1. Product Overview
The ATORCH KWS-303WF is a multifunction WiFi Din Rail AC Monitor designed to measure and display various electrical parameters including voltage, current, active power, electric energy (KWh), power factor, and frequency. It also features temperature monitoring and comprehensive safety protections, all accessible via a mobile application.
Figure 1: ATORCH KWS-303WF Device and Mobile App Interface
This image shows the KWS-303WF meter with its integrated display, a connected temperature probe, and a smartphone displaying the associated mobile application. The app interface shows real-time readings for voltage, current, power, energy, power factor, frequency, and temperature, along with settings for over-voltage, low-voltage, over-current, over-power, over-energy, and over-temperature limits.
Key Features:
- Real-time monitoring of Voltage, Current, Power, Energy (KWh), Power Factor, Frequency, and Temperature.
- WiFi connectivity for remote monitoring and control via Smart Life or Tuya Smart App.
- Comprehensive protection functions: Over-voltage, Under-voltage, Over-current, Over-power, Over-energy, and Over-temperature.
- Timer switch functionality via the mobile app.
- Din Rail mounting for easy installation in electrical panels.
2. Safety Precautions
Please read and understand all instructions before installation and operation. Failure to follow these instructions may result in electric shock, fire, or serious injury.
- This product is suitable for indoor use only.
- This product is designed for AC power systems.
- During installation, always disconnect the main power supply to avoid the risk of electric shock.
- Ensure all wiring is connected correctly and securely according to the provided diagrams.
- Do not exceed the specified measurement ranges for current and voltage (AC 85-290V, 0-40A).
- Do not use tools to disassemble the device or alter its internal wiring unless you are a qualified professional.
- If the product exhibits any abnormal behavior, discontinue use immediately and consult a qualified electrician.
Figure 2: Six Major Safety Protection Functions
This diagram visually represents the six integrated safety protection features: Over Voltage (Over V), Low Voltage (Low V), Over Current (Over I), Over Power (Over P), Over Energy (Over E), and Over Temperature (Over T). These functions provide comprehensive electrical safety protection.
3. Setup Instructions
3.1 Package Contents
- ATORCH KWS-303WF WiFi Din Rail AC Monitor
- Temperature Probe (NTC sensor)
- User Manual (this document)
3.2 Wiring Diagram
Ensure the main power supply is OFF before proceeding with wiring. Connect the device according to the diagram below. The 'N' terminal is for Neutral, and 'L' terminal is for Live.
Figure 3: KWS-303WF Wiring Diagram
This diagram illustrates the correct wiring for the KWS-303WF. The input (top terminals) and output (bottom terminals) connections for both Neutral (N) and Live (L) wires are shown. The device is installed in series with the load. The temperature probe connects to the NTC terminals at the bottom.
Figure 4: Example Wiring Setup
This image provides a practical example of the KWS-303WF wiring. It shows the meter connected in series between a household leakage switch and an electric sub-control switch, which then powers a light bulb. Red wires indicate Live (L) and blue wires indicate Neutral (N).
3.3 Mobile App Installation
- Download the