Hantek Hantek 2C42/2D72 Series

Contents

Hantek Digital Oscilloscope 2C42/2D72 Series User Manual

Models: Hantek 2C42, Hantek 2D42, Hantek 2C72, Hantek 2D72

1. Introduction

The Hantek 2C42/2D72 series offers a versatile 3-in-1 handheld measurement tool, combining the functionalities of a digital oscilloscope, a digital multimeter (DMM), and an arbitrary waveform generator (AWG). This manual provides essential information for the safe and effective operation of your device.

Video 1: Hantek 3-in-1 (2D72) Product Overview and Demonstration. This video highlights the oscilloscope, multimeter, and signal generator functions.

The series includes different models with varying bandwidths and features:

  • Hantek 2C42: 40MHz Bandwidth, 2 Channels + Digital Multimeter (DMM)
  • Hantek 2D42: 40MHz Bandwidth, 2 Channels + DMM + Arbitrary Waveform Generator (AWG)
  • Hantek 2C72: 70MHz Bandwidth, 2 Channels + Digital Multimeter (DMM)
  • Hantek 2D72: 70MHz Bandwidth, 2 Channels + DMM + Arbitrary Waveform Generator (AWG)

2. Safety Precautions

To ensure safe operation and prevent damage to the device or personal injury, please observe the following precautions:

  • It is strictly prohibited to conduct measurements beyond the rated voltage and insulation level of the device. This prevents electric shock and equipment explosion.
  • Measuring high-voltage circuits requires professional operation and proper insulation protection. Always use appropriate safety gear.
  • The probe should always be matched with the appropriate gear for the measurement task.
  • Do not plug or unplug the probe while the device is powered on. Avoid roughly pulling on probes or cables.
  • Protect the device against moisture, dust, and falls.
  • Keep the device away from strong electromagnetic interference sources.

3. Setup

Before operating the device, ensure proper setup:

  1. Unpacking and Inspection: Carefully unpack the device and all accessories. Inspect for any signs of damage.
  2. Power Supply: Connect the power adapter to the device and a suitable power outlet. The device includes a battery and can operate portably.
  3. Probe and Wiring: Connect the appropriate probes and test leads for your intended measurement. Ensure all connections are secure and correct.
  4. Initial Power On: After confirming all connections are correct, turn on the device. Allow a brief period for preheating and system initialization.
Hantek Handheld Oscilloscope with included accessories

Figure 1: Hantek Handheld Oscilloscope and its accessories, including probes, test leads, and power adapter.

4. Operating Instructions

The Hantek 2C42/2D72 series integrates an oscilloscope, multimeter, and (for 'D' models) a signal generator. Use the function buttons to switch between modes.

4.1 Oscilloscope Mode

To use the oscilloscope function:

  1. Press the Scope button to enter oscilloscope mode.
  2. Connect the signal under test to the CH1 or CH2 input ports at the top of the device.
  3. Adjust the voltage (vertical scale), time base (horizontal scale), and trigger settings using the navigation buttons and dedicated Trig, Channel, Time buttons.
  4. The Auto button can automatically adjust settings for a stable waveform display.
  5. Read the waveform displayed on the screen. Ensure that the input signal does not exceed the device's specified range to prevent overload damage.
Hantek Handheld Oscilloscope displaying a waveform

Figure 2: The Hantek oscilloscope displaying a complex waveform, demonstrating its measurement capabilities.

4.2 Multimeter Mode (DMM)

To use the digital multimeter function:

  1. Press the DMM button to switch to multimeter mode.
  2. Connect the test leads to the appropriate input terminals (A, mA, COM, V/Ω/C/+) at the bottom of the device based on the measurement type (voltage, current, resistance, capacitance, diode, continuity).
  3. Select the desired measurement function using the menu or dedicated buttons.
  4. The screen will display the measured value.
Close-up of Hantek device showing multimeter function with voltage reading

Figure 3: A close-up view of the Hantek device's screen in multimeter mode, showing a DC voltage measurement.

