1. Introduction
This manual provides essential information for the safe and effective operation of your PEAKMETER PM18C Digital Multimeter. Please read it thoroughly before use and keep it for future reference.

Figure 1: PEAKMETER PM18C Digital Multimeter highlighting key features like True RMS, 100,000uF capacitor measurement, flashlight/backlight, live wire detection, and overload protection.
2. Safety Information
This digital multimeter complies with IEC-61010 safety requirements for electronic measuring instruments and hand-held digital multimeters. It meets IEC-61010 requirements for 600V CAT IV, 1000V CAT III, and pollution degree 2.
2.1 Safety Instructions
- Always observe standard safety procedures against electric shock and unintended use.
- Use only the provided test leads and ensure they are flawless before operation.
- Do not operate the meter if its appearance or test leads are damaged.
- The safety function of the meter will be nullified if not properly operated.
- Operate with extreme care near exposed conductors or bus lines.
- Do not use in the vicinity of explosive gases, vapors, or dust.
- Ensure measurements are made with correct input terminals, functions, and within the allowable measuring range.
- Input values must not exceed the maximum limits for each measuring range.
- Avoid touching unused input terminals when connected to a live circuit.
- Exercise caution to avoid electric shock when measuring voltages exceeding 60V DC or 30V AC (valid value).
- When using test leads, keep fingers behind the protective rings.
- Disconnect test leads from the circuit before switching measuring ranges.
- For DC functions, always check for the absence of AC voltage first using AC functions to prevent electric shock from incorrect readings.
- Before resistance, diode, capacitor, or continuity tests, disconnect power and discharge high-voltage capacitors in the circuit.
- Do not perform resistance or continuity tests on live circuits.
- Before current measurement, check the meter's protective fuse and power off the circuit to be measured.
- When repairing TVs or measuring power switching circuits, prevent high amplitude voltage impulses from damaging the meter.
- The meter uses 4 x 1.5V AA batteries. Replace them immediately when the battery low indicator ([battery icon]) appears to prevent incorrect readings and potential electric shock.
- Category III voltage must not exceed 1000V, and Category IV voltage must not exceed 600V.
- Do not use the meter if its case (or part of it) is dismantled.
2.2 Safety Symbols
| Symbol | Description |
|---|---|
| ⚠ | Warning: Consult operation manual before use. |
| ∿ | AC (alternating current) |
| — | DC (direct current) |
| ≈ | AC/DC |
| ⊥ | Ground |
| □ | Double insulation protection |
| ⚡ | High voltage warning |
| CE | Compliant with European Union Directive |
| CAT III 1000V | Over-voltage protection (Category III, 1000 Volts) |
| CAT IV 600V | Over-voltage protection (Category IV, 600 Volts) |
3. Setup and Overview
3.1 Unpacking and Accessories
Carefully unpack your multimeter and check for the following items:
- PEAKMETER PM18C Digital Multimeter
- Test Leads (one pair)
- K-Type Thermocouple (for models with temperature measurement)
- User Manual (this document)

Figure 2: The PEAKMETER PM18C Multimeter shown with its standard accessories: user manual, temperature probe, and test leads.
3.2 Battery Installation
The meter uses 4 x 1.5V AA batteries. To install or replace batteries:
- Ensure the meter is powered off and all test leads are disconnected from input sockets and any circuit.
- Use a screwdriver to unscrew the bolts securing the battery cover on the back of the meter.
- Remove the battery cover.
- Insert new 4 x 1.5V AA batteries, observing correct polarity.
- Replace the battery cover and secure it with the screws.

Figure 3: Rear view of the multimeter with the battery cover open, showing the three AAA battery slots. Note: The manual states 4xAA, but the image shows 3xAAA. Follow the manual's text for battery type.
Note: The manual specifies 4x 1.5V AA batteries, while the image shows 3x AAA batteries. Please refer to the physical product for the correct battery type and quantity.
3.3 Meter Components Overview
Familiarize yourself with the main parts of your multimeter:

Figure 4: Front view of the multimeter, highlighting its True RMS measurement, 6000 counts display, live wire detection, capacitance measurement up to 100,000 µF, NCV electric field sensing, and Celsius/Fahrenheit measurement capabilities.
- Non-contact voltage detection area: Top part of the meter for NCV.
- Non-contact voltage indicator: LED indicator for NCV detection.
- LCD screen: Large display for readings, symbols, and indicators.
- HFE test jack: Sockets for transistor testing.
- Keys:
- SEL (Select) key: Toggles between functions within a rotary switch position (e.g., °C/°F, Hz/%, AC V/Hz).
- HOLD key: Freezes the current reading on the display. Press again to release.
- Backlight/Flashlight key: Press and hold for 5 seconds to turn on/off backlight and flashlight. Automatically turns off after 15 seconds if not pressed again.
- Rotary switch: Selects the desired measurement function (e.g., V~, V-, Ω, A~, A-, NCV, etc.).
- Input sockets:
- COM: Common negative input terminal (for black test lead).
- VΩHz%Lives: Positive input for Voltage, Resistance, Frequency, Duty Cycle, Diode, Continuity, Temperature, and Live Line (for red test lead).
- µA mA: Positive input for microampere and milliampere current measurements (for red test lead).
- 20A: Positive input for high current (up to 20A) measurements (for red test lead).

