1. Introduction
This device is an intelligent balancing protection board designed specifically for 6S-10S series lithium batteries, supporting ternary lithium/lithium iron phosphate batteries. Its main advantages include protecting the battery from overcharging, over-discharging, over-current, over-temperature, and short-circuit. It also provides balanced charging to achieve long-term maintenance of the battery through voltage balancing, thereby extending the service life of the battery pack.
The BMS is suitable for series-connected lithium battery packs. Once an individual cell voltage reaches the equilibrium turn-on voltage, the high voltage battery will be balanced until the equilibrium release voltage is reached.
2. Product Overview
Video: Overview of the Heltecbms manufacturing and testing process.

Image: Heltecbms 8S 30A and 60A 3.2V BMS boards with balance wires.
Product Model Selection
The currently available models are listed below. Customization for 6-10S series is supported.
| Parameter | Value |
|---|---|
| Number of strings | 6S-10S |
| Current | 30A/60A |
| Applicable battery | NCM/LFP |
Product Model Description Example
Using a 30A protective board with 10 strings as an example:
- HT-610 LOS 10S 30A
- HT-610 LPS 8S 30A
Decoding the model number:
- 610: Indicates this series can produce 6 to 10 strings.
- LOS: Indicated for NCM battery (Ternary Lithium).
- LPS: Indicated for LFP battery (Lithium Iron Phosphate).
- 10S: The number of strings of this BMS board.
- 30A: The discharge current of this BMS board.
3. Specifications
General Product Properties
- High-concerned chemical: None
- Balance Function: Passive Balanced BMS
- Type: LI-ION Battery BMS
- Function: Overcharge Protection, Over Discharge Protection
- Feature1: Factory direct sale bms
- Feature2: ebike bms
- Certification: CE
- Handware or Smart: Handware BMS
- Charge and Discharge Port: Common Port BMS
- Usage Scenario: Power BMS, Energy Storage BMS
Lithium Iron Phosphate (LiFePO4) Parameters
Test conditions: room temperature 25°C. The over-current value and internal resistance are dynamic parameters. The voltage of each battery cell needs to be ≥ 3.25 V during testing.
| Project | Symbol | Detailed Content | Standard |
|---|---|---|---|
| Serial number | S | Number of battery strings | 8S |
| Current that the shield can withstand | A | 30/60A | |
| Battery type | Ternary lithium / lithium iron phosphate | lithium iron phosphate | |
| Overcharge detection voltage | VDET1 | 3.65V±0.035V | |
| Overcharge detection delay time | tVDET1 | 1.3s (MAX) | |
| Overcharge relieve voltage | VREL1 | 3.55V±0.025V | |
| Over discharge test voltage | VDET2 | 2.350V±0.025V | |
| Delay time for over discharge detection | tVDET2 | 1.5s (MAX) | |
| Over discharge relieve voltage | VREL2 | 2.55V±0.025V relieve | |
| Discharge over-current detection voltage | VDET3 | 21mV±5mV | |
| Instantaneous single pulse current (30A continuous) | IDP | Theoretical value (battery voltage=3.6V, MOSFET temp 20-45°C) | 200A |
| Instantaneous single pulse current (60A continuous) | IDP | Theoretical value (battery voltage=3.6V, MOSFET temp 20-45°C) | 400A |
| Instantaneous multi-pulse current (30A continuous) | IDp | 120A | |
| Instantaneous multi-pulse current (60A continuous) | IDp | 240A | |
| Duration | 6-10s | ||
| Protection release condition | Break short circuit | ||
| Short-circuit protection conditions | External load circuit short circuit | ||
| Detection delay time | TSHORT | 300µS (MAX) | |
| Protection release conditions | Break short circuit | ||
| Main circuit on state resistance (battery voltage=3.4V) | RDS | B- to P- RDS≤1.2/0.8mΩ | |
| Internal consumption of the circuit during operation | IDD | MIN: 0.3µA MAX: 100µA | |
| Electricity balance detection voltage | VBU | 3.45V±0.035V | |
| Balance startup delay time | tVBU | 1.6S (MAX) | |
| Battery balance release voltage | VBL | 3.44V±0.035V | |
| 3.45V battery balance current | IB | 67mA±5mA | |
| Over-temperature protection (Charging optional) | Low temperature -0°C± 5°C | No | |
| MAX continuous working current (Charge) | The rated current of the charger when charging the battery pack | 30A/60A (Equivalent to A of the protective board) | |
| MAX continuous working current (Discharge) | The rated current of the battery pack when discharging the load | 30A/60A (Equivalent to A of the protective board) | |
| Charger selection | Voltage=Number of strings × 3.65V ± 0.05V | 30A/60A (Equivalent to A of the protective board) | |
| Charging MOS MAX withstand voltage | VDS | DC 42V |
Ternary Lithium Parameters
Test conditions: room temperature 25°C. The over-current value and internal resistance are dynamic parameters. The voltage of each battery cell needs to be ≥ 3.6 V during testing.
