ZERO SET (Current Zero-Point Calibration): Calibrate current zero-point.
- RET SET (Factory Reset): Resets all parameters to factory defaults.
8. Capacity Correction
To ensure proper operation and accurate readings, it is necessary to correctly set the actual effective capacity of the battery. This is especially important when using the device for the first time or replacing a battery. There are two methods for capacity correction:
8.1. Capacity Correction Mode - Unknown Capacity
This method is used when the battery's capacity is unknown and requires active calibration by the device.

- Step 1: To enter the Capacity Correction Mode, ensure that the charger, rechargeable battery, and load are properly connected.
- Step 2: Press the SET button briefly to switch the interface to the capacity parameter (Ah) interface.
- Step 3: Press and hold the UP button for more than 5 seconds to enter the Capacity Correction Mode.
To forcibly exit the Capacity Correction mode during the process, press and hold the UP button for more than 5 seconds.
8.2. Capacity Correction Mode - Known Capacity
This method is used when the battery's capacity is already known.

- Step 1: Press and hold the SET button for 2 seconds on the main UI to enter the settings interface.
- Step 2: Press the UP/DOWN buttons shortly to adjust the parameter value for CAP SET. Short-press STOP button to shift position.
- Step 3: After completing the capacity parameter settings, long-press the SET button for 2 seconds again to exit the settings interface. The parameters will be saved automatically.
9. Protection and Alarms
The device evaluates transition conditions and notifies users when criteria are met. Alerts persist for 5 seconds before automatically clearing.