Figure 5: The multimeter is shown alongside its soft orange rubber cover, which provides secondary insulation and protection against drops and impacts.
4. Operational Guidelines
4.1 Normal Operation
- Hold Mode: Press the "HOLD" key to freeze the current reading on the LCD. Press it again to release and resume live readings.
- Backlight & Lighting: Press and hold the backlight key for over 5 seconds to activate the backlight and flashlight. Press and hold again for 5 seconds to manually disable them. They will automatically turn off after 15 seconds of inactivity.
- Auto Power Off: If no operation is performed for 15 minutes, the meter will beep and automatically power off to save battery. Press any key to restart.
4.2 Measurement Guidelines
Important Safety Note: Always ensure the circuit under test is de-energized and high-voltage capacitors are discharged before performing resistance, diode, continuity, or capacitance measurements. Never attempt to measure voltage or current beyond the specified maximum limits.
4.2.1 AC and DC Voltage Measurement (V~ / V-)
- Turn the rotary switch to the V~ (AC Voltage) or V- (DC Voltage) position.
- Connect the black test lead to the COM input socket and the red test lead to the VΩHz%Lives input socket.
- Connect the test leads across the circuit or component to be measured (in parallel).
- Read the voltage value on the LCD screen. For DC voltage, the polarity will be indicated.
- Press the SEL key in AC voltage mode to measure frequency.
4.2.2 Electric Resistance Measurement (Ω)
- Turn the rotary switch to the Ω position.
- Connect the black test lead to COM and the red test lead to VΩHz%Lives.
- Connect the test leads across the component to be measured.
- Read the resistance value on the LCD screen. "OL" indicates an open circuit or resistance beyond range.
4.2.3 Diode Test (→|-)
- Turn the rotary switch to the →|- position.
- Connect the black test lead to COM and the red test lead to VΩHz%Lives.
- Connect the red test lead to the anode and the black test lead to the cathode of the diode.
- The meter will display the forward voltage drop. Reverse the leads to check for "OL" (open circuit) for a good diode.
4.2.4 Beep Continuity Test (♫)
- Turn the rotary switch to the ♫ position.
- Connect the black test lead to COM and the red test lead to VΩHz%Lives.
- Connect the test leads across the circuit or component.
- If resistance is less than approximately 40Ω, the beeper will sound continuously, and a green LED will illuminate. Between 40Ω and 60Ω, a red LED will illuminate.
4.2.5 Capacitance Measurement (F)
- Turn the rotary switch to the F position.
- Connect the black test lead to COM and the red test lead to VΩHz%Lives.
- Connect the test leads across the capacitor (observe polarity for electrolytic capacitors).
- Read the capacitance value on the LCD screen. Large capacitance measurements may take time to stabilize.
4.2.6 Transistor Measurement (hFE)
- Turn the rotary switch to the hFE position.
- Determine if the transistor is NPN or PNP.
- Insert the emitter (e), base (b), and collector (c) pins of the transistor into the corresponding holes in the HFE test jack.
- Read the approximate hFE value on the LCD screen.
4.2.7 Frequency Measurement (Hz%)
- Turn the rotary switch to the Hz% position.
- Connect the black test lead to COM and the red test lead to VΩHz%Lives.
- Connect the test leads across the circuit to measure frequency.
- Read the frequency value on the LCD screen.
4.2.8 AC and DC Current Measurement (A~ / A-)
- Turn the rotary switch to the appropriate A~ (AC Current) or A- (DC Current) range (µA, mA, or 20A).
- Connect the black test lead to COM.
- Connect the red test lead to the µA mA socket for currents up to 600mA, or to the 20A socket for currents up to 20A.
- Important: Connect the meter in series with the circuit to be measured. Break the circuit and insert the meter.
- Read the current value on the LCD screen. "OL" indicates current beyond range.

Figure 6: The multimeter is shown connected in series with a light bulb to measure current, displaying a reading of 0.143 mA AC.
4.2.9 Non-Contact Voltage (NCV) Detection
- Turn the rotary switch to the NCV position.
- Place the top of the meter near a conductor.
- If AC voltage is detected, signal density indicators (high, medium, low) will illuminate, and the beeper will sound at different frequencies.

