1. Product Introduction
The Heltecbms HT-616L Series is an intelligent balancing protection board designed for 6S-16S series lithium batteries, supporting both ternary lithium (NCM) and lithium iron phosphate (LFP) battery types. This device provides essential protection and management functions to ensure the longevity and safe operation of your battery pack.
Key Features:
- Overcharge Protection: Prevents batteries from being charged beyond their safe voltage limit.
- Over-discharge Protection: Safeguards batteries from discharging below their minimum safe voltage.
- Over-current Protection: Protects against excessive current draw during operation.
- Over-temperature Protection: Monitors and prevents the battery from operating at unsafe temperatures.
- Short Circuit Protection: Instantly cuts off power in case of a short circuit.
- Balanced Charging: Actively balances individual cell voltages to maintain battery health and extend service life.
The BMS is suitable for series-connected lithium battery packs. It initiates balancing when an individual cell voltage reaches the equilibrium turn-on voltage and continues until the equilibrium release voltage is achieved.
2. Product Model Description
The model numbers for the HT-616L series follow a specific naming convention to indicate their specifications. For example, a 50A protective board with 12 strings can be described as:
- HT-616 LOS 12S 50A
- HT-616 LPS 12S 50A
Where:
- 616: Refers to the series, capable of supporting 6 to 16 strings.
- LOS: Indicates the BMS is designed for NCM (Ternary Lithium) batteries.
- LPS: Indicates the BMS is designed for LFP (Lithium Iron Phosphate) batteries.
- 12S: Represents the number of series strings the BMS board supports (e.g., 12 strings).
- 50A: Denotes the maximum continuous discharge current of the BMS board.
The available models support 6S-16S configurations with current ratings of 30A, 50A, or 80A.
3. Setup and Installation
Proper installation is crucial for the safe and effective operation of your BMS. Please follow these instructions carefully.
Package Contents:
The product package typically includes the BMS board and a collection line (balance wire harness).
Image: Two Heltecbms 13S BMS boards (40A and 60A versions) showing their labels and the balance wire harness. The image also highlights peak current (120A/180A) and balance current (100mA) specifications.
Wiring Diagram:
The following diagram illustrates the general wiring for a 13S configuration. Ensure all connections are secure and correct before applying power.
Image: A detailed wiring diagram showing how to connect a 13S BMS board to individual battery cells (1 through 13) and the main battery terminals (B- and P-). The balance wires are connected to each cell, and the main power wires are connected to the battery pack and the load/charger.
Important: The BMS boards are designed for a 'Same Port' connection, meaning the charge and discharge current share the same main terminals (P-).
After wiring, the protection board must be activated by connecting a charger to the battery pack. Measure the voltage of each battery cell separately to ensure they are within the safe operating range before initial use.
4. Operating Instructions
Once installed and activated, the BMS continuously monitors the battery pack to ensure safe operation. The primary function is automatic protection and balancing.
Battery Types and Voltage Requirements:
- Ternary Lithium (NCM) Batteries: Each cell voltage needs to be ≥ 3.7V during testing.
- Lithium Iron Phosphate (LFP) Batteries: Each cell voltage needs to be ≥ 3.25V during testing.
The BMS will automatically engage its protection features if any parameter (voltage, current, temperature) exceeds the predefined limits. It will also perform passive balancing to equalize cell voltages, extending the overall life of the battery pack.
5. Maintenance
The Heltecbms HT-616L series BMS is designed for low maintenance. However, regular checks can help ensure optimal performance and longevity.
General Maintenance Tips:
- Visual Inspection: Periodically inspect the BMS board and wiring for any signs of damage, loose connections, or corrosion.
- Environmental Conditions: Ensure the BMS operates within its specified temperature range. Avoid exposure to excessive moisture or extreme temperatures.
- Battery Health: While the BMS balances cells, it's good practice to monitor the overall health of your battery pack. If individual cell voltages consistently deviate significantly, it may indicate an issue with a cell or the balance function.