4.3 Arbitrary Waveform Generator (AWG) Mode (2D42/2D72 models only)

For models equipped with an AWG:

  1. Press the AWG button to enter the waveform generator mode.
  2. Connect the output of the AWG (Gen Out port at the top) to the circuit or device requiring a signal.
  3. Use the menu and navigation buttons to select the waveform type (Sine, Square, Triangular, Trapezoid), frequency, and amplitude.
  4. Adjust parameters as needed for your application.
Top view of Hantek device showing CH1, CH2, and Gen Out ports

Figure 4: Top view of the Hantek device, illustrating the CH1 and CH2 input channels for the oscilloscope, and the 'Gen Out' port for the arbitrary waveform generator.

5. Maintenance

Proper maintenance ensures the longevity and accuracy of your Hantek device:

  • Cleaning: Use a soft, dry cloth to clean the device. Do not use abrasive cleaners or solvents.
  • Storage: After use, turn off the device and tidy up the probes and cables. Store the device in a clean, dry environment, protected from moisture, dust, and direct sunlight.
  • Calibration: Regular calibration is recommended to maintain measurement accuracy. Non-professionals are advised not to disassemble the machine for calibration or repair.
  • Battery: The device includes a non-demountable battery. Refer to the specifications for battery life and charging instructions.
Back of Hantek device showing battery compartment and warning label

Figure 5: The back panel of the Hantek device, showing the battery compartment and important warning labels.

6. Troubleshooting

If you encounter issues with your Hantek device, consider the following general troubleshooting steps:

  • No Power: Ensure the power adapter is correctly connected and the outlet is functional. Check the device's battery charge level.
  • No Signal/Incorrect Reading: Verify that probes and test leads are securely connected to the correct ports and to the circuit under test. Check probe settings (e.g., 1X/10X attenuation). Ensure the device is in the correct measurement mode (Oscilloscope, DMM, AWG).
  • Unstable Waveform: Adjust the trigger level and mode. Use the 'Auto' button in oscilloscope mode to attempt automatic setup. Check the time base and vertical scale settings.
  • Device Malfunction: If the device behaves unexpectedly, try restarting it. If the problem persists, consult the detailed user manual (PDF) or contact customer support.

7. Specifications

FeatureSpecification
Brand NameHantek
Model Numbershantek2c42, hantek2d42, hantek2c72, hantek2d72
DIY SuppliesElectrical
CertificationCE
OriginMainland China
Digital Channels2
Bandwidth40MHz / 70MHz (model dependent)
Real Time Sampling Rate1GSa/S
Max Waveform Capture Rate30,000wfm/s
Display Resolution320*240 Pixels
Battery IncludedYes
Battery DemountableNo
Oscilloscope Sampling Rate250MSa/s or 125MSa/s
Oscilloscope Vertical Resolution10mV to 10V
Oscilloscope Horizontal Resolution50ns/div
Multimeter Counts4000 counts
Multimeter FunctionsAC/DC voltage, AC/DC current, Resistance, Diode testing, Capacitance, Continuity test
AWG Sampling Rate250MSa/s
AWG Vertical Resolution12-bits
AWG Waveform Types & FrequenciesSine: 1Hz to 25MHz, Square: 1Hz to 10MHz, Triangular: 1Hz to 1MHz, Trapezoid: 1Hz to 5MHz
AWG Output Impedance50 Ohm

8. User Tips

  • Always start with the 'Auto' button in oscilloscope mode for a quick initial setup, then fine-tune the settings manually.
  • When measuring small signals, ensure proper grounding to minimize noise interference.
  • For accurate multimeter readings, ensure good contact between the test leads and the component.
  • Familiarize yourself with the button layout and menu structure to efficiently switch between functions.

9. Warranty and Support

For detailed warranty information, technical support, or service inquiries, please refer to the official Hantek documentation or contact your point of purchase.

A comprehensive user manual in PDF format is available for download. You can access it via this link: Hantek Digital Oscilloscope User Manual (PDF).

For European customers, the authorized representative is:

MJCM SARL
78 avenue des Champs-Élysées Bureau 326
Email: mjcm190928@gmail.com
Phone: +33 0767213611

© 2024 Hantek. All rights reserved.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.

After a successful submission, we securely hash the supplied account or form email before sending it to Microsoft Advertising for conversion attribution. Privacy details.