Figure 7: The multimeter is positioned near a wall outlet, demonstrating its Non-Contact Voltage (NCV) detection capability. The display shows indicators for voltage presence.
4.2.10 Live Line Test (Live)
- Turn the rotary switch to the Live position.
- Connect the red test lead to the VΩHz%Lives input socket.
- Insert the red test lead into the "L" (Live) jack of a power socket or approach a live conductor.
- If AC voltage is detected, the meter's intensity indicator (high, medium, low) will illuminate, and the beeper will sound.
4.2.11 Temperature Measurement (°C / °F)
(Only for models equipped with this function)
- Turn the rotary switch to the °C / °F position.
- Insert the red plug of the K-type thermocouple into the VΩHz%Lives input socket and the black plug into the COM input socket.
- Place the thermocouple tip on or near the object whose temperature is to be measured.
- Read the temperature value on the LCD screen after it stabilizes.
5. Maintenance
5.1 General Maintenance and Cleaning
Warning: To avoid electric shock or damage, always disconnect test leads from input signals and power off the meter before cleaning or opening the case/battery cover. Do not attempt to clean the inside of the meter.
- Regularly clean the meter's shell with a damp cloth and a small amount of mild detergent. Do not use abrasives or chemical solvents.
- Dirty or damp input sockets can affect readings. To clean input sockets:
- Power off the meter and remove all test leads.
- Clean any dirty substances from the sockets.
- Use a new cotton ball with detergent or lubricant to clean each socket.
5.2 Battery and Fuse Replacement
Warning: To avoid electric shock or personal injury, replace batteries when the low battery symbol appears. Only use designated fuses (630mA/250V and 20A/250V quick-acting fuses). Ensure the device is powered off and test leads are disconnected from the circuit before opening the battery cover.
- Power off the meter.
- Remove all test leads from the input sockets.
- Use a screwdriver to unscrew the bolts securing the battery cover.
- Remove the battery cover.
- Remove old batteries or damaged protective fuses.
- Replace with new 4 x 1.5V AA batteries (observing polarity) or new protective fuses.
- Remount the battery cover and secure it with the screws.
6. Troubleshooting
This section addresses common issues you might encounter:
- "OL" displayed: Indicates an overload, out-of-range measurement, or an open circuit. Check your range selection and connections.
- Low Battery Indicator: If the battery symbol appears on the display, replace the batteries immediately to ensure accurate readings and proper operation.
- Unstable Readings: Strong electromagnetic interference can cause unstable readings. Move away from such sources if possible.
- No Display/Meter Not Turning On: Check battery installation and charge. Ensure the rotary switch is set to an ON position.
If you encounter persistent issues not covered here, consult a qualified technician.
7. Technical Specifications
7.1 Overall Parameters
- Operating Environment: 600V CAT IV and 1000V CAT III, Pollution level 2, Altitude < 2000m
- Working Temperature & Humidity: 0~40°C (relative humidity < 80%, < 70% below 10°C)
- Storage Temperature & Humidity: -10~60°C (batteries removed when RH < 70%)
- Coefficient of Temperature: 0.1 x accuracy/°C (<18°C or >28°C)
- Allowable Max Voltage (terminal to ground): 1000V DC or 750V AC (valid value)
- Fuse Protection: mA position: FF 630mA/250V; A position: FF 20A/250V
- Rotation Rate: Approximately 3 revolutions/second
- Display Unit: 6000 counts LCD, automatic unit display
- Outrange Indication: "OL" on LCD
- Low Battery Indication: Battery symbol appears
- Input Polarity Indication: "-" automatically appears
- Power: 4 x 1.5V AA battery
- Dimensions: 190mm (L) x 89mm (W) x 50mm (H)
- Weight: Approximately 380g (inclusive of batteries)
7.2 Precision Indicator
Accuracy: ±(% reading + digit). Warranty for 1 year from ex-factory date. Reference conditions: 18°C to 28°C, relative humidity ≤ 80%.
7.2.1 DC Voltage
| Range | Resolution | Accuracy |
|---|---|---|
| 600mV | 0.1mV | ±(0.5% Reading + 3 digits) |
| 6V | 1mV | |