Battery Balance:
The BMS features passive balancing. For LFP batteries, balancing starts when the electricity balance detection voltage reaches 3.405V ± 0.035V, with a startup delay of 1.6 seconds (MAX). For NCM batteries, balancing starts when the electricity balance detection voltage reaches 4.22V ± 0.035V, with a startup delay of 1.6 seconds (MAX). The balance current is approximately 100mA ± 5mA.
6. Troubleshooting
This section provides guidance on common issues and their solutions. For complex problems, please refer to the full user manual PDF or contact customer support.
| Fault Phenomenon | Fault Inspection and Cause | Processing Method |
|---|---|---|
| Can't discharge | First, connect the circuit to activate the protection board for charging, and then measure the voltage of each battery separately. If the voltage of any battery is lower than 3.0V±0.025V (NCM) / 2.35V±0.025V (LFP), the protection board will start over-discharge protection. | If the battery is lower than 3.0V, please charge the battery to 3.7V (NCM) / 3.25V (LFP) and balance it before combining. Do not mix good batteries with poor batteries. If the problem persists, contact after-sales service. |
| Can't charge | Measure the voltage of each battery section. If any battery voltage is higher than 4.215V (NCM) / 3.615V (LFP) or so, the protection board will start overcharge protection. | If the battery is higher than 4.215V (NCM) / 3.615V (LFP), please discharge the battery to about 3.7V until it is balanced before combining. Do not mix good batteries with poor batteries. If the problem persists, contact after-sales service. |
| Charging/discharge failure | B-, B1, B2, B3,... B+ Wrong wiring. | Redraw the wiring or operate under the guidance of customer service. |
| Overcharge/discharge protection is invalid | B-, B1, B2, B3,... B+ Wrong wiring. | Redraw the wiring or operate under the guidance of customer service. |
| Discharge protection | Check whether the current value of the load starting power supply exceeds the over-current protection current of the protection board. | Replace the protection board with a larger current (if not solved, please contact after-sales). |
| Component is welded loosely | One of the components has a pin that is not connected to the PCB pad. | You can repair the welding by yourself (if it still cannot be solved, please contact after-sales). |
| Component welding | There is a short circuit between two or more pins of the element. | Remove the component and re-weld (if not, please contact after-sales). |
| Electrostatic breakdown | When the MOS tube is not powered, the forward and reverse resistance of any two pins of the G, D and S terminals are 0. | You can remove and replace the MOS tube by yourself (if it still cannot be solved, please contact after-sales). |
7. Specifications
General Parameters:
- Number of Strings: 6S-16S
- Charging Current: 40A (for 40A model), 60A (for 60A model)
- Usage Scenario: Power BMS, Energy Storage BMS
- Certification: CE
- Balance Function: Passive Balanced BMS
- Type: LI-ION Battery BMS (Hardware BMS)
- Charge and Discharge Port: Common Port BMS
- Functions: Overcharge Protection, Over Discharge Protection, Overcurrent Protection
Physical Dimensions:
The length and width of the 6-16S series protection board are consistent. The thickness varies based on the current rating.
| Dimension | Value |
|---|---|
| Length | 70mm (approx.) |
| Width | 55mm (approx.) |
| Current | Thickness (MM) |
|---|---|
| 30A | 8 |
| 50A/80A | 12 |
Detailed Protection Parameters (LFP - Lithium Iron Phosphate):
Test conditions: room temperature 25°C. The over-current value and internal resistance are dynamic parameters. Voltage of each battery cell needs to be ≥ 3.25V during testing.
