Sunster S-AX1

Contents

Sunster 12V/24V Cool Rooftop Air Conditioner User Manual

Model: S-AX1

1. Introduction

This manual provides essential information for the safe and efficient installation, operation, and maintenance of your Sunster 12V/24V Cool Rooftop Air Conditioner. Please read this manual thoroughly before attempting to install or operate the unit. Keep this manual for future reference.

Sunster 12V/24V Cool Rooftop Air Conditioner unit, indoor panel, and remote control

Image: Sunster 12V/24V Cool Rooftop Air Conditioner unit, indoor panel, and remote control.

2. Safety Information

Always observe the following safety precautions to reduce the risk of injury or damage:

  • Ensure the power supply matches the unit's voltage requirements (12V or 24V DC).
  • Installation should be performed by qualified personnel or with careful adherence to instructions.
  • Do not attempt to modify the unit or its components.
  • Ensure proper ventilation around the outdoor unit.
  • Refrigerant handling should only be done by certified technicians.
  • Keep children away from the unit during operation and maintenance.

3. Package Contents

Upon opening the box, verify that all items are present:

Components of the Sunster RV Air Conditioner package, including the main unit, indoor panel, remote, user manual, and mounting hardware.

Image: Components of the Sunster RV Air Conditioner package.

  • Outdoor Air Conditioner Unit
  • Indoor Evaporator Control Panel
  • Remote Control
  • User Manual (PDF available online: User manual (PDF))
  • Mounting Hardware (screws, fixed splint, foam gasket, rubber pad)
  • Power Cables

4. Specifications

Feature Specification
ModelS-AX1
Nominal VoltageDC12V/24V
Rated Current (12V)50A
Rated Current (24V)35A
Maximum Current (12V)60A
Maximum Current (24V)50A
Refrigerating Capacity (12V)1800W
Refrigerating Capacity (24V)2600W
Refrigerant450g {R1234yf / R134a (Not included)}
Noise Level45 dB (A)
Air Outlets4
Minimum Skylight Size400*200mm
Internal Unit Circulating Air Volume400m³/h
Battery Requirement100Ah
Round-robin ModeInternal Circulation Mode
Driving ModeHost Driven Mode
Air Supply ModeStraight Blow Mode
Temperature Regulation ModeTemperature Regulation Mode
CertificationCE, RoHS, WEEE
OriginMainland China
Product information diagram showing dimensions and 12V/24V specifications for the air conditioner.

Image: Product information diagram showing dimensions and 12V/24V specifications.

5. Setup and Installation

The installation process involves several steps, including preparing the unit, adding refrigerant, and mounting it on your vehicle's rooftop. For a visual guide, please refer to the official installation video:

Video: Installation guide for the Sunster Rooftop Air Conditioner.

5.1. Initial Preparation

  1. Unboxing and Inventory: Open the box and carefully take an inventory of all items inside to ensure nothing is missing.
  2. Disassembly: Unscrew the screws on the outer shell of the outdoor unit and carefully take off the lid to access the internal components.

WARNING: Refrigerant handling requires specialized tools and knowledge. It is highly recommended that this step be performed by a certified professional to ensure safety and proper functioning.

The unit requires 450g of refrigerant (R1234yf or R134a, not included).

  1. Access Ports: Unscrew the light blue cover of the high-pressure tube and the low-pressure tube.
  2. Connect Fluoride Table (Manifold Gauge Set):
    • Screw the knob of the red connector to the uppermost position. Clip the red connector of the Fluoride Table onto the high-pressure interface and tighten it.
    • Screw the knob of the blue connector to the uppermost position. Clip the blue connector of the Fluoride Table onto the low-pressure interface and tighten it.
  3. Vacuum Extraction:
    • Connect the yellow connector of the Fluoride Table to a vacuum pump.
    • Turn on the vacuum pump. The vacuum pump takes about 10 minutes to extract all air from the system.
    • Check the Fluoride Table; it should show negative values.
    • Turn off the Fluoride Table switch after vacuuming.
  4. Adding Refrigerant:
    • Screw the bottle opener to the highest position. Put in the refrigerant canister and tighten it. Connect the yellow tube to the refrigerant canister.
    • Screw the bottle opener to the lowest and then to the highest position to pierce the canister and release any air in the yellow tube. Press the release valve until you see a white mist of gas spewing out, indicating air has been purged.
    • Then turn on the high-pressure switch and the low-pressure switch on the Fluoride Table to add the first can of refrigerant.
    • After adding one can of refrigerant, turn off the switch on the Fluoride Table.
    • Unscrew the yellow tube to replace the refrigerant tank. Repeat the operation for the second can.
    • Important: When adding the second bottle, you need to turn on the air conditioner power. The red high-voltage switch cannot be turned on when fluoride is added in the power-on state (it is easy to cause the pipeline to burst due to excessive pressure after opening). The second fluoride addition can only turn on the blue low-voltage switch.
  5. Disconnect: Screw the red and blue connector switch to the highest point and then remove it. Replace the light blue covers on the high and low-pressure tubes.