| Project | Symbol | Detailed Content | Standard |
|---|---|---|---|
| Serial number | S | Number of battery strings | 6S/7S/10S |
| Current | A | Max continuous current | 30/60A |
| Battery type | Ternary lithium / lithium iron phosphate | Ternary lithium | |
| Overcharge detection voltage | VDET1 | 4.25V±0.035V | |
| Overcharge detection delay time | tVDET1 | 1.3s (MAX) | |
| Overcharge relieve voltage | VREL1 | 4.19V±0.025V | |
| Over discharge test voltage | VDET2 | 2.8V±0.025V | |
| Delay time for over discharge detection | tVDET2 | 1.5s (MAX) | |
| Over discharge relieve voltage | VREL2 | 3.0V±0.025V relieve | |
| Discharge over-current detection voltage | VDET3 | 21mV±5mV | |
| Instantaneous single pulse current (30A continuous) | IDP | Theoretical value (battery voltage=3.6V, MOSFET temp 20-45°C) | 200A |
| Instantaneous single pulse current (60A continuous) | IDP | Theoretical value (battery voltage=3.6V, MOSFET temp 20-45°C) | 400A |
| Instantaneous multi-pulse current (30A continuous) | IDp | 120A | |
| Instantaneous multi-pulse current (60A continuous) | IDp | 240A | |
| Duration | 5-10s | ||
| Protection release condition | Break short circuit | ||
| Short-circuit protection conditions | External load circuit short circuit | ||
| Detection delay time | TSHORT | 300µS (MAX) | |
| Protection release conditions | Break short circuit | ||
| Main circuit on state resistance (battery voltage=3.4V) | RDS | B- to P- RDS≤1.2/0.8mΩ | |
| Internal consumption of the circuit during operation | IDD | MIN: 0.3µA MAX: 100µA | |
| Electricity balance detection voltage | VBU | 4.2V±0.035V | |
| Balance startup delay time | tVBU | 1.6S (MAX) | |
| Battery balance release voltage | VBL | 4.19V±0.035V | |
| 3.59V battery balance current | IB | 90mA±5mA | |
| Over-temperature protection (Charging optional) | High temperature 75°C± 5°C | NO | |
| MAX continuous working current (Charge) | The rated current of the charger when charging the battery pack | 30A/60A (Equivalent to A of the protective board) | |
| MAX continuous working current (Discharge) | The rated current of the battery pack when discharging the load | 30A/60A (Equivalent to A of the protective board) | |
| Charger selection | Voltage=Number of strings × 3.65V ± 0.05V | 30A/60A (Equivalent to A of the protective board) | |
| Charging MOS MAX withstand voltage | VDS | MAX voltage value that the charger can withstand when the charging port is connected | DC 42V |
4. Dimensions
The length and width of the 6-10S series protection board are consistent, while the thickness varies according to the current rating.

Image: Diagram showing the 63mm x 48mm dimensions and a table indicating thickness (5.5mm for 30A, 9mm for 60A).