| Project | Symbol | Detailed Content | Standard |
|---|---|---|---|
| Current | A | Current that the shield can withstand | 30/50/80A |
| Overcharge detection voltage | VDET1 | 3.65V±0.035V | |
| Overcharge detection delay time | tVDET1 | 1.3s (MAX) | |
| Overcharge relieve voltage | VREL1 | 3.55V±0.025V | |
| Over discharge test voltage | VDET2 | 2.350V±0.025V | |
| Delay time for over discharge detection | tVDET2 | 1.5s (MAX) | |
| Over discharge relieve voltage | VREL2 | 2.55V±0.025V relieve | |
| Discharge over-current detection voltage | VDET3 | 100mV±25mV | |
| Instantaneous single pulse current (theoretical) | IDP | (Battery voltage = 3.6V, MOSFET temp 20-45°C) | 120A/200A/320A |
| Instantaneous multi-pulse current (actual) | IDp | 90A/150A/240A | |
| Duration (for current protection) | 1s | ||
| Protection release condition | Break short circuit | ||
| Short-circuit protection conditions | TSHORT | External load circuit short circuit | |
| Detection delay time (short-circuit) | 300µS (MAX) | ||
| Protection release conditions (short-circuit) | Break short circuit | ||
| Main circuit on state resistance (B- to P-) | RDS | (Battery voltage = 3.4V) | RDS ≤ 0.3mΩ |
| Internal consumption of the circuit during operation | IDD | MIN: 0.3µA MAX: 100µA | |
| Electricity balance detection voltage | VBU | 3.405V±0.035V | |
| Balance startup delay time | tVBU | 1.6S (MAX) | |
| Battery balance release voltage | VBL | 3.4V±0.035V | |
| 4.2V battery balance current | IB | 100mA±5mA | |
| Over-temperature protection (Charging optional) | Low temperature -0°C ± 5°C | No | |
| Over-temperature protection (Discharge optional) | High temperature 75°C ± 5°C | Yes | |
| MAX continuous working current (Charge) | Rated current of charger | 30A/50A/80A (Equivalent to A of the protective board) | |
| MAX continuous working current (Discharge) | Rated current of battery pack | 30A/50A/80A (Equivalent to A of the protective board) | |
| Charger selection | Voltage = Number of strings × 3.65V ± 0.05V | 30A/50A/80A (Equivalent to A of the protective board) | |
| Charging MOS MAX withstand voltage | VDS | MAX voltage value that the charger can withstand when the charging port is connected | DC 85V |
Detailed Protection Parameters (NCM - Ternary Lithium):
Test conditions: room temperature 25°C. The over-current value and internal resistance are dynamic parameters. Voltage of each battery cell needs to be ≥ 3.7V during testing.
| Project | Symbol | Detailed Content | Standard |
|---|---|---|---|
| Current | A | Max continuous current | 30/50/80A |
| Overcharge detection voltage | VDET1 | 4.25V±0.035V | |
| Overcharge detection delay time | tVDET1 | 1.3s (MAX) | |
| Overcharge relieve voltage | VREL1 | 4.2V±0.025V | |
| Over discharge test voltage | VDET2 | 2.8V±0.025V | |
| Delay time for over discharge detection | tVDET2 | 1.5s (MAX) | |
| Over discharge relieve voltage | VREL2 | 3.0V±0.025V relieve | |
| Discharge over-current detection voltage | VDET3 | 100mV±5mV |
8. User Tips
Based on common practices and troubleshooting insights:
- Initial Activation: Always remember to connect a charger to the battery pack after initial wiring to activate the BMS. This is a common step that can resolve initial non-discharge issues.
- Cell Voltage Check: Before combining batteries or troubleshooting, always measure individual cell voltages. Significant discrepancies can indicate a faulty cell or an issue with the balance wiring.
- Avoid Mixing Batteries: Do not mix good batteries with poor or damaged batteries in the same pack, as this can lead to imbalance and protection issues.
- Wiring Accuracy: Double-check all wiring connections, especially the balance wires (B1, B2, B3, etc., and B+), as incorrect wiring is a frequent cause of protection failures.
9. Warranty and Support
Warranty Regulations:
The warranty service period for this product is 1 year from the date of purchase.
The warranty service is limited to normal use. The following conditions are not covered under free warranty:
- Man-made damage.
- Self-disassembly, modification, or unauthorized repair.
- Use not in accordance with the instructions provided in this manual.
- Damage caused by external force majeure factors.
Accessories such as test fixtures are considered consumables and are not covered by warranty.
Contacting Support:
If you require warranty service, please contact your dealer for processing. If you cannot reach the dealer, you may contact Heltecbms directly via email or phone. Please note that there are no after-sales service stations outside of China. For warranty service requiring product return, you will be responsible for the round-trip shipping costs.
For a more detailed and comprehensive guide, please refer to the official user manual PDF: Heltecbms HT-616L Series User Manual (PDF)