1. Introduction
The Aideepen TDS-H1A Water Quality Detection Pen is a portable and accurate device designed to measure the Total Dissolved Solids (TDS) in various water sources. This meter helps you assess the purity of your drinking water, swimming pool water, aquaculture water, and more. Understanding the TDS level is crucial for maintaining water quality and ensuring health.

2. Safety Information
- Keep the device out of reach of children.
- Do not immerse the entire device in water; only the probe should be submerged up to the immersion line.
- Avoid exposing the device to high temperatures or direct sunlight.
- Handle with care to prevent impact or heavy pressure.
- Ensure the battery compartment is sealed properly after battery installation.
3. Package Contents
- 1 x TDS Water Quality Tester
- 1 x Instruction Manual

4. Product Overview
The TDS-H1A features a compact design with an easy-to-read digital display and simple controls.

Key Features:
- Small and Convenient: Easy to store and carry.
- Alloy Electrode Probe: Provides sensitive response and accurate conduction.
- High-Definition Display: Clear LCD screen for easy reading.
- Easy to Use: Fast detection speed.
- Wide Application: Suitable for daily drinking water, swimming pools, aquaculture, agricultural water, and general water quality testing.
5. Specifications
| Parameter | Value |
|---|---|
| Model Number | TDS-H1A |
| Brand Name | Aideepen |
| Display Type | DIGITAL |
| Measuring Range | 0-9990 ppm |
| Working Environment | 0°C - 60°C |
| Product Probe | Alloy probe |
| Product Battery | 2 x 1.5V LR44 Button Battery (Not Included) |
| Product N.W. | 30g |
| Product Size | 140mm x 24mm x 14.5mm (5.51in x 0.94in x 0.57in) |

6. Setup
Battery Installation:
- Locate the sealed removable battery compartment on the top of the device (refer to Figure 3).
- Carefully open the compartment.
- Insert two (2) 1.5V LR44 button batteries, ensuring correct polarity.
- Close the battery compartment securely.
Note: Batteries are not included in the package and must be purchased separately.
7. Operating Instructions
- Turn On: Press the 'ON/OFF' button to power on the device. The display will show '000 ppm'.
- Prepare Sample: Fill a clean container with the water you wish to test.
- Immerse Probe: Remove the protective cap from the probe. Submerge the alloy electrode probe into the water sample, ensuring the water level does not exceed the immersion line (approximately 4cm from the pen tip).
- Read Measurement: Wait for the reading to stabilize on the digital display. The device will automatically compensate for temperature.
- Hold Reading: To lock the displayed value, press the 'HOLD' button. This is useful for recording the measurement after removing the meter from the water.
- Turn Off: Press the 'ON/OFF' button again to power off the device. The meter will automatically shut off after approximately 10 minutes of inactivity to conserve battery life.
- Clean and Store: After use, gently shake off excess water from the probe and replace the protective cap. Store in a cool, dry place.

TDS Value Reference Range:
The following table provides a general reference for water quality based on TDS values. These are based on international direct drinking water standards.
| TDS (ppm) | Water Quality Level | Description |
|---|---|---|
| 0-20 | High purity | Ideal drinking water, safe to drink. |
| 21-50 | General purity | Healthy drinking water, boil it before use. |
| 51-100 | Mineral water | Can be drunk directly after professional treatment. |
| 101-200 | Hard water | Needs to be softened before use. |
| 201-400 | Scale formation | Barely acceptable water for daily life. |
| 401-500 | Poor condition | Poor taste, cannot be used. |
| More than 500 | Large pollution level | Unhealthful. |

8. Maintenance
- Cleaning: After each use, rinse the electrode probe with clean water to remove any residue. Do not use abrasive cleaners or solvents.
- Storage: Always replace the protective cap after use. Store the meter in a cool, dry place away from direct sunlight and extreme temperatures.
- Battery Replacement: If the display becomes dim or the device does not power on, replace the batteries (2 x 1.5V LR44 button batteries).
- Calibration: The device is factory calibrated. If you suspect inaccurate readings over time, you may consider professional calibration or replacement.
9. Troubleshooting
- No Display/Dim Display: Check battery installation. Replace batteries if necessary.
- Inaccurate Readings: Ensure the probe is clean. Make sure the probe is fully immersed up to the immersion line but not beyond. Avoid air bubbles around the probe.
- Readings Constantly Changing: Ensure the water sample is still. Press the 'HOLD' button to lock the reading once it stabilizes.
10. User Tips
- Always have spare LR44 batteries on hand, as they are not included with the device.
- For consistent readings, try to test water samples at a similar temperature.
- If readings fluctuate, ensure the meter is held steady in the water and allow a few seconds for the reading to stabilize before pressing 'HOLD'.
11. Frequently Asked Questions (FAQ)
- Q: What type of batteries does this water tester use?
- A: It uses two (2) 1.5V LR44 button batteries.
- Q: Does this device test pH levels?
- A: No, this device is specifically designed to measure Total Dissolved Solids (TDS) and Electrical Conductivity (EC). It does not test pH.
12. Warranty and Support
This product comes with a standard manufacturer's warranty. For specific warranty terms, technical support, or service inquiries, please refer to the official product page or contact the seller directly. You can also find additional documentation, including a user manual in PDF format, at the following link: TDS-H1A User Manual (PDF).