| 60V | 10mV | |
| 600V | 100mV | |
| 1000V | 1V | ±(0.5% Reading + 3 digits) |
Input Impedance: 10MΩ. Max Input Voltage: 1000V DC or 750V AC (valid value).
7.2.2 AC Voltage
| Range | Resolution | Accuracy |
|---|---|---|
| 6V | 1mV | ±(0.8% readings + 3 digits) |
| 60V | 10mV | |
| 600V | 100mV | |
| 750V | 1V | ±(1% readings + 10 digits) |
Input Impedance: 10MΩ. Max Input Voltage: 1000V DC or 750V AC (valid value). Frequency Response: 40Hz-1kHz True RMS.
7.2.3 Frequency
| Range | Resolution | Accuracy |
|---|---|---|
| 9.999Hz | 0.001Hz | ±(1% Reading + 3 digits) |
| 99.99Hz | 0.01Hz | |
| 999.9Hz | 0.1Hz | |
| 9.999KHz | 0.001 KHz | |
| 99.99KHz | 0.01 KHz | |
| 999.9KHz | 0.1 KHz | |
| 9.999MHz | 0.001MHz |
Input Voltage Range: 200mV-10V AC (valid value). Overload Protection: 600V DC/AC.
7.2.4 Electric Resistance
| Range | Resolution | Accuracy |
|---|---|---|
| 600Ω | 0.1Ω | ±(0.8% Reading + 3 digits) |
| 6KΩ | 1Ω | |
| 60KΩ | 10Ω | |
| 600KΩ | 100Ω | |
| 6MΩ | 1KΩ | ±(1.2% Reading + 30 digits) |
| 60MΩ | 10KΩ |
Overload Protection: 600V DC/AC. Open-circuit Voltage: 1V.
7.2.5 Diode Test
| Range | Resolution | Testing Conditions |
|---|---|---|
| 0-3V | 0.001V | Forward DC current: approx. 1mA; Open-circuit voltage: approx. 3.2V. Displays approx. diode forward voltage drop. |
Overload Protection: 600V DC/AC.
7.2.6 Beeper Continuity
| Range | Resolution | Description |
|---|---|---|
| 600Ω | 0.1Ω | Beeper sounds and green indicator on if resistance < 30Ω. Red indicator on if resistance 40Ω-60Ω. Open-circuit voltage: approx. 1V. |
Overload Protection: 600V DC/AC.
7.2.7 Transistor (hFE)
| Range | Testing Conditions |
|---|---|
| 0-1000 | Base current: approx. 10µA; Vce: approx. 2.8V. |
7.2.8 Capacitor
| Range | Resolution | Accuracy |
|---|---|---|
| 6nF | 0.001nF | ±(4.0% Reading + 30 digits) |
| 60nF | 0.01nF | ±(4.0% Reading + 3 digits) |
| 600nF | 0.1nF | |
| 6µF | 1nF | |
| 60µF | 10nF | |
| 600µF | 100nF | |
| 6mF | 1µF | |
| 100mF | 0.01mF | ±(5.0% Reading + 3 digits) |
Overload Protection: 600V DC/AC.
7.2.9 DC Current
| Range | Resolution | Accuracy |
|---|---|---|
| 60µA | 0.01µA | ±(0.8% Reading + 3 digits) |
| 60mA | 0.01mA | |
| 600mA | 0.1mA | |
| 20.00A | 10mA | ±(1.2% Reading + 3 digits) |
Overload Protection: Fuse FF630mA/250V (mA range), Fuse FF20A/250V (20A range). Max Input Voltage: 600mA DC/AC (mA range), 20A DC/AC (20A range). Continuous measurement >5A for max 10 seconds. Allow 1 minute rest after previous measurement.
7.2.10 AC Current
| Range | Resolution | Accuracy |
|---|---|---|
| 60mA | 0.01mA | ±(1% Reading + 3 digits) |
| 600mA | 0.1mA | |
| 20A | 10mA | ±(1.5% Reading + 3 digits) |
Overload Protection: Fuse FF630mA/250V (mA range), Fuse FF20A/250V (20A range). Max Input Voltage: 600mA DC/AC (mA range), 20A DC/AC (20A range). Continuous measurement >5A for max 15 seconds. Allow 1 minute rest after previous measurement. Frequency Response: 40Hz-1kHz True RMS.
7.2.11 Temperature
| Range | Resolution | Accuracy |
|---|---|---|
| -20°C ~ 1000°C | 1°C | ±(1.0% + 3) reading |
| -4°F ~ 1832°F | 1°F | ±(1.0% + 3) reading |
Overload Protection: 600V DC/AC.
8. User Tips
- Always Double-Check Connections: Before taking any measurement, ensure your test leads are correctly plugged into the appropriate input jacks for the function you've selected on the rotary dial.
- Start with Higher Ranges: When measuring an unknown voltage or current, it's safer to start with the highest range setting and then decrease it if necessary for a more precise reading.
- Keep Test Leads Organized: Tangled test leads can be a safety hazard. Keep them neatly coiled when not in use.
- Protective Cover: Always use the provided rubber protective cover to shield your multimeter from accidental drops and impacts.
- Practice Safe Habits: When working with electricity, always follow lockout/tagout procedures, wear appropriate personal protective equipment (PPE), and work with a partner if possible.
9. Warranty and Support
Warranty information for this product was not provided in the source materials. Please refer to your purchase documentation or contact the seller for details regarding warranty coverage and technical support.