Charge/Discharge Mode Transition Alerts:
- OVP: Battery overvoltage condition met
- LVP: Battery undervoltage condition met
- LAP: Current threshold condition met
- OHP: OHP Time threshold condition met
- CAP: CAP Capacity threshold condition met
Alarm Function:
When an alarm is triggered, the screen and alarm code flash, and the buzzer sounds for 60 seconds. If multiple alarms occur simultaneously, only the highest priority alarm code is displayed.
Alarm Codes and Priority Ranking:
| Code | Description |
|---|---|
| 1-OCP | Overcurrent alarm |
| 2-nbE | Battery not connected alarm |
| 3-nCH | Charger not connected alarm |
| 4-REV | Reverse current alarm: Current direction does not match the current mode |
| 5-VOE | Voltage anomaly alarm: Triggered when battery voltage exceeds charger voltage during charging after relay activation |
| 6-OTP | Device overtemperature alarm |
| 7-ETP | External overtemperature alarm |
| 8-LOP | Cycle threshold alarm |
| 9-HFC | Relay high-frequency operation alarm (to prevent relay damage) |
| 10-OVP | Battery overvoltage alarm |
| 11-LVP | Battery undervoltage alarm |
10. Communication Protocol (Modbus RTU)
The device utilizes the MODBUS RTU protocol for serial communication via a TTL serial port. Information transmission is asynchronous, using 11-bit bytes.
10.1. Word Format
| Parameter | Value |
|---|---|
| Data Type (serial data) | 10-bit binary |
| Start Bit | One |
| Data Bit | Eight |
| Parity Check Bit | None |
| Stop Bit | One |
10.2. Data Frame Structure
| Parameter | Size |
|---|---|
| Data Frame Interval | Of 3.5 bytes and above |
| Address Code | 1 Byte |
| FC (Function Code) | 1 Byte |
| Data Field | N Bytes |
| CRC Verification | 2 Bytes |
The address code is the first byte (8 bits) of each communication message frame, ranging from 1 to 255. This byte indicates the address set by the user.
10.3. Function Codes
The function code is the second byte of each communication information frame transmission. The device supports function codes 0x03 (Read Register Data), 0x06 (Write Single Register), and 0x10 (Write Multiple Registers).
| FC | Definition | Operation (Binary) |
|---|---|---|
| 0x03 | Read register data | Reads the data for one or more registers |
| 0x06 | Write a single register | Write a set of binary data to a single register |
| 0x10 | Write multiple registers | Write multiple sets of binary data to multiple registers |
10.4. Protocol Register Introduction
The data in a single register address is double-byte data. The factory default port rate is 115200, and the device address is 1.
| Name | Description | Bytes | Decimal Point | Unit | Read/Write | Register Address (Decimal) | Register Address (Hex) |
|---|---|---|---|---|---|---|---|
| MODE | Charge and discharge mode | 2 | 0 | - | R/W | 0 | 0x0000 |
| CH_RELAY | Charging relay status | 2 | 0 | - | R | 1 | 0x0001 |
| DCH_RELAY | Discharging relay status | 2 | 0 | - | R | 2 | 0x0002 |
| AH - LOW | Lower 16 bits of remaining capacity | 2 | 0 | mAh | R | 3 | 0x0003 |
| AH - HIGH | Upper 16 bits of remaining capacity | 2 | 0 | mAh | R | 4 | 0x0004 |
| WH - LOW | Lower 16 bits of energy | 2 | 0 | mWh | R | 5 | 0x0005 |
| WH - HIGH | Upper 16 bits of energy | 2 | 0 | mWh | R | 6 | 0x0006 |
| PER | Percentage | 2 | 1 | % | R | 7 | 0x0007 |
| VCHARGE | Charger voltage | 2 | 2 | V | R | 8 | 0x0008 |
| VBAT | Battery voltage | 2 | 2 | V | R | 9 | 0x0009 |
| IBAT | Battery current | 2 | 2 | A | R | 10 | 0x000A |
| W - LOW | Lower 16 bits of power | 2 | 0 | mW | R | 11 | 0x000B |
| W - HIGH | Upper 16 bits of power | 2 | 0 | mW | R | 12 | 0x000C |
| CH_Runtime | Charging running time | 2 | 0 | Mins | R | 13 | 0x000D |
| DCH_Runtime | Discharging running time | 2 | 0 | Mins | R | 14 | 0x000E |
| LOOPCOUNT | Number of cycles completed | 2 | 0 | - | R | 15 | 0x000F |
| IN_TEMP | Device temperature | 2 | 1 | °C | R | 16 | 0x0010 |
| EX_TEMP | Battery temperature | 2 | 1 | °C | R | 17 | 0x0011 |
| ALARM | Alarm status | 2 | 0 | - | R/W | 18 | 0x0012 |
| STOP | Mode pause | 2 | 0 | - | R/W | 19 | 0x0013 |
| LEARN | Learning mode | 2 | 0 | - | R/W | 20 | 0x0014 |
| CAP | Effective capacity | 2 | 1 | Ah | R/W | 21 | 0x0015 |
| LBP | Low battery protection | 2 | 1 | % | R/W | 22 | 0x0016 |
| LVP | Discharge undervoltage protection | 2 | 1 | V | R/W | 23 | 0x0017 |
| OVP | Charge overvoltage protection | 2 | 1 | V | R/W | 24 | 0x0018 |
| LAP | Threshold current | 2 | 2 | A | R/W | 25 | 0x0019 |
| OCP | Overcurrent protection | 2 | 2 | A | R/W | 26 | 0x001A |
| OHP | Limiting time | 2 | 0 | Mins | R/W | 27 | 0x001B |
| OTP | Device overtemperature protection | 2 | 0 | °C/F | R/W | 28 | 0x001C |
| ETP | Battery overtemperature protection | 2 | 0 | °C/F | R/W | 29 | 0x001D |
| DOP | Delayed action time | 2 | 0 | S | R/W | 30 | 0x001E |
| FOP | Forced conduction time | 2 | 0 | S | R/W | 31 | 0x001F |
| LOP | Cycle number threshold | 2 | 0 | - | R/W | 32 | 0x0020 |
| FUC | Mode selection | 2 | 0 | - | R/W | 33 | 0x0021 |
| POd | Power - on action selection | 2 | 0 | - | R/W | 34 | 0x0022 |
| BEP | Buzzer switch | 2 | 0 | - | R/W | 35 | 0x0023 |
| ADD | MODBUS address | 2 | 0 | - | R/W | 36 | 0x0024 |
| C_F | Temperature unit switch | 2 | 0 | - | R/W | 37 | 0x0025 |
| BAUD | Baud rate | 2 | 0 | - | R/W | 38 | 0x0026 |
| LOCK | Key lock | 2 | 0 | - | R/W | 39 | 0x0027 |
| LIGHT | Change backlight brightness | 2 | 0 | - | R/W | 40 | 0x0028 |
| PRODUCT_MODEL | Product model | 2 | 0 | - | R | 41 | 0x0029 |
| VERSION | Product code version number | 2 | 0 | - | R | 42 | 0x002A |
11. User Tips
- Capacity Calculation: The device calculates charge percentage based on the amount of energy (Ah) that has passed through it, not solely on voltage. If you connect the module to an already charged battery, it might initially display it as discharged until it completes a learning cycle or capacity correction is performed.
- Initial Setup: While the module is generally easy to use once configured, the initial setup, especially parameter configuration and calibration, can be complex. Refer to this manual carefully or seek translation assistance if needed.
- Modbus Communication: The device supports standard Modbus protocol, allowing for advanced integration and remote control via TTL-to-RS485 or WiFi modules.
12. Troubleshooting
- No Display/Incorrect Readings: Check all wiring connections (IN+, IN-, BT+, BT-, OUT+, OUT-) for proper polarity and secure contact. Ensure the input voltage is within the 10-110V DC range.
- Device Not Charging/Discharging: Verify that the charging and discharging relays are functioning correctly. Check the FUC SET parameter to ensure the correct operating mode (CH, dCH, UPS) is selected. Review OVP, LVP, LAP, OCP, OHP, OTP, ETP, dOP, FOP, and LOP settings, as these can prevent operation.
- Inaccurate Capacity/Percentage: Perform a capacity correction (refer to Section 8) to ensure the device accurately learns or is set to the battery's effective capacity.
- Alarm Triggered: Refer to the 'Alarm Codes and Priority Ranking' table in Section 9 to identify the specific alarm and its cause. Address the underlying issue (e.g., overcurrent, undervoltage, overtemperature).
- Communication Issues (Modbus): Ensure correct wiring for the serial communication interface. Verify Modbus address (ADD SET) and baud rate (BAUD SET) parameters match your communication setup.
- Device Unresponsive: Try a factory reset (RET SET) as a last resort, but note that this will clear all custom settings.
13. Maintenance
- Keep the device clean and free from dust and debris.
- Avoid exposing the device to water or high humidity.
- Store in a dry environment within the specified operating temperature range.
- Regularly check wiring connections for looseness or corrosion.