1. Introduction
This Aideepen Multifunction Meter is a versatile device designed for comprehensive real-time monitoring of various electrical parameters. It can simultaneously measure and display voltage, current, power, impedance, capacity, energy, temperature, time, and power percentage. Equipped with a 0.96-inch high-resolution color screen, it provides clear and accurate readings in diverse lighting conditions. This manual provides detailed instructions for setup, operation, and maintenance to ensure optimal performance and longevity of your device.
Video: Overview of the Aideepen Multifunction Meter and its features.
2. Package Contents
Please check the package carefully to ensure all items are present:
- 1 x Meter Head
- 2 x Connection Wires (XH-2.54-3P and VH-3.96-2P)
- 1 x NTC Temperature Sensor (Column waterproof probe NTC 10K 3950 1%, approx. 1m total length)

Image: The multifunction meter, NTC temperature sensor, and connection wires included in the package.

Image: Close-up of the column waterproof NTC 10K 3950 1% sensor (approx. 1m) and the XH-2.54-3P (red, black, yellow, 155mm) and VH-3.96-2P (coarse red, black, 165mm) wires.
3. Specifications
| Parameter | Value |
|---|---|
| Working Voltage | DC4~30V (Do not over-voltage power supply) |
| Voltage Measurement Range | DC0~100V (Error ±1.00V, 0.1V jumping) |
| Current Measurement Range | Unidirectional, 0.00A ~ 10.00A (Error ± 0.1A, 0.03A jumps) |
| Power Measurement Range | 00.00~1000W |
| Impedance Display Range | 0~99999Ω (non-internal resistance) |
| Capacity Measurement Range | 0~999999kAh |
| Energy Measurement Range | 0~999999kWh |
| Temperature Sensor | Column waterproof probe NTC 10K 3950 1% sensor (Total length approx. 1 meter) |
| Temperature Metering Range | -40~120°C (external temperature measured by NTC sensor) |
| Time Measurement Range | 0~999:59:59 (hours:minutes:seconds) |
| Standby Energy Consumption | 10mA (measured by DC12V) |
| Meter Size | 47.59×28.67×25.33mm |
| Mounting Hole Size | 45×26mm |
4. Safety Information
- Ensure the working voltage is within the specified DC4~30V range to prevent damage.
- Always connect the meter to the circuit with power off to avoid electric shock or damage to the device.
- Verify correct polarity when connecting wires.
- Do not expose the device to extreme temperatures, moisture, or corrosive environments.
- Keep out of reach of children.
5. Setup
5.1 Mounting
The meter requires a mounting hole of 45×26mm. Ensure a secure fit in your desired panel or enclosure.
5.2 Wiring Diagrams
There are two primary wiring methods: Common Power Wiring and Separate Power Wiring. Choose the method appropriate for your application.
5.2.1 Common Power Wiring
In this configuration, the meter's power supply is derived from the same source as the load being measured. This is suitable when the load's voltage is within the meter's operating voltage range (DC4-30V).

Image: Diagram illustrating common power wiring. The meter's power input (DC4-30V) and the load's power share the same source.
5.2.2 Separate Power Wiring
Use separate power wiring when the load's voltage (DC0-100V) is outside the meter's operating voltage range (DC4-30V) or if you prefer to isolate the meter's power. The meter will be powered by a separate DC4-30V source.

Image: Diagram illustrating separate power wiring. The meter is powered by a DC4-30V source, while the load is connected to a DC0-100V source.
5.3 NTC Temperature Sensor Connection
Connect the NTC temperature sensor to the designated port on the meter. The sensor is a column waterproof probe NTC 10K 3950 1% with a total length of approximately 1 meter. Ensure it is placed in the environment where temperature measurement is desired.
6. Operating Instructions
6.1 Display Overview
The 0.96-inch color screen displays multiple parameters simultaneously. Refer to the diagram below for an explanation of each displayed value:

Image: The meter's display showing various parameters with numbered labels.
- Real-time voltage
- Real-time current
- Real-time power
- Accumulated running time
- Celsius/Fahrenheit temperature display
- Load impedance
- Accumulated energy
- Cumulative capacity
- Extinguish the screen and count down
- Percentage power indicator based on voltage ratio
6.2 Menu Navigation
The meter features a menu system for advanced settings and adjustments. Use the buttons on the device to navigate and select options.

Image: Screenshots of the meter's menu interface, showing options for data clear, forced to zero, voltage/current fine-tuning, battery voltage settings, standby time, reset, and exit.
- 1. DATA CLEAR: Clears all accumulated data (history record).
- 2. FORCED TO ZERO: Forces the current reading to zero when no load is connected, preventing error accumulation.
- 3. V-ADJ: [Voltage Value]: Allows fine-tuning of the displayed voltage value. This does not affect the actual voltage.
- 4. A-ADJ: [Current Value]: Allows fine-tuning of the displayed current value. This does not affect the actual current.
- 5. V-LOW: [Voltage Value]: Sets the low voltage threshold for battery percentage calculation.
- 6. V-FULL: [Voltage Value]: Sets the full voltage threshold for battery percentage calculation.
- 7. STANDBY: [Time in seconds]: Sets the standby time before the screen turns off.
- 8. RESET: Resets all settings to factory defaults.
- 9. EXIT: Exits the menu.
6.3 Display Settings
The meter supports a screen-off function with a countdown. You can also set it to remain always on.

Image: Examples of the display showing a countdown to screen off (e.g., "Off 00:10") and the "No Screen Off" state ("Off --:--").
- Countdown to screen out: The display will show "Off" followed by a countdown (e.g., "00:10") before the screen turns off.
- No Screen Off: If configured, the display will show "Off --:--" indicating the screen will remain on indefinitely.
7. Maintenance
- Cleaning: Use a soft, dry cloth to clean the meter's display and casing. Do not use abrasive cleaners or solvents.
- Storage: Store the device in a cool, dry place away from direct sunlight and extreme temperatures when not in use.
- Inspection: Periodically check the wiring for any signs of wear or damage.
8. Troubleshooting
- No Display: Ensure the meter is correctly wired and receiving power within the DC4-30V range. Check all connections for looseness.
- Incorrect Readings:
- Verify that the wiring is correct for your application (Common or Separate Power).
- Use the "V-ADJ" and "A-ADJ" menu options to fine-tune the voltage and current readings if minor discrepancies are observed.
- Perform a "FORCED TO ZERO" operation if you suspect accumulated errors in no-load conditions.
- Temperature Reading Issues: Ensure the NTC sensor is properly connected and placed in the desired measurement area.
- Percentage Power Inaccurate: Manually set the "V-LOW" and "V-FULL" voltage values in the menu to accurately reflect your battery's characteristics.
- Device Unresponsive: Try performing a "RESET" from the menu to restore factory settings. If the issue persists, disconnect power, wait a few minutes, and reconnect.
9. User Tips
- Always double-check your wiring before applying power to prevent damage to the meter or your circuit.
- For precise battery monitoring, take the time to calibrate the "V-LOW" and "V-FULL" settings to match your specific battery's characteristics.
- Utilize the "DATA CLEAR" function regularly if you need to track cumulative values for specific test periods.
- The fine-tuning functions for voltage and current are useful for matching readings with a known reference meter for maximum accuracy.
10. Warranty and Support
For any technical assistance or warranty inquiries, please refer to the official product page or contact the seller directly. A user manual in PDF format may also be available for download from the product's online listing for additional details.