5.3. Unit Reassembly and Mounting

  1. Reassemble Outdoor Unit: Put on the outer shell and screw on all the screws.
  2. Measure and Cut Opening: Measure the distance for the mounting hole on your vehicle's roof. The minimum skylight size required is 400*200mm. Carefully cut out the measured spacing on the roof of the vehicle.
  3. Prepare Opening: Wipe around the cut edge to ensure it is clean and dry.
  4. Seal Opening: Fill in all holes on the rubber pad. Tear the outer membrane of the rubber pad and attach it to the cut edge of the roof opening. Fill in any gaps with waterproof sealant for a secure, watertight seal.
  5. Install Balance Screws: Screw the balance screws into the corners of the machine.
  6. Position Unit: Carefully put the outdoor unit into the hole on the roof.
  7. Adjust Balance: Use the balance screws to ensure the unit is level and stable.
  8. Connect Control Panel: Plug in the connection control panel wires from the indoor unit to the main unit.
  9. Install Fixed Splint: Install the fixed splint to secure the indoor unit.
  10. Install Foam Gasket: Insert the foam gasket into the groove with the grooved surface facing upwards.
  11. Install Indoor Panel: Align the four air vent positions on the panel with the foam gasket's grooves and insert into place. Install the control panel into its designated slot.
Sunster RV Air Conditioner installed on a rooftop.

Image: Sunster RV Air Conditioner installed on a rooftop.

Interior view of the installed Sunster RV Air Conditioner unit.

Image: Interior view of the installed Sunster RV Air Conditioner unit.

6. Operating Instructions

Your Sunster Rooftop Air Conditioner is designed for efficient and comfortable cooling. It features intelligent temperature and air speed control, allowing for cold air even during parking breaks without fuel consumption.

Interior view of an RV with a woman, highlighting intelligent temperature air speed control and benefits like no fuel consumption and no sweating.

Image: Intelligent temperature air speed control and benefits.

  • Power On/Off: Use the power button on the control panel or remote control to turn the unit on or off.
  • Temperature Adjustment: Use the 'Temp Up' and 'Temp Down' buttons to set your desired temperature.
  • Mode Selection: Cycle through available modes (e.g., Cool, Fan) using the 'Mode' button.
  • Fan Speed: Adjust the fan speed to your preference.
  • Air Outlet Adjustment: The unit features 360° adjustable air outlets for directing airflow.
  • Remote Control: The included remote control provides convenient access to all functions from a distance.
  • Long-Lasting Cooling: The unit is designed to continue working for 8-12 hours after the vehicle's engine is turned off, providing extended comfort.
  • Low Voltage Protection: The system includes low voltage protection, automatically powering off if the voltage drops below 21.3V to prevent battery damage.
Interior view of an RV with people, showing cooling capacity, low noise, intelligent frequency conversion, 360° adjustable air outlet, evaporator control panel, and easy remote control.

Image: Features including 360° adjustable air outlet, control panel, and remote control.

7. Maintenance

Regular maintenance ensures optimal performance and longevity of your air conditioner:

  • Cleaning Filters: Periodically clean the air filters on the indoor unit to maintain good airflow and cooling efficiency.
  • Exterior Cleaning: Keep the outdoor unit free from debris, leaves, and dirt. Gently wipe the exterior with a damp cloth.
  • Check Connections: Annually inspect all electrical and refrigerant connections for any signs of wear or leaks.
  • Refrigerant Level: If you notice a decrease in cooling performance, have a qualified technician check the refrigerant level.

8. Troubleshooting

If you encounter issues with your air conditioner, refer to the following common problems and solutions:

  • Unit Not Working:
    • Check power connections and ensure the unit is receiving adequate voltage.
    • Verify that the vehicle's battery meets the 100Ah requirement and is sufficiently charged.
    • Ensure the refrigerant has been properly added (450g of R1234yf / R134a).
  • Error E9 Displayed:
    • This error typically indicates a system fault. Consult the detailed user manual (PDF) for specific E9 error codes and troubleshooting steps, or contact customer support.
  • Insufficient Cooling:
    • Check if the air filters are clean and not obstructed.
    • Ensure the outdoor unit's condenser coils are clean and free of debris.
    • Verify that the refrigerant level is correct. If not, professional service is required.
    • Confirm the air outlets are not blocked and are directed appropriately.
  • Unit is Noisy:
    • Ensure the unit is securely mounted and balanced.
    • Check for any loose parts or debris inside the fan area.

9. User Tips

  • Efficient Cooling: Users report the unit is very efficient and cools well, especially in smaller spaces like industrial machinery cabins or motorhomes.
  • Installation Assistance: While installation is straightforward, some users found YouTube tutorials helpful for self-assembly.
  • Performance Metrics: When powered at maximum capacity, the unit consumes approximately 42A and can achieve an air outlet temperature of between 5 and 7 degrees Celsius.
  • Noise Level: The unit is generally considered not too noisy by users.

10. Warranty and Support

For detailed warranty information, service requests, or further technical assistance, please refer to the comprehensive user manual (PDF) provided with your product or contact your retailer. Ensure you have your product model (S-AX1) and purchase details available when seeking support.

Ask a question about this manual

Ask about setup, troubleshooting, compatibility, parts, safety, or missing instructions. Manuals+ will review the question and use this page’s manual context to help answer it.